25
EC2 to adjust parameters
value
W1 to display parameter No. W2 to display parameter value
2
3
Fig 5.6
5.3.2 Other internal parameters:
Backend parameter mode where calibration of current and voltage, VRD and cooler switch are available can be
activated when this machine is switched on. Below are steps:
1
、
Press K2 button on the panel to switch power on, segment display W1 shows “001”, W2 shows “CAL” and
K2 can be released;
2
、
At this time, segment display W1 shows “P01”, representing “parameter 1”, while segment display W2
shows the value of “parameter 1”;
3
、
Pressing K1 can switch parameters in order, rotate encoder EC2 to adjust current parameters, press K2 to
save and exit.
Fig 5.7
Table 5-4 Backend parameters table
Paramet
er No.
Parameter definition
Parameter value
Remark
P1
Actual current calibration
Please do
not change!
P2
Display current calibration
P3
Display voltage calibration
P4
Actual voltage calibration
K2 to activate backend and save
K1 to switch parameter No.
1