4. AirMasseur
®
Equipment
The AirMasseur
®
equipment may be shipped separately
from the bath. The blower is prewired to the control box.
The control box has a 36" (91cm) cord with plug end (junc-
tion box connection for 240V). The blower control box is
mounted on a stand. During installation, the control box
stand and controls must be positioned horizontally and
located to permit access for inspection and servicing.
INSTALLATION INSTRUCTIONS (cont.)
120V Electrical Service - AirMasseur
®
Control Box.
The blower control box must be plugged into a dedicated
120V, 15A, 60Hz, GFCI protected circuit. See Figure 9.
240V Electrical Service - AirMasseur
®
Control Box
(Export). The blower control box must be plugged into a
dedicated 240V, 15A, 50 or 60 Hz, GFCI protected circuit.
See Figure 9.
Control Box
Light Cable
Check Valve
Blower
Blower Mount
Keypad Cable
Ground - Green Wire
Neutral - White Wire
Hot - Black Wire
Dedicated
120V, 50 or 60 Hz
GFCI Protected
Service
L2
L1
GROUND
DEDICATED
240V,50 or 60 Hz
GFCI PROTECTED
SERVICE
NOTE: USE THE ABOVE
DIAGRAM FOR 240V, 50Hz
OR 60Hz SYSTEMS.
Figure 9
AirMasseur
®
Floor Installation
Figure 9a
AirMasseur
®
Below floor installation
O
R
Standard / Premier
Edition
Signature
Edition
Control Box
Light Cable
Keypad Cable
Low Water/Temp Cable
(Signature Edi
ti
on)
Check Valve
Blower
Blower Mount
Ground - Green Wire
Neutral - White Wire
Hot - Black Wire
Dedicated
120V, 50 or 60 Hz
GFCI Protected
Service
L2
L1
GROUND
DEDICATED
240V,50 or 60 Hz
GFCI PROTECTED
SERVICE
NOTE: USE THE ABOVE
DIAGRAM FOR 240V, 50Hz
OR 60Hz SYSTEMS.