INSTALLATION INSTRUCTIONS (cont.)
PreMIer eDITIOn MICrOsIlK
®
Jason’s Premier Edition MicroSilk
®
system incorporates all
the features of the Standard Edition system and includes
the benefits of an ozone sanitation system and an LED
Chromatherapy light kit. To assure that your bath func-
tions properly, the MicroSilk
®
control box must be properly
connected.
NOTE: For 120V systems, the power cord for the
MicroSilk
®
control box must be plugged into a 120V,
20 amp, GFCI dedicated circuit.
NOTe:
This diagram also applies to 50 Hz, 240V pumps, controls,
and power supply systems. Except that the MicroSilk
®
Pump
junction boxes must be connected into one dedicated 240V, 20
amp, GFCI circuit.
Figure 19
IMC-263
MS Premier 2014
A
To Dedicated
120V / 60Hz 20A
GFCI Protected Service
C
C
D
D
B
Ozone
MS
Pump
LEDs
Keypad
Control Box
The MicroSilk
®
Control Box
The MicroSilk
®
unit, keypad, LED light, and Ozone Sanita-
tion Unit must be plugged into the proper receptacles for
correct operation of the MicroSilk
®
system. See Figure 19
for connections:
(A) The power cord for the MicroSilk
®
control box must be
connected into the proper GFCI dedicated circuit for the
system (see note).
(B) The MicroSilk
®
pump’s power cord should be plugged
into the female cord connection on the ozone unit, prewired
to the control box.
(C) Eight-pin mini-DIN terminal for the MicroSilk
®
Keypad.
(D) Six-pin mini-DIN terminal for LED light.