Operation of the remote control

1.

 

Turn on the welding power source.

2.

 

W h e n  s e t t i n g  t h e  w e l d i n g 

parameters  using  the  remote  control 
connect  the  remote  control  using  the 
magnetic  back  plate  to  the  work  piece 
(work  return).  Place  the  end  o

  the 

electrode  in  contact  with  the  electrode 
touch point (point 3 – control layout).The 
electrode  should  remain  in  contact  for 
the duration of the process of setting. 

3. When  contact  is  made  the  remote 

control power displays "---". 

The display will then light, the 
current setting will be displayed and 
the current indicator LED  will be lit. 

Remote control operation 

1.

 

On the remote control press the set 

button  (point  5  –  control  layout)  to 
highlight the parameter to be set, either 
welding  current  or  arc  force  (the 
parameter  will  be  indicated  by  either 
LED 1 or 2 lit on the control).

2.

 

The display will show either welding 

current  or  arc  force  dependent  on  the 
selection

3.

 

Adjust  the  value  using  the  plus  or 

minus  buttons  to  the  required  value, 
shown  on  the  display.  When  adjusting 
the  welding  current  or  arc  force  LED 
(dependent on selection) will flash

4.

 

When  adjusting  the  arc  force  if  no 

buttons are pressed within 5 seconds, it 
will  automatically  switch  to  the  current 
display state.

5.

 

When  the  values  are  set  press  the 

send button and the digital display "---", 
which means that it is in communicating 
mode.  If  the  digital  re-displays  the 
current  parameter  values  and  the  LED 
stops  flashing,  this  means  that  the 
communication  is  completed  and  data 
has been transmitted to the data to the 
power source.

6.

 

If the communication does not work 

within  5  second,  please  re-press  the 
"Send" button. 

4

Summary of Contents for Arc 401

Page 1: ...wilkinsonstar com Arc 401 Wireless remote control Order code JA WRC OPERATOR MANUAL ...

Page 2: ...ote control cables The system uses the electrode lead and work return lead to send the data from the control to the power source The digital meter displays the welding current and arc force seHngs so that the operator can accurately pre set welding parameters The remote control needs no addi onal power supply The remote control is small light weight simple to operate easy to carry with excellent p...

Page 3: ...cates display is showing welding current 2 Indicates display is showing arc force setting 3 Electrode touch point 4 Adjustment minus button 5 Selection button 6 Adjustment plus button 7 Send button 8 Digital display Control panel layout ...

Page 4: ... point 3 control layout The unit provides a modulated carrier signal The power source contains a receiving circuit for receiving and demodulating the modulated signal and then the demodulated signal is converted to the desired welding parameter so that welding can be carried out according to these adjusted parameters The carrier signal has a high immunity to interference 3 ...

Page 5: ... be set either welding current or arc force the parameter will be indicated by either LED 1 or 2 lit on the control 2 The display will show either welding current or arc force dependent on the selection 3 Adjust the value using the plus or minus buttons to the required value shown on the display When adjusting the welding current or arc force LED dependent on selection will flash 4 When adjusting ...

Page 6: ...ng can now take place Power failure or shutdown This product has parameter memory function Parameter settings are automatically stored even when the power is disconnected or the remote control removed Upon restoration of the power the last adjusted parameters will be stored ready for welding 5 ...

Page 7: ...xceed 90 Ambient temperature should be between 10C to 40C Do not let the water penetrate into the remote control Avoid use in dusty areas or corrosive atmospheres When using the remote control at high levels ensure that it is secured to prevent falling to avoid injury Avoid connection to a work piece with a temperature higher than 100 Over voltage The remote control must be used within the require...

Page 8: ...Wireless remote control Order code JA WRC Wilkinson Star Limited Issue 1 April 2014 Product is subject to change without notice vii ...

Reviews: