background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 12 of 18

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2011 Jason International.

 

Never operate the system without the pre-filter, internal 

filter screen and suction cover installed.

blower

The blower generates warm air and pushes it through the air 
jets. Blowers provided on Jason AirMasseur baths are factory 
tested when assembled and again retested after installation 
on the bath.

standard Edition Automatic purge

Fifteen  (15)  minutes  after  the  control  has  shut  off  and  the 
bath is completely drained, the blower will start again for a 
two0minute purge cycle that dries the air channel. Note that 
the blower light will flash during the 15-minute pause before 
the  purge  cycle  begins.  Once  the  purge  cycle  begins,  all 
indicators will light and the keypad operation will be disabled 
for two (2) minutes.

signature Edition Automatic purge

Twenty  (20)  minutes  after  the  control  has  shut  off  and  the 
bath is completely drained, the blower will start again for a 
two minute purge cycle that dries the air channel. Note that 
the LCD display will read “PURGE” and begin to countdown 
the 10 or 20 minute pause before the purge cycle begins. The 
readout will display “PURGE ON” during the purge cycle. Any 
time during the pause before the purge cycle begins, pressing 
and holding the Blower Speeds icon will reduce the pause 
from 20 minutes to 10 minutes. During the two-minute purge, 
pressing the “Blower On/Off” icon will stop the purge.

 

signature Edition Daily purge

The  daily  purge  can  be  activated  through  the  customized 
settings of the Signature Edition touchpad. When activated, 
the  daily  purge  will  start  the  blower  for  two-minutes  at 
the  same  time  every  day  to  dry  the  air  channel.  See 
“Operating  the  Signature  Edition  MicroSilk  AirMasseur 
Touchpad”  section  for  details  on  activating  this  setting. 

Filling And Draining

Close  the  drain  and  fill  the  bath  with  water  at  least  two 
(2)  inches  (50mm)  above  the  jets.  The  inlet  temperature 
should  not  exceed  40

o

C  (104

o

F)  as  this  could  damage 

the  acrylic  surface.  When  bath  is  in  use,  turn  the  unit  Off 
before  draining  the  water.  The  bath  unit  and  its  plumbing 
are  designed  to  drain  after  each  use  whether  used  as  a 
hydrotherapy  bath,  soaking  bath,  or  just  taking  a  shower.

 

 

OpERAting instRuctiOns, FEAtuREs, AnD cOntROLs (cont.)

NOTe: If the unit fails to operate, check the breaker panel 

to insure that the circuit breaker is on. Check the GFCI by 

testing and resetting it. Also check the water level in the 

bath; it must be above the water level sensor located on 

the sidewall of the bath for the pump to operate. If the unit 

still fails to operate, refer to the Trouble Shooting Guide 

section  on  page  15  of  this  manual.  If  the  unit  still  fails 

to operate and is out of warranty, contact an authorized 

service  technician  for  repair.  If  the  unit  is  within  the 

warranty  period,  contact  JASON  Technical  Services  at 

800-255-5766.  DO  NOT  ATTeMpT  TO  ReSOlve  The 

pRObleM.

Summary of Contents for BY630

Page 1: ...s responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered If the carton shows sign of damage inspect the product before accepting and describe the prob...

Page 2: ...cm 236 66 x 36 x 20 5 39 36 x 17 in 47 4 168 x 91 x 52 148 91 x 43 cm 231 72 x 36 x 20 5 45 36 x 17 in 47 6 183 x 91 x 52 170 91 x 43 cm 232 60 x 42 x 20 5 49 36 x 17 in 43 5 152 x 107 x 52 185 91 x 4...

Page 3: ...oor or the skirt will not fit properly 100 Silicone with mildew resistant properties should 2 be applied between the water resistant backer board and the deck of the bath NOTE If you use a tile flange...

Page 4: ...hanges A 90 direction change should be made up of two 45 elbows for maximum efficiency If the blower has been factory installed disconnect the 2 blower from the air bath plumbing by removing the two 2...

Page 5: ...lconnectionsonthedischargeside are tight See Figure 7 Assure the MicroSilk Jet Flex Hose will allow proper drainage to the jets All hoses must haveacontinuousdropfromthesaturationtanktothejets Note Ve...

Page 6: ...er is prewired to the control box The control boxes have a 36 91cm cord with plug end The MicroSilk and blower control boxes are mounted on a stand that is temporarily secured to the packing board for...

Page 7: ...ctoryinstalledwiring Allbuilding materialsandwiringshouldberoutedawayfromtheequipment or other heat producing components of the unit Figure 9 Figure 9A NOTE The load neutral terminal is not used There...

Page 8: ...acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing test...

Page 9: ...RMASSEUR Jason s Premier Edition MicroSilk AirMasseur system incor porates all the features of the Standard Edition system and includesthebenefitsofanozonesanitationsystem andanLED Chromatherapylight...

Page 10: ...ensor must be plugged into the proper receptacle for correct operation of the MicroSilk AirMasseur system See Figure 12 for connections A The junction box for the MicroSilk blower control boxes must b...

Page 11: ...r blower with heater and three 3 massage modes Continuous Wave or Pulse The system also includes a Chromatherapy mood light Automatic Ozone System that will be operated any time the blower is powered...

Page 12: ...es to 10 minutes During the two minute purge pressing the Blower On Off icon will stop the purge Signature Edition Daily Purge The daily purge can be activated through the customized settings of the S...

Page 13: ...Speeds icon is used to increase or de crease the blower speed once the blower is On Press and hold the icon to decrease the blower speed until the desired intensity is reached then release Press and...

Page 14: ...and holding the key for more than 5 seconds during the purge idle period LED Light Icon Hold the key for less than two 2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds...

Page 15: ...be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment HUMIDITY Warning Avoid high humidity levels in your home Mold mildew fungi and b...

Page 16: ...to cool down Check service wire size c Refer to Jason Customer Service d Fill to recommended level Pump does not turn off after set time elapses a Wiring error or control problem a Refer to installer...

Page 17: ...circulatory system problems or diabetes should consult a physician before using a therapy bath G Personsusingmedicationshouldconsultaphysicianbeforeusingatherapybathsincesomemedicationmayinducedrowsin...

Page 18: ...rnational Inc 501 771 4477 Page 18 of 18 Customer Service 800 255 5766 Copyright 2011 Jason International Jason International Inc 8328 MacArthur Drive North Little Rock Arkansas 72118 www jasoninterna...

Reviews: