Jason International, Inc. •
501.771.4477
Page 12 of 18
Customer Service : 800.255.5766
Copyright © 2011 Jason International.
Never operate the system without the pre-filter, internal
filter screen and suction cover installed.
blower
The blower generates warm air and pushes it through the air
jets. Blowers provided on Jason AirMasseur baths are factory
tested when assembled and again retested after installation
on the bath.
standard Edition Automatic purge
Fifteen (15) minutes after the control has shut off and the
bath is completely drained, the blower will start again for a
two0minute purge cycle that dries the air channel. Note that
the blower light will flash during the 15-minute pause before
the purge cycle begins. Once the purge cycle begins, all
indicators will light and the keypad operation will be disabled
for two (2) minutes.
signature Edition Automatic purge
Twenty (20) minutes after the control has shut off and the
bath is completely drained, the blower will start again for a
two minute purge cycle that dries the air channel. Note that
the LCD display will read “PURGE” and begin to countdown
the 10 or 20 minute pause before the purge cycle begins. The
readout will display “PURGE ON” during the purge cycle. Any
time during the pause before the purge cycle begins, pressing
and holding the Blower Speeds icon will reduce the pause
from 20 minutes to 10 minutes. During the two-minute purge,
pressing the “Blower On/Off” icon will stop the purge.
signature Edition Daily purge
The daily purge can be activated through the customized
settings of the Signature Edition touchpad. When activated,
the daily purge will start the blower for two-minutes at
the same time every day to dry the air channel. See
“Operating the Signature Edition MicroSilk AirMasseur
Touchpad” section for details on activating this setting.
Filling And Draining
Close the drain and fill the bath with water at least two
(2) inches (50mm) above the jets. The inlet temperature
should not exceed 40
o
C (104
o
F) as this could damage
the acrylic surface. When bath is in use, turn the unit Off
before draining the water. The bath unit and its plumbing
are designed to drain after each use whether used as a
hydrotherapy bath, soaking bath, or just taking a shower.
OpERAting instRuctiOns, FEAtuREs, AnD cOntROLs (cont.)
NOTe: If the unit fails to operate, check the breaker panel
to insure that the circuit breaker is on. Check the GFCI by
testing and resetting it. Also check the water level in the
bath; it must be above the water level sensor located on
the sidewall of the bath for the pump to operate. If the unit
still fails to operate, refer to the Trouble Shooting Guide
section on page 15 of this manual. If the unit still fails
to operate and is out of warranty, contact an authorized
service technician for repair. If the unit is within the
warranty period, contact JASON Technical Services at
800-255-5766. DO NOT ATTeMpT TO ReSOlve The
pRObleM.