background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 1 of 16

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2011 Jason International.

49-1012-201

Date    04/11

“TO BE REMOVED FOR USE BY THE OCCUPANT.”

Jason International, Inc.

 

8328 MacArthur Drive

North Little Rock, AR 72118
www.jasoninternational.com

OWNER’S RECORD

Dealer: 

Date Purchased: 

Date Installed: 

Installer: 

PlaCE SERIal NumbER CaRD WIth 

PRODuCt CONfIguRatION IN thIS bOx

OWNER’S maNual

ma635P Designer airmasseur

®

 baths

INStallatION, OPERatION, aND maINtENaNCE

INSPECtION

Inspect the unit prior to installation. In the event of a 

problem, DO NOT install the unit.

  

All components are factory assembled to the bath and the 
unit is water tested and inspected prior to leaving Jason 
International, Inc.

If the carton shows sign of damage, inspect the product 
before accepting and describe the problem on the Bill of 
Lading.

NOTe: Transportation and insurance from Jason’s 

factory are the buyer’s responsibility.

Damage sustained in transit is the responsibility of 

the carrier.

 If damage is discovered, the carrier must 

be immediately notified in writing with a request for a 
representative to inspect the unit. Failure of the carrier 
to respond should be reported to the seller and carrier. 
Always file a freight claim promptly.

The installer is responsible for insuring that the unit is 
free from defects or shipping damage. In the event of a 
problem, DO NOT install the unit. 
Jason International is not responsible for damage that 
might have been avoided by inspection or testing prior to 
installation.

If  the  carton  shows  sign  of  damage,  inspect 

the product before accepting and describe the 

problem on the bill of lading.

Damage to the unit during installation will not be covered 
by warranty and is the responsibility of the installer. ALL 
WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE 
MUST BE MADE PRIOR TO INSTALLATION. Inspect 
plumbing and bath surface for missing or damaged 
components. Alert your dealer of any discrepancies.

To protect the unit from damage keep the bath in the 
carton until ready for installation.

EQuPmENt aCCESS

In accordance with Building Codes, service access 
to all therapy bath equipment, controls and electrical 
connections must be provided during installation 

(see 

Table 1 - Specifications for minimum access size).

Insufficient access will hinder repair and maintenance. 
Warranty Service

Summary of Contents for AirMasseur Madeline MA635P

Page 1: ... in writing with a request for a representative to inspect the unit Failure of the carrier to respond should be reported to the seller and carrier Always file a freight claim promptly The installer is responsible for insuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been...

Page 2: ...nd skirt center lines Tape the template to the sub floor in its desired location 6 Markonthesub floor the sump area location the water inlet stub outlocation andtheremoteblower tubingfloorcutout location Two remote blower tubing floor cutout locations and water inlet stub out locations have been indicated on the template Choose the one that is preferable for your installation 7 Removethetemplatean...

Page 3: ...AUTION Only dry fit the drain and overflow tee to the P trap at this time c Disconnect the drain and overflow from the bath and leave the drain assembly free standing in the P trap 12 Align the drain with the centerline on the template See Figure 4 13 Permanently attach the drain tee to the P trap 14 Remove the template from the floor 15 Place the bath skirt into position and attach to the floor b...

Page 4: ... overhang into the well of the bath This will insure an unobstructed water flow out of the faucet when filling the bath Follow the faucet manufacturers installation instructions REMOTE MOUNTING of air blower Do not remote mount the blower and control box more than 15 feet 457 cm away from the air inlet of the bath Choose a location as close as possible to the bath to assure maximum efficiency 1 Th...

Page 5: ...les back up through the floor cutout When installing on a cement slab a conduit may be used if desired to run the cable from the bath to the control box This will allow the bath to be lifted and removed from the skirt if access is required in the future During installation if it is preferred to run the blower hose on top of the floor a 2 1 2 6 35 cm diameter hole can be drilled in the toe kick are...

Page 6: ...f the bath s Level Form Base must be level with the bottom of the skirt Note Do not use a sand bed to install or level the bath 9 Bolts a Startwithone 1 boltandliftthebathenoughtopartially install the bolts Do not tighten the bolts completely at this time Align the bolts with the slot in the bath bracket Repeat the process until all six 6 bolts are partially installed b Continue to fully tighten a...

Page 7: ... CODES MUST BE OBSERVED Where there are no local codes the National Electric Code NEC and Uniform Plumbing Code UPC shall be observed It is the responsibility of the installer owner to determine specific code compliance prior to installation of the product NOTE In the Commonwealth of Massachusetts installation is to be done by a Massachusetts licensed plumber Standard Premier Edition Control Box 1...

Page 8: ... acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks Before water testing the bath 1 make sure any pump unions are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the...

Page 9: ...0v systems the power cord for the Blower control box must be plugged into a 120v 15 amp GFCI dedicated circuit NOTE This diagram Figure 12 also applies to 50 Hz 240v controls and power supply systems Except that the Blower junction box must be connected into one dedicated 240v 15 Amp GFCI circuit NOTE This diagram Figure 13 also applies to 50 Hz 240v controls and power supply systems Except that t...

Page 10: ...d the blower will start again for a two minute purge cycle that dries the air channel Note that the blower light will flash during the 15 minute pause before the purge cycle begins Once the purge cycle begins all indicators will light and the keypad operation will be disabled for two 2 minutes SIGNATURE EDITION AIRMASSEUR The Jason Signature Edition AirMasseur bath includes a variable speed 1 HP a...

Page 11: ...ivating this setting Signature Remote Control In addition to the main control touchpad installed on the bath deck a floating waterproof Universal Remote Control is provided with all Signature Edition AirMasseur baths This remote control provides the same control functions as the bath s main control console plus the bather may remotely operate a TV DVD VCR CD etc Refer to the Instruction Manual pro...

Page 12: ...l LED light if installed Press the icon for less than two 2 seconds to turn the lights Off or On Hold the icon for more than two 2 seconds to change modes This function has a two 2 hour timer and remembers the last mode OPERATING INSTRUCTIONS FEATURES AND CONTROLS cont OPERATING INSTRUCTIONS AirMasseur Icon The AirMasseur icon is used to activate the blower and the 20 minute timer Pressing the Ico...

Page 13: ...NNECTIONS section Remote Control The Signature Edition control system includes a waterproof floatingUniversalRemoteControl Itcontrolsallbathfunctions plus a TV DVD CD etc which can be heard through the optional Sound Immersion Transducers optional Blower On Off Modes Blower Speeds LED Light IR for Remote OPERATING INSTRUCTIONS FEATURES AND CONTROLS cont OPERATING INSTRUCTIONS Blower On Off and Mod...

Page 14: ...erial number proof of purchase andmodelnumber Thiswillinsureaquickresponse on warranty items The serial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment HUMIDITY Warning Avoid high humidity levels in your home Mold mildew fungi and bacteria which maybeharmfultohealththriveinareaswith continued high humidity levels th...

Page 15: ...FCI tripped b Refer to installer dealer Circuit breaker trips repeatedly a Defective breaker a Replace breaker b Short circuit between bath and blower breaker box b Refer to installer dealer c Other items are connected to the same circuit c Refer to installer dealer Blower does not shut off a Defective keypad or timer a Refer to installer dealer Replace keypad or control Air bath does not function...

Page 16: ...h the possibility of drowning Never use the therapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication...

Reviews: