15
1
0
MIG
operation
mode
selection
area
○
,1
spot welding
○
,2
2T
○
,3
4T
○
,4
Special 4T
○
,5
operation mode selection key K8
1
1
Gas
detection
key and
indicator
K8 self-locking gas detection: one press and
there is gas, also indicator will light up; gas
will stop entering automatically after 20s. If
press again within 20s, it will stop sending
gas.
1
2
Wire feed
key and
indicator
K10 self-locking wire feeding: one press and
indicator will light up; start wire feeding by
pressing wire feed speed; press again and
indicator will light off and it will stop wire
feeding.
5.2 Function description
Warning! Select welding function complies with demands. Select the method according
to the technological requirements of workpiece during the welding, if selects the
method improperly, unstable electric arc, large splash and sticky welding rod may
occur.
5.2.1 Parameters set
“JOB No.” refers to storage and invocation of parameters set, which can store 20 sets of parameters “0~19”. The
parameters set has priority over any other parameter because it includes all parameters that can be set by welder panel
such as welding modes and all states and parameters setting in welding mode. Each parameter adjusted will be
automatically saved in the current applied parameters set, therefore parameters of this parameters set are still the same
as last time when you turn on the machine next time. This machine is not installed specialized memory key as well as
manual storage or invocation.
Parameters set is easy-operated, because it can be switched by encoder EC2 with indicator of “parameters set” on by
pressing parameters switching key K2. By switching parameters set, corresponding parameters will show up and will
be saved automatically if they are adjusted.
①
②
③
④
⑤
Summary of Contents for MIG 350P
Page 13: ...11 4 6 2 Separated machine installation Figure 4 3 ...
Page 19: ...17 3 Operation modes Table 5 2 DC MIG operation modes Modes Sketch map 2T 4T ...
Page 20: ...18 Repeat Spot weldin g 5 2 3 Pulse MIG 1 Synergic and Separate ...
Page 22: ...20 2T with initial crater 4T ...
Page 23: ...21 4T with initial segmen t Special 4T pro gram 4T ...
Page 40: ...38 7 Wiring Diagram ...
Page 42: ...40 ...