AIR FEATURES
AirMasseur
®
Blower
The blower generates warm air and pushes it through
the strategically placed air jets. The AirMasseur
system contains a variable speed-controlled heated
air blower. Blowers provided on Jason baths are
factory tested when assembled on the bath.
Air ON/OFF Button
The Air On/Off button (air
switch activator) allows
the user to turn the blower
On and Off and controls
the blower’s intensity.
Momentarily depress the
button to start or stop the
air blower. A timer will automatically stop the air
blower after 20 minutes of operation if it is not
stopped manually.
Blower Speed
Once the blower is On, to decrease the air output,
press and hold the Air On/Off button until the desired
intensity is reached, then release the button. To
increase the air intensity, press and hold the Air
On/Off button until the desired intensity is reached,
then release the button.
AirMasseur
®
Automatic Purge
Fifteen (15) minutes after the blower is stopped, the
blower will start again for a two (2) minute purge cycle
that dries the air channel.
REMOTE MOUNTING OF AIR BLOWER
The Jason AirMasseur
®
system has been factory
installed following ETL/UL Standard safety guidelines.
During installation, if remote mounting of the air blower
is desired or required, the following procedures should
be followed.
Note:
Do no remote mount the blower more than 15
feet [4.5m] away from the air inlet of the bath. Choose
a location as close as possible to the bath to ensure
maximum efficiency.
1. The installer must determine the layout of the
piping; exact remote mount location; and
service access before beginning any work. Use
1.5” ABS or PVC plastic tubing. Locate the
blower in an area accessible for servicing.
1.
Note:
A 15 foot extension cable set can be
purchased from your Jason supplier, if needed.
To ensure proper functioning of the system,
avoid remote mounting in a location which
requires more than six (6) piping direction
changes. A 90° direction change should be
made up of two 45° elbows for maximum
efficiency.
2. If the blower has been factory installed,
disconnect the blower from the air bath
plumbing by removing the two (2) screws on the
check valve outlet and disconnect the short
piece of pipe between the check valve and the
elbow by removing the two (2) screws in the
elbow. [Omit this step on baths where the
blower is not factory installed and remote
mounting is required.]
3. Install the blower in the remote location. The
remote mount location ambient air temperature
should remain at approximately 72°F [22°C] for
optimum air heating.
4. Make sure the blower is well ventilated. The
blower mount should be attached firmly to the
floor. Piping between the remote blower
location and the bath can be insulated using a
minimum of ½” [13mm] thick insulation. Attach
new piping to the elbow of the existing piping.