background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 4 of 20

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2018 Jason International, Inc.

Cautionary Warnings (English/French)

CAUTION: Ambient temperature under the bath where equip-
ment is installed must not exceed 122°F (50°C).

WARNING: Any modification to the equipment is not recom-
mended and will void the Manufacturer’s warranty.

DANGER - RISK OF ELECTRIC SHOCK: 

Connect only to a cir-

cuit protected by a Ground Fault Circuit Interrupter (GFCI). In the 
unlikely occurrence of a current imbalance in the power conduc-
tors, the GFCI will interrupt the power to the bath.

WARNING: The electrical service to the GFCI must not be 
interrupted by any control device. Likewise, the electrical 
service from the GFCI to the bath control should be direct 
and not interrupted by a switch. Never use a switch in con-
junction with a control device.
This will VOID THE MANUFACTURER’S WARRANTY.

DANGER - Do not alter the factory installed wiring. All build-
ing materials and wiring should be routed away from the 
equipment or other heat-producing components of the unit.

CAUTION: 

Keep hair, towels, and clothing away from the suction 

fitting whenever the equipment is On. Never operate the equip-
ment with the suction cover off, doing so voids the manufacturer’s 
warranty--it is a safety cover designed to eliminate the potential 
of hair and body entrapment.

ATTENTION: la temperature ambiante sous la baignoire où 
l’équipement est installé ne doit pas dépasser 50°C.

AVERTISSEMENT : Toute modification de l’équipement n’est 
pas recommandé et annulera la garantie du fabricant.

DANGER - RISQUE DE CHOC ÉLECTRIQUE : 

Connecter 

uniquement à un circuit protégé par un disjoncteur (GFCI). Dans 
l’éventualité peu probable d’un déséquilibre de courant, le GFCI 
coupera le courant du bain.

AVERTISSEMENT : Le service électrique au GFCI ne doit 
pas être interrompu par un dispositif de contrôle. De même, 
le service électrique du GFCI au contrôle de bain doit être 
direct et ininterrompu par un controlleur. Ne jamais utiliser 
un commutateur en conjonction avec un dispositif de com-
mande.
Cela annulera la garantie du fabricant.

DANGER - Ne pas modifier le câblage installé en usine. 
Tous les matériaux de construction et câblage doivent être 
éloignés de toutes sources de chaleur moduites par le abin.

ATTENTION : 

Garder les cheveux, les serviettes et les vête-

ments à distance du raccord d’aspiration lorsque l’appareil est 
allumé. Ne jamais faire fonctionner l’équipement avec l’aspiration 
couvrir off, cela annule la garantie - c’est un dispositif de sécurité 
conçu à éviter l’occulusion du corps et des cheveux.

AVERTISSEMENT: Avant d’opérer le bain consulter les 
instructions à la fin de ce manuel concernant les risques 
d’incendie, de choc électrique ou de blessure ce proprié-
taire.

AVERTISSEMENT: Évitez les hauts niveaux d’humidité dans 
votre maison. Les Moisissures, champignons et certaines 
bactéries peuvent être nocifs pour la santé et se dévelop-
per dans ces zones; par conséquent, toutes les précautions 
doivent être prises pour vous assurer que votre plomberie, y 
compris les baignoires, bains thérapeutiques, ou les douch-
es ne deviennent pas une source de forte humidité due à 
une mauvaise installation ou de fuites.

AVERTISSEMENT: Toujours couper l’alimentation électrique 
au panneau de service électrique avant la maintenance.

ATTENTION :

 Risque de choc électrique - Deux interrupteurs de 

déconnexion sont nécessaires pour mettre l’unité hors tension 
avant l’entretien. [Pour les bains nécessitant deux circuits]

ATTENTION: Ne convient pas aux appareils de chauffage 
installés sur le terrain

WARNING: Before operating refer to the instructions at the 
end of this owner’s manual pertaining to the risk of fire, elec-
tric shock, or injury to persons.

WARNING: Avoid high humidity levels in your home. Mold, 
mildew, fungi and bacteria which may be harmful to health 
thrive in areas with continued high humidity levels; there-
fore, every precaution should be taken to make sure your 
plumbing fixtures including bathtubs, therapy baths, or 
showers do not become a source of high humidity due to 
improper installations or leaks.

WARNING: Always turn off power at the main electrical ser-
vice panel when servicing the bath

CAUTION: Risk of Electric Shock - -

Two disconnect switches 

are required to de-energize the unit before servicing.  [For baths 
requiring two circuits]

CAUTION: Not Suitable for Field-Installed Heater

Summary of Contents for Designer AN-P Series

Page 1: ...o respond should be reported to the seller and carrier Always file a freight claim promptly The installer is responsible for insuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been avoided by inspection or testing prior to installation Damage to the unit during installati...

Page 2: ...ol anticoagulants stimulants antihistamines vasoconstric tors vasodilators hypnotics narcotics or tranquilizers F Lower water temperatures are recommended for extended use exceeding 10 15 minutes and for young children G Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit therapy bat...

Page 3: ...e 10 15 minutes et pour les jeunes enfants F Puisque les températures excessives ont un potentiel élevé pour les fœtus durant les premiers mois de la grossesse les femmes enceintes ou possiblement enceintes doivent limiter la température de l eau de bain de traitement à 38 C G Personnes ayant des antécédents de maladie cardiaque d hypotension ou d hypertension artérielle de troubles circulatoires ...

Page 4: ...rantie du fabricant DANGER Ne pas modifier le câblage installé en usine Tous les matériaux de construction et câblage doivent être éloignés de toutes sources de chaleur moduites par le abin ATTENTION Garder les cheveux les serviettes et les vête ments à distance du raccord d aspiration lorsque l appareil est allumé Ne jamais faire fonctionner l équipement avec l aspiration couvrir off cela annule ...

Page 5: ...er to the Trouble Shooting Guide section of this manual If the unit still fails to operate and is out of warranty contact an authorized service technician for repair If the unit is within the warranty period contact JASON Technical Services at 800 255 5766 DO NOT ATTEMPT TO RESOLVE THE PROBLEM FEATURES Jason offers the finest in soaking hydrotherapy baths but also offers the option for more hydrot...

Page 6: ...er to the OPERATING INSTRUC TIONS section for further details regarding the Automatic Purge Standard Edition AirMasseur The Jason Standard Edition AirMasseur hydrotherapy in cludes a variable speed 1 HP air blower with heater three 3 massage modes Continuous Wave or Pulse automat ic purge cycle an electronic control and a 20 minute timer Premier Edition AirMasseur The Jason Premier Edition AirMass...

Page 7: ...or color Press and hold the icon to cycle through the FADE mode release the icon to choose any custom color Order of Colors Slow Fade Mode Color Step changes each second Purple Green Red Blue Yellow White then Off The MICROSILK icon is used to activate the MicroSilk unit and the 20 minute timer Once pressed the microbubble generator will start and the icon will turn BLUE Pressing the icon again wi...

Page 8: ...cate the icons A menu will be displayed to choose the following Purge 24 starts the blower every 24 hours for two 2 minutes at the time the purge was set Product Test Diagnostics Temperature F or C and Language English or Spanish Menu Instructions Use the top AIRMASSEUR icon to scroll through the different menu items Use the Blower SPEED icon to change an option For example press and release the A...

Page 9: ...irst press and CONST AIR will be displayed WAVE Mode will start with the next press and WAVE AIR will be displayed PULSE Mode will start with the next press and PULSE AIR will be displayed Pressing the icon again will shut the blower OFF Starting the AirMasseur will turn OFF any other therapy equipment running at that time Once the system returns to Standby mode the purge timer will be displayed A...

Page 10: ...ps Rinse the bath thoroughly after cleaning SURFACE MAINTENANCE Area with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e No vus Plastic Polish No 2 available at your Jason dealer followed by an application of acrylic paste wax Buff the surface with a clean soft cloth Do not use sandpaper steel wool or abrasive rubbing compounds If scratches a...

Page 11: ... wall mounted faucet be sure to in stall the faucet to allow for sufficient overhang into the well of the bath This will ensure an unobstructed water flow out of the faucet when filling the bath Fol low the faucet manufacturer s installation instructions Note Overflow drains fill spouts and valves must be installed according to the instructions herein 5 Installation template An installation templa...

Page 12: ...Figure 3 CAUTION Use a marker that can be removed from the finished floor after installation 12 Remove the template for the floor 13 Install the locating studs into the four 4 positions on the floor See Figure 3 14 Drain and Overflow Use the 1 1 2 coupling which is pre attached to the bath and lengthen the overflow pipe to the desired length Then attach the drain to the bath 15 Remote Mounting of ...

Page 13: ... be tested with out filling the bath with water to assure that all electric connections are properly working Note Refer to the Electrical section for correct installation of electrical components Note Refer to the Product Test Diagnostics in the Operating Features and Controls section for test ing 23 It is recommended that the bath be water tested filled and operated and the bath be inspected for ...

Page 14: ...a switch in conjunction with a control device This will VOID THE MANUFACTURER S WARRANTY ELECTRICAL INSTALLATION The pumps are supplied with an electrical bonding lug to allow connection of a solid copper bonding conductor be tween the unit and other electrical equipment and exposed metal in the area as may be required by local code Note The air blower s exterior housing is made of all plastic ma ...

Page 15: ...s required It should be designed to draw in indoor ambient air at a minimum of 72 F 22 C 4 The blower mount should be attached firmly to the floor 5 Use screws to attach the pipe to the check valve and route the hose to the remote blower tubing floor cutout location CAUTION Do NOT use ABS or PVC glue near the blower it could ignite and cause a fire 6 Extend piping stub out through the floor as ill...

Page 16: ...loca tion of the 2 decorative screw caps installed on the cabinet See Figure 9 4 Measure 1 5 3 8cm from the marked location of the decorative screws and use the 2 included 12 screws to attach the brackets to the floor at these loca tions See Figure 10a 5 Place the equipment between the brackets and attach all the plumbing and electrical connections Note The electrical service can be provided insid...

Page 17: ...ump 1 2 J SON t dĞŵƉ ĞŶƐŽƌ dtͲϮϬϵ ĞLJƉĂĚ hͲϮϲϰͲϬϭͲϬϰ KnjŽŶĞ D ͲϮϭϯ dŽ ĞĚŝĐĂƚĞĚ ϭϮϬs ϲϬ nj ϮϬ WƌŽƚĞĐƚĞĚ ĞƌǀŝĐĞ DĂůĞ EĞŵĂ ŝŶĞ ŽŶŶĞĐƚŝŽŶ DĂůĞ EĞŵĂ ŝŶĞ ŽŶŶĞĐƚŝŽŶ Ɛ ͲϮϵϳ ĂďůĞ Ͳϯϲϲ ĂďůĞ Ͳϯϲϲ D WƵŵƉ ĂĚĂƉƚĞƌ ͲϯϬϭ ĞLJƉĂĚ ĂďůĞ Ͳϭϲϴ TRANSDUCER BLACK RED BLACK RED BLUETOOTH AMPLIFIER Optional Bluetooth Sound Immersion Transducers installed on bath Bluetooth amp supplied and field installed 120V 60Hz 15A To Dedica...

Page 18: ...ble CBL 372 Mrce 1 Ncmi Pinc Mloi Drooidvlro Cmrzis 1 2 Keypad IDU 264 J SON Ozone D ͲϮϭϯ dŽ ĞĚŝĐĂƚĞĚ ϭϮϬs ϲϬ nj ϮϬ WƌŽƚĞĐƚĞĚ ĞƌǀŝĐĞ DĂůĞ EĞŵĂ ŝŶĞ ŽŶŶĞĐƚŝŽŶ ĞLJƉĂĚ hͲϮϲϰͲϬϭͲϬϭ Ɛ ͲϮϵϳ ĂďůĞ Ͳϯϲϲ ĂďůĞ Ͳϯϲϲ t dĞŵƉ ĞŶƐŽƌ dtͲϮϬϵ DĂůĞ EĞŵĂ ŝŶĞ ŽŶŶĞĐƚŝŽŶ ůŽǁĞƌ ĂĚĂƉƚĞƌ ͲϯϬϭ KnjŽŶĞ ĞLJƉĂĚ ĂďůĞ Ͳϭϲϴ TRANSDUCER BLACK RED BLACK RED BLUETOOTH AMPLIFIER Optional Bluetooth Sound Immersion Transducers installed on bat...

Page 19: ...y inserted into the control box outlet c Check and reconnect if necessary Equipment does not manually shut off a Control defective a Refer to installer dealer Equipment shuts off by itself or before set time elapses a Motor overheated and thermal protection device deactivated motor Possible low voltage b GFCI tripped c Water level fell below recommended level Signature a Make sure motor has suffic...

Page 20: ...air channel dry and sanitary TROUBLE SHOOTING GUIDE WARRANTY REGISTRATION Register your product s warranty online at www jasoninternational com JASON INTERNATIONAL INC LIMITED WARRANTY Jason International Inc Jason warrants its baths to be free from defects in workmanship and materials as provided in the enclosed Warranty Statement and Warranty validation card The pre addressed warranty registrati...