Operation
Operation of the remote control
1.
Turn on the welding power source.
2.
W h e n s e t t i n g t h e w e l d i n g
parameters using the remote control
connect the remote control using the
magnetic back plate to the work piece
(work return). Place the end o
ff
the
electrode in contact with the electrode
touch point (point 3 – control layout).The
electrode should remain in contact for
the duration of the process of setting.
3. When contact is made the remote
control power displays "---".
The display will then light, the
current setting will be displayed and
the current indicator LED will be lit.
Remote control operation
1.
On the remote control press the set
button (point 5 – control layout) to
highlight the parameter to be set, either
welding current or arc force (the
parameter will be indicated by either
LED 1 or 2 lit on the control).
2.
The display will show either welding
current or arc force dependent on the
selection
3.
Adjust the value using the plus or
minus buttons to the required value,
shown on the display. When adjusting
the welding current or arc force LED
(dependent on selection) will flash
4.
When adjusting the arc force if no
buttons are pressed within 5 seconds, it
will automatically switch to the current
display state.
5.
When the values are set press the
send button and the digital display "---",
which means that it is in communicating
mode. If the digital re-displays the
current parameter values and the LED
stops flashing, this means that the
communication is completed and data
has been transmitted to the data to the
power source.
6.
If the communication does not work
within 5 second, please re-press the
"Send" button.