background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 15 of 20

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2018 Jason International, Inc.

INSTALLATION INSTRUCTIONS (cont.)

The Jason AirMasseur® system has been factory installed 

following ETL/UL Standard safety guidelines.  During in-

stallation, if remote mounting of the air blower is desired or 

required, the following procedures should be followed.

Note:

 Do not remote mount the blower more than 15 feet 

[4.5m] away from the air inlet of the bath.  Choose a loca-

tion as close as possible to the bath to ensure maximum 

efficiency.

1.  The installer must determine the layout of the piping; 

exact remote mount location; and service access be-

fore beginning any work.  Use 1.5” ABS or PVC plastic 

tubing.  Locate the control box with the blower in an 

area accessible for servicing.

Note:

 A 15 foot extension cable set can be purchased 

from your Jason supplier, if needed.  To ensure proper 

functioning of the system, avoid remote mounting in a 

location which requires more than six (6) piping direc-

tion changes.  A 90° direction change should be made 

up of two 45° elbows for maximum efficiency.

2.  Install the blower and control box in the remote loca-

tion.  The remote mount location ambient air tempera-

ture should remain at approximately 72°F [22°C] for 

optimum air heating.

3.  A minimum ventilation opening of 2” x 4” [5x10cm] 

for the AirMasseur blower is required.  It should be 

designed to draw in indoor ambient air at a minimum 

of 72°F [22°C]. 

4.  The blower mount should be attached firmly to the 

floor.  

5.  Use screws to attach the pipe to the check valve and 

route the hose to the remote blower tubing floor cutout 

location.  CAUTION: Do NOT use ABS or PVC glue 

near the blower, it could ignite and cause a fire.

6.  Extend piping stub-out through the floor as illustrated 

in Figure 8. Piping between the remote blower loca-

tion and the bath can be insulated using a minimum of 

½” [13mm] thick insulation.  Attach new piping to the 

elbow of the existing piping. 

7.  Attach one end of the blower hose to the bath connec-

tion with the included clamp.

WARNING: Any modification to the equipment is 

not recommended and will void the Manufacturer’s 

warranty.

8.  Attach the other end of the hose to the PVC pipe that 

is plumbed to the blower with the included clamp.

9.  Route the electronic cables through the floor cutout to 

be connected to the control box.  

WARNING: When routing cables, do not allow the 

cable to be pinched under the bath shell.

NOTE:

 A minimum of 4 feet [122cm] of hose and 

cable must be free from binding to allow for pulling the 

cables back up through the floor cutout.

10.  During installation if it is preferred to run the blower 

hose on top of the floor, a 2-1/2” [6.35cm] diameter 

holes can be drilled at the bottom of the skirt.  A 

means to cover the hole, hose and wires is not pro-

vided. See 

Figure 8a

11.  Return to the bath installation section to finish installa-

tion of the freestanding bath.

REMOTE MOUNTING OF AIR BLOWER

Summary of Contents for Designer AN-P Series

Page 1: ...o respond should be reported to the seller and carrier Always file a freight claim promptly The installer is responsible for insuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been avoided by inspection or testing prior to installation Damage to the unit during installati...

Page 2: ...ol anticoagulants stimulants antihistamines vasoconstric tors vasodilators hypnotics narcotics or tranquilizers F Lower water temperatures are recommended for extended use exceeding 10 15 minutes and for young children G Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit therapy bat...

Page 3: ...e 10 15 minutes et pour les jeunes enfants F Puisque les températures excessives ont un potentiel élevé pour les fœtus durant les premiers mois de la grossesse les femmes enceintes ou possiblement enceintes doivent limiter la température de l eau de bain de traitement à 38 C G Personnes ayant des antécédents de maladie cardiaque d hypotension ou d hypertension artérielle de troubles circulatoires ...

Page 4: ...rantie du fabricant DANGER Ne pas modifier le câblage installé en usine Tous les matériaux de construction et câblage doivent être éloignés de toutes sources de chaleur moduites par le abin ATTENTION Garder les cheveux les serviettes et les vête ments à distance du raccord d aspiration lorsque l appareil est allumé Ne jamais faire fonctionner l équipement avec l aspiration couvrir off cela annule ...

Page 5: ...er to the Trouble Shooting Guide section of this manual If the unit still fails to operate and is out of warranty contact an authorized service technician for repair If the unit is within the warranty period contact JASON Technical Services at 800 255 5766 DO NOT ATTEMPT TO RESOLVE THE PROBLEM FEATURES Jason offers the finest in soaking hydrotherapy baths but also offers the option for more hydrot...

Page 6: ...er to the OPERATING INSTRUC TIONS section for further details regarding the Automatic Purge Standard Edition AirMasseur The Jason Standard Edition AirMasseur hydrotherapy in cludes a variable speed 1 HP air blower with heater three 3 massage modes Continuous Wave or Pulse automat ic purge cycle an electronic control and a 20 minute timer Premier Edition AirMasseur The Jason Premier Edition AirMass...

Page 7: ...or color Press and hold the icon to cycle through the FADE mode release the icon to choose any custom color Order of Colors Slow Fade Mode Color Step changes each second Purple Green Red Blue Yellow White then Off The MICROSILK icon is used to activate the MicroSilk unit and the 20 minute timer Once pressed the microbubble generator will start and the icon will turn BLUE Pressing the icon again wi...

Page 8: ...cate the icons A menu will be displayed to choose the following Purge 24 starts the blower every 24 hours for two 2 minutes at the time the purge was set Product Test Diagnostics Temperature F or C and Language English or Spanish Menu Instructions Use the top AIRMASSEUR icon to scroll through the different menu items Use the Blower SPEED icon to change an option For example press and release the A...

Page 9: ...irst press and CONST AIR will be displayed WAVE Mode will start with the next press and WAVE AIR will be displayed PULSE Mode will start with the next press and PULSE AIR will be displayed Pressing the icon again will shut the blower OFF Starting the AirMasseur will turn OFF any other therapy equipment running at that time Once the system returns to Standby mode the purge timer will be displayed A...

Page 10: ...ps Rinse the bath thoroughly after cleaning SURFACE MAINTENANCE Area with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e No vus Plastic Polish No 2 available at your Jason dealer followed by an application of acrylic paste wax Buff the surface with a clean soft cloth Do not use sandpaper steel wool or abrasive rubbing compounds If scratches a...

Page 11: ... wall mounted faucet be sure to in stall the faucet to allow for sufficient overhang into the well of the bath This will ensure an unobstructed water flow out of the faucet when filling the bath Fol low the faucet manufacturer s installation instructions Note Overflow drains fill spouts and valves must be installed according to the instructions herein 5 Installation template An installation templa...

Page 12: ...Figure 3 CAUTION Use a marker that can be removed from the finished floor after installation 12 Remove the template for the floor 13 Install the locating studs into the four 4 positions on the floor See Figure 3 14 Drain and Overflow Use the 1 1 2 coupling which is pre attached to the bath and lengthen the overflow pipe to the desired length Then attach the drain to the bath 15 Remote Mounting of ...

Page 13: ... be tested with out filling the bath with water to assure that all electric connections are properly working Note Refer to the Electrical section for correct installation of electrical components Note Refer to the Product Test Diagnostics in the Operating Features and Controls section for test ing 23 It is recommended that the bath be water tested filled and operated and the bath be inspected for ...

Page 14: ...a switch in conjunction with a control device This will VOID THE MANUFACTURER S WARRANTY ELECTRICAL INSTALLATION The pumps are supplied with an electrical bonding lug to allow connection of a solid copper bonding conductor be tween the unit and other electrical equipment and exposed metal in the area as may be required by local code Note The air blower s exterior housing is made of all plastic ma ...

Page 15: ...s required It should be designed to draw in indoor ambient air at a minimum of 72 F 22 C 4 The blower mount should be attached firmly to the floor 5 Use screws to attach the pipe to the check valve and route the hose to the remote blower tubing floor cutout location CAUTION Do NOT use ABS or PVC glue near the blower it could ignite and cause a fire 6 Extend piping stub out through the floor as ill...

Page 16: ...loca tion of the 2 decorative screw caps installed on the cabinet See Figure 9 4 Measure 1 5 3 8cm from the marked location of the decorative screws and use the 2 included 12 screws to attach the brackets to the floor at these loca tions See Figure 10a 5 Place the equipment between the brackets and attach all the plumbing and electrical connections Note The electrical service can be provided insid...

Page 17: ...ump 1 2 J SON t dĞŵƉ ĞŶƐŽƌ dtͲϮϬϵ ĞLJƉĂĚ hͲϮϲϰͲϬϭͲϬϰ KnjŽŶĞ D ͲϮϭϯ dŽ ĞĚŝĐĂƚĞĚ ϭϮϬs ϲϬ nj ϮϬ WƌŽƚĞĐƚĞĚ ĞƌǀŝĐĞ DĂůĞ EĞŵĂ ŝŶĞ ŽŶŶĞĐƚŝŽŶ DĂůĞ EĞŵĂ ŝŶĞ ŽŶŶĞĐƚŝŽŶ Ɛ ͲϮϵϳ ĂďůĞ Ͳϯϲϲ ĂďůĞ Ͳϯϲϲ D WƵŵƉ ĂĚĂƉƚĞƌ ͲϯϬϭ ĞLJƉĂĚ ĂďůĞ Ͳϭϲϴ TRANSDUCER BLACK RED BLACK RED BLUETOOTH AMPLIFIER Optional Bluetooth Sound Immersion Transducers installed on bath Bluetooth amp supplied and field installed 120V 60Hz 15A To Dedica...

Page 18: ...ble CBL 372 Mrce 1 Ncmi Pinc Mloi Drooidvlro Cmrzis 1 2 Keypad IDU 264 J SON Ozone D ͲϮϭϯ dŽ ĞĚŝĐĂƚĞĚ ϭϮϬs ϲϬ nj ϮϬ WƌŽƚĞĐƚĞĚ ĞƌǀŝĐĞ DĂůĞ EĞŵĂ ŝŶĞ ŽŶŶĞĐƚŝŽŶ ĞLJƉĂĚ hͲϮϲϰͲϬϭͲϬϭ Ɛ ͲϮϵϳ ĂďůĞ Ͳϯϲϲ ĂďůĞ Ͳϯϲϲ t dĞŵƉ ĞŶƐŽƌ dtͲϮϬϵ DĂůĞ EĞŵĂ ŝŶĞ ŽŶŶĞĐƚŝŽŶ ůŽǁĞƌ ĂĚĂƉƚĞƌ ͲϯϬϭ KnjŽŶĞ ĞLJƉĂĚ ĂďůĞ Ͳϭϲϴ TRANSDUCER BLACK RED BLACK RED BLUETOOTH AMPLIFIER Optional Bluetooth Sound Immersion Transducers installed on bat...

Page 19: ...y inserted into the control box outlet c Check and reconnect if necessary Equipment does not manually shut off a Control defective a Refer to installer dealer Equipment shuts off by itself or before set time elapses a Motor overheated and thermal protection device deactivated motor Possible low voltage b GFCI tripped c Water level fell below recommended level Signature a Make sure motor has suffic...

Page 20: ...air channel dry and sanitary TROUBLE SHOOTING GUIDE WARRANTY REGISTRATION Register your product s warranty online at www jasoninternational com JASON INTERNATIONAL INC LIMITED WARRANTY Jason International Inc Jason warrants its baths to be free from defects in workmanship and materials as provided in the enclosed Warranty Statement and Warranty validation card The pre addressed warranty registrati...

Reviews: