37
37
7.21 PLU chain(arrangement)
It's possible to link until nine PLU codes to a PLU arrangement that will activate the
callback automatically and also the selling data registration of the PLU linked together to the
same PLU group ; it's possible to create on J3500 until nine PLU chain.
It's possible to insert and to create PLU arrangement that can recall all kinds of PLU's
managed from the ECR (internal PLU and external PLU on the PC).
PLU arrangements, can be recalled by the insertion of the code of the arrangement (from
1 to 9) and the pression of the key "PLU arrangement by code" or by the direct pression of
the key linked to the PLU arrangement "Hard PLU arrangement X" that it is wanted to be
recalled, see also par. 7.1 KEYBOARD LAYOUT CONFIGURATION.
Obviously, like already indicated in the previous page relatively to Hard PLU, than all the
other programmings concerning to the PLU, in case of internal PLU in the ECR's memory, must
be executed like already described in paragraphs 7.15, 7.16 and 7.17.
PLU CODES LINKING TO PLU ARRANGEMENT :
For the next PLU
P
(80X)
X/time
(CCC..C)
PLU
#/NS
KEY
Max. 12 cd
X
= PLU arrangement code (from 1 to 9)
CCC..C = PLU code to link to PLU arrangement (Max. 12 C/D)
Max nine PLUs for each arrangement.
Note :
⇒
it is possible to link to a PLU arrangement all the types of PLU available on
J3500 (internal PLU and external PLU).
⇒
the operation described above links only the PLU's codes to an arrangement
on the ECR, all the programmings eventually concerning to an internal PLU
must be made like described in the previous paragraphs.
⇒
the sequence (CCC..C) PLU can be replaced from the reading through
scanner of the bar-code of the product.
⇒
the registration of a PLU arrangement cannot be cancelled by the pression
of the "E.C." key, it could be only corrected by the use of the keys "VOID" or
"R.M." one PLU at time.
Print form
PLU chain 1
#1
#2
#6
#9
Summary of Contents for J3500E