background image

JT-200D

JT-315D

No.

Part no

Description

No.

Part no

Description

1

10040581

Summary board

18

10022040

Solenoid value

2

10006625

Silicon bridge

19

10006520

Encoder

3

10020434

Bottom panel

20

10040130

Control board

4

10020604

Arc start board

21

10044448

Front panel

5

10006560

Reactor

22

10044430

Panel overlay (with electro circuit)

6

10020646

Hand switch board

23

10004919

Knob

7

10005295

Glaze resistor

24

10045761

Underneath stick for the front panel

8

10040654

Power transformer

25

10004684

Two pin socket

9

10037776

Secondary driver board

26

10004685

Five pin socket

10

10020665

Secondary power transformer

27

10016390

Water connection

11

10020608

Power transform board

28

10021856

Quick socket

12

10037448

Back Panel

29

10020975

Secondary inverter board A

13

10004935

Power switch

30

10020977

Secondary inverter board B

14

10037303

EMC

31

10040578

Top board

15

10022057

Fan

32

10038699

Central board

16

10016389

Connector for water

33

10020826

Power line

17

10021912

Line button

 

 

 

27

No.

Part no

Description

No.

Part no

Description

1

10014869

Front Panel

17

10020665

Secondary power transformer

2

10038551

Panel overlay

18

10037776

Secondary inverter driver board

3

10040580

Summary board

19

10005305

Glaze resistor

4

10006803

Electric current trans

20

10020809

Power line

5

10004946

Power switch

21

10013302

Back panel

6

10004919

Knob

22

10022039

Solenoid value

7

10021855

Quick Socket

23

10022060

Fan

8

10016390

Water fast socket

24

10020998

Secondary inverter board A

9

10004684

Two pin socket

25

10040579

Top board

10

10001685

Five pin socket

26

10042330

Control board

11

10021002

Arc coil

27

10006520

Encoder

12

10020441

Bottom panel

28

10021912

Line button

13

10006562

Reactor

29

10006625

Silicon bridge

14

10021614

EMC

30

10020997

Secondary inverter board B

15

10020608

Power transform board

31

10039434

Central board

16

10040655

Power transformer

32

10020646

Hand switch board

Summary of Contents for 315P AC/DC Digital

Page 1: ...cleaning width Remote control interface AC function for aluminium and aluminium alloys DC TIG function for carbon steel copper and non ferrous metals Smooth arc and stable welding performance Integrat...

Page 2: ...Operator Manual www jasic co uk TIG Series TIG 200P AC DC Digital JT 200D TIG 315P AC DC Digital JT 315D...

Page 3: ...pplier of equipment in the UK and our products are supported by our extensive service network Call your distributor in the unlikely event of a problem occurring Please record below the details from yo...

Page 4: ...e protection Insulate yourself from work and ground using dry insulating mats or covers big enough to prevent any physical contact with the work ground Never touch the electrode if you are in contact...

Page 5: ...an may cut fingers and hands and snag garments Protections and coverings may be removed for maintenance and controls only by qualified personnel after first disconnecting the power supply cable Replac...

Page 6: ...etwork at the public network connection point must be applied to these systems In this case the installer or the user is responsible for ensuring the equipment can be connected consulting the electric...

Page 7: ...igent digital control so it is not sensitive to the change of parameters of components That is the performance of welding machine will not be a ected by the change of the parameters of certain compone...

Page 8: ...cation protocol Available as a special order Perfect automatic recording function All data such as cumulative start up times cumulative running time cumulative welding time cumulative TIG welding time...

Page 9: ...range MMA A DC 10 200 AC 20 200 DC 10 300 AC 20 300 Arc force current range MMA A 0 100 0 100 Initial current range A DC 10 200 AC 20 200 DC 10 320 AC 20 250 Peak current range A DC 10 205 AC 30 205...

Page 10: ...ch connector 5 Remote control connector 6 Positive power connector 7 Mains switch 8 Adjustment control Front view JT 315D 1 Control panel 2 Negative output socket 3 Torch gas connector 4 Torch switch...

Page 11: ...Data plate 10 Power cable input 11 Shield gas input connector 12 Serial number Rear View JT 315D 9 Data plate 10 Power cable input 11 Water input connector 12 Shield gas input connector 13 Serial numb...

Page 12: ...arameters and users may perform welding conveniently with these parameters C The digital meter displays the software version after the machine is started and displays the pre set current 2 seconds lat...

Page 13: ...least to avoid arc breaking due to overly low current and should not be higher than the pre set current The foot control is e ective only in TIG mode 1 Pre flow time 7 Pilot arc current 2 Initial cur...

Page 14: ...ilable for this machine Concept hints Parameter group 5 parameter groups 1 5 are available for users to save the welding parameters based on a welding application and all parameters in all the six wel...

Page 15: ...erally 1 5 3 times the welding current and the arc ignition time is 0 02 0 05s When in low current ignition mode the arc ignition current is generally 0 2 0 5 times the welding current and the arc ign...

Page 16: ...ng it will lead to a waste of shield gas if it is too short it will result in the oxidation of weld bead and electrode When in AC TIG or for special materials the time should be longer Upslope time tr...

Page 17: ...between 10 and 90 TIG spot welding Select TIG operation mode 1 and TIG spot welding function can be achieved Spot welding is available in all the four TIG welding modes Please note that the spot weld...

Page 18: ...de no Operation Torch trigger operation and current curve 0 Follow mode Push the torch trigger arc is ignited and current rises to the pre set value Release it arc stops 1 1T Spot welding mode Push th...

Page 19: ...again and then turn to If push the torch trigger and release it at once arc will stop 7 Cycle single operation mode with initial current Push the torch trigger arc is ignited and current reaches the i...

Page 20: ...se it current drops to pilot arc current value Push it again arc stops 13 Double operation 3T mode Push the torch trigger arc is ignited and current rises gradually The torch trigger can be released a...

Page 21: ...t again current rises to the preset value and then turn to If push the torch trigger and release it at once or release the torch trigger and push it at once arc will stop Note Preset value is the peak...

Page 22: ...connected to the negative terminal and the work return to the positive terminal MMA welding DC Insert the cable plug with electrode holder into the socket on the front panel of the welding machine and...

Page 23: ...ding to the relevant content in this manual and TIG welding can be carried out The arc ignition mode of this machine is non contact arc ignition During welding the parameter display meter displays the...

Page 24: ...o before opening the case NOTE When the inverter welder is powered on defective components may explode or lead to explosion of other components Wear face guard and long sleeved clothing when maintain...

Page 25: ...th a higher rated current holder MMA Arc is easy to break Arc breaking voltage is too low Increase the arc breaking voltage TIG There is no current output when pushing the torch trigger Welding can be...

Page 26: ...o the power cord which is connected to other electric appliances of serious interference Other malfunction Other malfunction Contact the service centre Type Alarm Automatic response Cause Solution Ove...

Page 27: ...Electrical schematic 7 25...

Page 28: ...Parts list 8 JT 200D 26...

Page 29: ...0040578 Top board 15 10022057 Fan 32 10038699 Central board 16 10016389 Connector for water 33 10020826 Power line 17 10021912 Line button 27 No Part no Description No Part no Description 1 10014869 F...

Page 30: ...JT 315D 28...

Page 31: ...JT 200D JT 315D DIGITAL AC DC PULSE TIG MMA WELDING MACHINE Order code JT 200D JT 315D Wilkinson Star Limited Issue 1 January 2014 Product is subject to change without notice xxix...

Page 32: ...rigger and release it at once Release the torch trigger and push it at once Push the torch trigger twice within 0 5s or Release the torch trigger twice within 0 5s or These are the general description...

Page 33: ...ration stipulations 100 codes are classified and explained in Attached Table 2 based on their functions and characteristics and users should fully understand all those For welding machine operation mo...

Page 34: ...s 100 kinds of operation codes are available for this machine there is more than one code sequence to achieve the specific operation function and users only need to choose one of them It should be str...

Page 35: ...ode with initial current 8 Inner timing operation mode 9 Outer timing operation mode 10 Cycle double operation mode without initial current 11 Cycle double operation mode with initial current 12 Singl...

Page 36: ...quartic operation stop arc 9X Immediate transfer code X 0 Turn to next step X 0 Turn to Step X X 0 9 The definition of order X The definition of order X The definition of order X The definition of or...

Page 37: ...d you can press the parameter display selecting key and the operation mode LED flashes This means you have entered into code editing state Code no selecting and code content editing After you enter in...

Reviews: