Jason International, Inc. •
501.771.4477
Page 22 of 26
Customer Service : 800.255.5766
Copyright © 2014 Jason International, Inc.
OPeraTIng InsTruCTIOns
MicroSilk
®
On/Off Icon
To control the operation of the MicroSilk
®
unit, press and re-
lease for each setting: ON or OFF. A 20-minute decreasing
timer will be initiated when the pump motor starts. Press and
hold the MicroSilk
®
icon to cycle through each pump setting.
The MicroSilk
®
icon lights when the water is at operating level
and the LCD displays “System Ready”. The LCD will display
“MS On”, or “MS Off” when the key is pressed. It also toggles
between Temperature and Timer at 5 second intervals. “Low
Water” is displayed for 5 seconds if no water is detected.
LED Light Icon
Hold the key for less than two (2) seconds to turn the lights
Off or On. Hold the key for more than two (2) seconds to
change modes. The Light icon should remain lit as long as
the bath is connected to a power supply. This function has
a two-hour timer and remembers the last mode. The LCD
displays “Light On” or “Light Off” while the key is pressed
for less than two (2) seconds, “Light Cycle” is displayed if
pressed for more than two (2) seconds.
Customized Settings
The 12-character LCD display can be customized by pressing
the two Diagnostic Function icons simultaneously for five (5)
seconds, while the system is off. Note: Use the above figure
to locate the icons. A menu will be displayed to choose the
following: Product Test Diagnostics, Temperature (°F or °C)
and Language (English or Spanish).
Menu Instructions
Use the top Diagnostic Function icon to scroll through the
different menu items. Use the bottom Diagnostic Function
icon to change an option. For example, press and release
the top icon to change from Product Test to the Temperature
option. Press and release the bottom icon to change the
temperature display from °F (Fahrenheit) to °C (Celsius).
Product Test Diagnostics
After selecting the Product Test option from the menu, the unit
will perform a series of tests to confirm correct installation of
components. The test will begin by displaying the configuration
number, followed by the software revision number. Next, the
display will then test the Temperature and Low Water level
sensor (ITW-209). Next, each of the six (6) icon buttons will
begin to light. Press the illuminated button to proceed to the
next icon. After the icon test, the LED Light unit will be tested.
If you receive an error on any of the tests, confirm proper
installation of component to the correct control box. (See the
CONTROL BOX CONNECTIONS section).
Remote Control
The Signature Edition control system includes a waterproof
floating Universal Remote Control. It controls all bath functions
plus a TV, DVD, CD, etc., which can be heard through the
Sound Immersion Transducers (optional).
SIGNATURe eDITION mICROSILK
®
TOUChPAD
Figure 24
m
IR for Remote
LED Light
For Diagnostic Functions
For Diagnostic Functions
MicroSilk
®
On/Off
opERAtInG InStRUCtIonS, FEAtURES, AnD ContRolS (cont.)