5. MicroSilk Equipment
The MicroSilk equipment will be shipped separate from
the bath with the AEC Equipment Cabinet. Follow the
instructions for the AEC EQUIPMENT CABINET INSTAL-
LATION section of this owner’s manual. The control box
has a 36" (91cm) cord with plug end (junction box con-
nection for 240V). The MicroSilk control box is mounted
on a stand.
120V Electrical Service MicroSilk
®
Control Box. The
MicroSilk control must be plugged into a dedicated 120V,
20A, 60Hz, GFCI protected circuit. See Figure 10.
INSTALLATION INSTRUCTIONS (cont.)
240V Electrical Service - MicroSilk
®
Control Box. The
MicroSilk control must be plugged into a dedicated 240V,
15A, 60Hz, GFCI protected circuit. See Figure 10.
DANGER: Do not alter the factory installed wiring.
All building materials and wiring should be routed
away from the equipment or other heat-producing
components of the unit.
Figure 10
Control Box
Dedicated
120V, 50 or 60 Hz
GFCI Protected
Service
Ground
L2
L1
Dedicated
240V, 50 or 60 Hz
GFCI Protected
Service
L2
L1
GROUND
DEDICATED
240V,50 or 60 Hz
GFCI PROTECTED
SERVICE
NOTE: USE THE ABOVE
DIAGRAM FOR 240V, 50Hz
OR 60Hz SYSTEMS.
Control Box
Ground - Green Wire
Neutral - White Wire
Hot - Black Wire