Jason International, Inc. •
501.771.4477
Page 4 of 16
Customer Service : 800.255.5766
Copyright © 2011 Jason International.
CautION:
There is not enough room to mount a deck
mounted diverter valve on the deck of the bath. If a
hand-held shower is desired, consider a floor mounted
faucet or a faucet with an above deck diverter.
18.
flex Plumbing
a. Place two 2” x 4” (5 cm x 10 cm) boards approximately
four (4) feet (122 cm) in length across the top of the
skirt.
b. Set the bath on top of the 2” x 4” (5 cm x 10 cm)
boards.
c. Attach stainless steel flex plumbing from the deck-
mounted faucet to the stubouts (if applicable).
Flex
plumbing lines must be long enough so the bath can
be removed from the skirt if access is required in the
future.
1/2” (12 mm) four (4) foot (122 cm) stainless steel flex
hoses may be purchased from Jason International,
Inc.
Figure 6
19. Test all connections for leaks.
(See figure 6.)
If a floor mounted faucet is desired, be sure to install
the faucet to allow for sufficient overhang into the well
of the bath. This will insure an unobstructed water flow
out of the faucet when filling the bath. Follow the faucet
manufacturers installation instructions.
REMOTE MOUNTING OF AIR BLOwER
Do not remote mount the blower and control box more than
15 feet (457 cm) away from the air inlet of the bath. Choose a
location as close as possible to the bath to assure maximum
efficiency.
1. The installer is to
determine the layout
of the piping, exact
remote mount location, and service access before
beginning any work.
Use 1.5” (38 mm) ABS or PVC plastic tubing. Locate
the control box with the blower in an area accessible for
servicing.
To insure proper functioning of the system, avoid remote
mounting in a location which requires more than six (6)
piping direction changes. A 90° direction change should
be made up of two 45° elbows for maximum efficiency.
2.
Install the blower and control box in the remote location.
A
minimum ventilation opening of 2” x 4” (5 cm x 10 cm) for
the blower is required, and should be designed to draw in
indoor ambient air at a minimum of 72°F (22°C). Attach
the blower mount firmly to the floor.
INSTALLATION INSTRUCTIONS (cont.)