background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 10 of 16

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2011 Jason International.

OPERATING INSTRUCTION, FEATURES, ANd CONTROLS

INTROdUCTION

This  manual  contains  all  information  needed  for  the  proper 
installation  and  operation  of  your  Jason  AirMasseur

®

  bath. 

The AirMasseur

®

 bath has been designed to give you years of 

relaxing trouble-free service, provided the unit is maintained 
and operated in accordance with these instructions.

Thoroughly clean and disinfect the unit as described in the 

ClEaNINg

  section  of  the 

uSER maINtENaNCE INStRuCtIONS 

 

section  of  this  owner’s  manual  before  its  first  use  and 
periodically thereafter.

All Jason air baths are pre-plumbed at the factory.

WaRNINg: before operating refer to the instructions pertaining to the 

risk of fire, electric shock, or injury to persons.

FEAtURES AnD ContRolS

STANdARd ANd PREMIER EdITION AIRMASSEUR

®

 

The  Jason  Standard  Edition  AirMasseur

®

  bath  includes  a 

variable-speed, 1-HP air blower with heater, automatic purge 
cycle; and three (3) massage modes: Continuous, Wave, or 
Pulse; an electronic control; and a 20-minute timer.

The Jason Premier Edition AirMasseur

®

 bath provides all the 

features of the Standard Edition with the included benefits of 
a LED Chromatherapy Mood Light, and an Ozone Sanitation 
system.

Standard/Premier Touchpad

One main control touchpad mounted on the bath deck contains 
several icons used by the bather to control the blower, and LED 
mood light. A built in timer shuts the blower off 20 minutes after 
being activated.

Standard/Premier Automatic Purge

Fifteen (15) minutes after the control has shut off and the bath is 
completely drained, the blower will start again for a two-minute 
purge cycle that dries the air channel. Note that the blower light 
will flash during the 15-minute pause before the purge cycle 
begins. Once the purge cycle begins, all indicators will light and 
the keypad operation will be disabled for two (2) minutes.

SIGNATURE EdITION AIRMASSEUR

®

The  Jason  Signature  Edition  AirMasseur

®

  bath  includes  a 

variable-speed, 1-HP air blower with heater, automatic purge 
cycle; and three (3) massage modes: Continuous, Wave, or 
Pulse; Chromatherapy mood light, Automatic Ozone System 
that will be operated any time the blower is powered; a digital 
control with LCD display window; low water and temperature 
sensors; and a 20-minute timer.

SIGnAtURE EDItIon AIRMASSEUR

®

Jason’s Signature Edition AirMasseur

®

 system is the most 

advanced bath manufactured by Jason International, Inc. 
and features the ultimate in luxury bathing for the leisure 
bath industry. The blower control box must be properly 
connected for the bath to function correctly. 

THE BLOwER CONTROL BOX

The blower, keypad, LED light, ozone sanitation unit, and 
water level/temperature sensor must be plugged into the 
proper receptacle for correct operation of the AirMasseur

®

 

system. See 

Figure 14

 for connections: (A) The junction box 

for the blower control box must be connected into a 240v, 15 
amp GFCI dedicated circuit. (B) Pre-wired power cords to 
blower (C) and ozone unit (G). Eight-pin mini-DIN terminal 
for installation of AirMasseur

®

 keypad (F). Six-pin mini-DIN 

terminals for the water/temperature sensor (D), and LED 
light (E) to the blower control box.

SIGNATURE EdITION AIRMASSEUR

®

 PARTS LIST

Blower   

 

Blower Control Box 

 

 

Keypad  

 

Keypad Cable   

 

 

Control Box Stand 

Water Level/Temp Sensor 

 

LED Light Assembly 

LED Light Cable 

 

 

Ozone Sanitation Unit

Figure 14

NOTE: This diagram (Figure 14) also applies to 50Hz, 240V 

controls, and power supply systems.

Summary of Contents for AirMasseur Madeline MA635P

Page 1: ... in writing with a request for a representative to inspect the unit Failure of the carrier to respond should be reported to the seller and carrier Always file a freight claim promptly The installer is responsible for insuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been...

Page 2: ...nd skirt center lines Tape the template to the sub floor in its desired location 6 Markonthesub floor the sump area location the water inlet stub outlocation andtheremoteblower tubingfloorcutout location Two remote blower tubing floor cutout locations and water inlet stub out locations have been indicated on the template Choose the one that is preferable for your installation 7 Removethetemplatean...

Page 3: ...AUTION Only dry fit the drain and overflow tee to the P trap at this time c Disconnect the drain and overflow from the bath and leave the drain assembly free standing in the P trap 12 Align the drain with the centerline on the template See Figure 4 13 Permanently attach the drain tee to the P trap 14 Remove the template from the floor 15 Place the bath skirt into position and attach to the floor b...

Page 4: ... overhang into the well of the bath This will insure an unobstructed water flow out of the faucet when filling the bath Follow the faucet manufacturers installation instructions REMOTE MOUNTING of air blower Do not remote mount the blower and control box more than 15 feet 457 cm away from the air inlet of the bath Choose a location as close as possible to the bath to assure maximum efficiency 1 Th...

Page 5: ...les back up through the floor cutout When installing on a cement slab a conduit may be used if desired to run the cable from the bath to the control box This will allow the bath to be lifted and removed from the skirt if access is required in the future During installation if it is preferred to run the blower hose on top of the floor a 2 1 2 6 35 cm diameter hole can be drilled in the toe kick are...

Page 6: ...f the bath s Level Form Base must be level with the bottom of the skirt Note Do not use a sand bed to install or level the bath 9 Bolts a Startwithone 1 boltandliftthebathenoughtopartially install the bolts Do not tighten the bolts completely at this time Align the bolts with the slot in the bath bracket Repeat the process until all six 6 bolts are partially installed b Continue to fully tighten a...

Page 7: ... CODES MUST BE OBSERVED Where there are no local codes the National Electric Code NEC and Uniform Plumbing Code UPC shall be observed It is the responsibility of the installer owner to determine specific code compliance prior to installation of the product NOTE In the Commonwealth of Massachusetts installation is to be done by a Massachusetts licensed plumber Standard Premier Edition Control Box 1...

Page 8: ... acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks Before water testing the bath 1 make sure any pump unions are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the...

Page 9: ...0v systems the power cord for the Blower control box must be plugged into a 120v 15 amp GFCI dedicated circuit NOTE This diagram Figure 12 also applies to 50 Hz 240v controls and power supply systems Except that the Blower junction box must be connected into one dedicated 240v 15 Amp GFCI circuit NOTE This diagram Figure 13 also applies to 50 Hz 240v controls and power supply systems Except that t...

Page 10: ...d the blower will start again for a two minute purge cycle that dries the air channel Note that the blower light will flash during the 15 minute pause before the purge cycle begins Once the purge cycle begins all indicators will light and the keypad operation will be disabled for two 2 minutes SIGNATURE EDITION AIRMASSEUR The Jason Signature Edition AirMasseur bath includes a variable speed 1 HP a...

Page 11: ...ivating this setting Signature Remote Control In addition to the main control touchpad installed on the bath deck a floating waterproof Universal Remote Control is provided with all Signature Edition AirMasseur baths This remote control provides the same control functions as the bath s main control console plus the bather may remotely operate a TV DVD VCR CD etc Refer to the Instruction Manual pro...

Page 12: ...l LED light if installed Press the icon for less than two 2 seconds to turn the lights Off or On Hold the icon for more than two 2 seconds to change modes This function has a two 2 hour timer and remembers the last mode OPERATING INSTRUCTIONS FEATURES AND CONTROLS cont OPERATING INSTRUCTIONS AirMasseur Icon The AirMasseur icon is used to activate the blower and the 20 minute timer Pressing the Ico...

Page 13: ...NNECTIONS section Remote Control The Signature Edition control system includes a waterproof floatingUniversalRemoteControl Itcontrolsallbathfunctions plus a TV DVD CD etc which can be heard through the optional Sound Immersion Transducers optional Blower On Off Modes Blower Speeds LED Light IR for Remote OPERATING INSTRUCTIONS FEATURES AND CONTROLS cont OPERATING INSTRUCTIONS Blower On Off and Mod...

Page 14: ...erial number proof of purchase andmodelnumber Thiswillinsureaquickresponse on warranty items The serial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment HUMIDITY Warning Avoid high humidity levels in your home Mold mildew fungi and bacteria which maybeharmfultohealththriveinareaswith continued high humidity levels th...

Page 15: ...FCI tripped b Refer to installer dealer Circuit breaker trips repeatedly a Defective breaker a Replace breaker b Short circuit between bath and blower breaker box b Refer to installer dealer c Other items are connected to the same circuit c Refer to installer dealer Blower does not shut off a Defective keypad or timer a Refer to installer dealer Replace keypad or control Air bath does not function...

Page 16: ...h the possibility of drowning Never use the therapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication...