CAUTION!
The installation must be effected by person-
nel possessing the technical and professional
qualifications required by the national regu-
lations and specifications in force in this field.
The manufacturer declines all liability for
events arising from incorrect installation or
operation of the tub.
The product is designed for indoor use in
bathrooms, and must not be installed in
the open.
Always power off the product (omnipolar
switch in the OFF position) when main-
tenance is to be performed on electrical
components.
The guarantee conditions are listed in the
guarantee certificate.
ELECTRIC
SAFETY
The product is class “I” appliance.
They must be fixed securely and connected
sturdily to the mains and to the earthing and
unipotential systems.
The manufacturer accepts no liability if
the hydraulic and electrical circuits are not
in compliance with EN safety standards.
The building’s electrical circuit must be
in compliance with EN safety standards
and protected by a standards-approved
differential switch (safety cut-out) with a
differential value of 30mA.
The cut-out must be periodically tested for
correct operation.
The earthing system must have a resistance
less than 4 ohm.
The product is provided with an unipotential
attachment terminal suitable for receiving a
6 sq.mm 2.5 cable to be used to obtain the
unipotentiality of the metal masses.
The connection to the electrical mains must
be permanent and made with a cable that is
not lighter than type H05 V V-F tri-polar, with
a nominal section of 3x2.5 mm
2
. It must be
intercepted by an
omnipolar switch
with
opening of contacts of at least 3.5 mm suita-
ble for voltage of at least 230 V and a current
of 16 A. It should if possible be located outside
the room and distant from locations where it
might come into contact with water.
Use the device according to the IP data
indicates:
INSULATING CLASS: CLASS I
IP RATING: IP 44
CONNECTING THE
EQUIPOTENTIAL CIRCUIT
Provide equipotential connection of the
metallic masses extraneous to the shower
booth by using the earth equipotential
contact.
Arrange the cable outlet near the electrical
power supply.
SAFETY RULES
FOR BATHROOMS
Sockets, lights, switches and other electric
devices must be installed outside the danger
zones as laid out by the Laws and interna-
tional standards for bathrooms.
Switches and other electric devices must be
situated in areas that cannot be reached by
the person using the shower booth.
It is strictly prohibited to touch, handle or
switch-on electric appliances while using the
shower booth.
Electrical appliances positioned in the zones
surrounding the product must be securely
fixed in position to prevent them falling into
the product.
THE PRODUCER DECLINES
ANY RESPONSIBILITY IF :
The Laws and national standards regarding
earthing and electric systems for the product
are not respected.
The Laws and national standards in force
regarding safety for bathrooms are not
respected.
The instructions contained in this manual are
not adhered to.
Summary of Contents for Smart Vapour 0015
Page 1: ...Manual for installation and use Smart vapour...
Page 4: ...4 3 17 8 5 0 c m n 4 A B C n 4 n 4 5x50 8 TC 5 2x38 tools kit...
Page 5: ...5 230 V IMPORTANT 5 mm 0 mm XX mm NO NO OK 1 x4 2 3 1 assembly sequence...
Page 6: ...6 2 8 x4 2 1 x4 x4 5x50 TC 5 2x38 2...