background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 17 of 18

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2011 Jason International.

IMPORTANT SAFETY INSTRUCTIONS

InsTruCTIOns PerTaInIng TO The rIsK Of fIre, eleCTrIC shOCK, Or InJurY TO Per-

sOns.

This manual contains information and instructions for proper operation and maintenance of your therapy bath.  Failure to follow these 
instructions could result in personal injury, electrical shock, or fire.

warnIng: when using this unit, basic precautions should always be followed, including the following:

reaD anD fOllOw all InsTruCTIOns CarefullY

Danger:

 

TO reDuCe The rIsK Of InJurY fOllOw These PreCauTIOns: 

a.

  Do not permit children to use this product unless they are closely supervised at all times.

B.

  Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufac-

turer.

C.

  The water in a  therapy bath should never exceed 40°C (104°F). Water temperatures between 38°C (100°F) and 40°C (104°F) are 

considered safe for a healthy adult. Use time should be limited to approximately 30 minutes, followed by a shower to cool down. 
Longer exposures may result in hyperthermia. The symptoms of this condition are nausea, dizziness and fainting, and it can be 
fatal. Lower water temperatures are recommended for extended use (exceeding 10 -15 minutes) and for young children.

D.

  Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, 

pregnant or possibly pregnant women should limit therapy bath water temperatures to 38°C (100°F).

e.

  The  use  of  drugs  or  alcoholic  beverages  before  or  during  therapy  bath  use  may  lead  to  unconsciousness  with  the 

possibility  of  drowning.  Never  use  the  therapy  bath  while  under  the  influence  of  alcohol,  anticoagulants,  stimulants,  
antihistamines, vasoconstrictors, vasodilators, hypnotics, narcotics, or tranquilizers.

f.

  Persons with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should 

consult a physician before using a therapy bath.

g.

  Persons using medication should consult a physician before using a therapy bath since some medication may induce drowsiness 

while other medication may affect heart rate, blood pressure, and circulation.

Danger:

 

 

To reduce the risk of injury, enter and exit the bath slowly. 

Do not operate this unit unless the suction cover is attached over 

the suction inlet fitting and the jet assemblies are installed.  There should be at least two (2) inches of water above the highest jet 
location during therapy bath operation.

 neVer run unIT DrY.

warnIng:

 

Never operate electrically connected devices in or near the bath. Never drop or insert any object into any opening.

This unit must be connected to a supply circuit that is protected by a GFCI. Such a device should be installed by a licensed electrician 
and should be tested on a regular basis (at least monthly). To test the GFCI push the 

TesT

 button. The GFCI should interrupt the 

power. Push the 

reseT

 button and the power should be restored. If the GFCI fails to operate in this manner, there is the possibility 

of an electric shock. 

DO nOT use. 

Disconnect the unit and have the problem corrected by a qualified service technician. 

To avoid the possibility of personal injury and discoloration of the acrylic surface, the inlet water temperature should not exceed 
40°C (104°F). The bath should be drained after each use. Each bather should start their bath with fresh water. Do not use oil base 
additives in your therapy bath.

CauTIOn: 

Do not use harsh abrasives or solvents for cleaning this unit.

InsTaller/Owner Bears all resPOnsIBIlITY TO COMPlY wITh all sTaTe  

anD lOCal CODes when InsTallIng ThIs PrODuCT.

saVe These InsTruCTIOns

Jason International, Inc. (Jason), warrants its baths to be free from defects in workmanship and materials as provided in the enclosed warranty 

statement and warranty validation card.
The pre-addressed warranty registration card MusT be filled out by the purchaser within thirty (30) days from purchase and mailed to Jason Inter-

national, Inc., in order for limited warranty to become effective.

warranTY

Summary of Contents for BY630

Page 1: ...s responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered If the carton shows sign of damage inspect the product before accepting and describe the prob...

Page 2: ...cm 236 66 x 36 x 20 5 39 36 x 17 in 47 4 168 x 91 x 52 148 91 x 43 cm 231 72 x 36 x 20 5 45 36 x 17 in 47 6 183 x 91 x 52 170 91 x 43 cm 232 60 x 42 x 20 5 49 36 x 17 in 43 5 152 x 107 x 52 185 91 x 4...

Page 3: ...oor or the skirt will not fit properly 100 Silicone with mildew resistant properties should 2 be applied between the water resistant backer board and the deck of the bath NOTE If you use a tile flange...

Page 4: ...hanges A 90 direction change should be made up of two 45 elbows for maximum efficiency If the blower has been factory installed disconnect the 2 blower from the air bath plumbing by removing the two 2...

Page 5: ...lconnectionsonthedischargeside are tight See Figure 7 Assure the MicroSilk Jet Flex Hose will allow proper drainage to the jets All hoses must haveacontinuousdropfromthesaturationtanktothejets Note Ve...

Page 6: ...er is prewired to the control box The control boxes have a 36 91cm cord with plug end The MicroSilk and blower control boxes are mounted on a stand that is temporarily secured to the packing board for...

Page 7: ...ctoryinstalledwiring Allbuilding materialsandwiringshouldberoutedawayfromtheequipment or other heat producing components of the unit Figure 9 Figure 9A NOTE The load neutral terminal is not used There...

Page 8: ...acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing test...

Page 9: ...RMASSEUR Jason s Premier Edition MicroSilk AirMasseur system incor porates all the features of the Standard Edition system and includesthebenefitsofanozonesanitationsystem andanLED Chromatherapylight...

Page 10: ...ensor must be plugged into the proper receptacle for correct operation of the MicroSilk AirMasseur system See Figure 12 for connections A The junction box for the MicroSilk blower control boxes must b...

Page 11: ...r blower with heater and three 3 massage modes Continuous Wave or Pulse The system also includes a Chromatherapy mood light Automatic Ozone System that will be operated any time the blower is powered...

Page 12: ...es to 10 minutes During the two minute purge pressing the Blower On Off icon will stop the purge Signature Edition Daily Purge The daily purge can be activated through the customized settings of the S...

Page 13: ...Speeds icon is used to increase or de crease the blower speed once the blower is On Press and hold the icon to decrease the blower speed until the desired intensity is reached then release Press and...

Page 14: ...and holding the key for more than 5 seconds during the purge idle period LED Light Icon Hold the key for less than two 2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds...

Page 15: ...be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment HUMIDITY Warning Avoid high humidity levels in your home Mold mildew fungi and b...

Page 16: ...to cool down Check service wire size c Refer to Jason Customer Service d Fill to recommended level Pump does not turn off after set time elapses a Wiring error or control problem a Refer to installer...

Page 17: ...circulatory system problems or diabetes should consult a physician before using a therapy bath G Personsusingmedicationshouldconsultaphysicianbeforeusingatherapybathsincesomemedicationmayinducedrowsin...

Page 18: ...rnational Inc 501 771 4477 Page 18 of 18 Customer Service 800 255 5766 Copyright 2011 Jason International Jason International Inc 8328 MacArthur Drive North Little Rock Arkansas 72118 www jasoninterna...

Reviews: