5.  Integral Tile Lip Alcove Installation 

After the bath has been leveled, confirm the height 
measurement of the underside of the flange deck in 
order to install a 1”x2” ledger strip to support the tile lip 
flange (see 

Figure 4

).

 

 

Figure 4 

 
Install the 1” x 2” support ledger strip to the framing to 
allow support along the entire rear ledge of the bath 
(see 

Figures 2 and 5

).

 

 
6. Tile Flange 

100% Silicone with mildew resistant properties should 
be applied between the water resistant backer board 
and the deck of the deck. 
 

Note:

 If you use a tile flange kit, modify the framing to 

support the bath lip as shown in 

Figure 5

 

Figure 5 

 
7. Acrylic Bath Surface

 

The acrylic surface of this bath has been provided with 
a protective film which helps protect the bath during 
shipment and installation.  If the bath is tiled in, remove 
the necessary portion of the film when installing the tile. 

 

Additional protection may also be required to protect 
the acrylic surface during installation. Protect the acrylic 
bath surface from damage during installation with a 
suitable material, i.e. cardboard and/or plastic film.   
 

 

8. Cleaning

 

Remove all loose debris.  Construction plaster or excess 
grout can be removed with the use of a wood (edge) 
trowel.  Paint or tar stains may need to be removed with 
a cleaner such as paint thinner, turpentine or rubbing 
alcohol.  Never allow the cleaner to soak against the 
acrylic surface for long periods of time. 

Always rinse 

the surface immediately following the use of 
cleaners. 
 
9. Water Testing

 

Before finishing the installation, it is recommended that 
the bath be water tested and any plumbing tested for 
leaks. 
 
 
 

 

INSTALLATION INSTRUCTIONS (cont.)

 

Summary of Contents for Excel

Page 1: ...o installation Damage to the unit during installation will not be covered by warranty and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INSTALLATION Inspect plumbing and bath surface for missing or damaged components Alert your dealer of any discrepancies To protect the unit from damage keep the bath in the carton until ready for install...

Page 2: ...hol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Lower water temperatures are recommended for extended use exceeding 10 15 minutes and for young children G Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit therapy bat...

Page 3: ...10 15 minutes et pour les jeunes enfants F Puisque les températures excessives ont un potentiel élevé pour les fœtus durant les premiers mois de la grossesse les femmes enceintes ou possiblement enceintes doivent limiter la température de l eau de bain de traitement à 38 C G Personnes ayant des antécédents de maladie cardiaque d hypotension ou d hypertension artérielle de troubles circulatoires ou...

Page 4: ...aths requiring two circuits CAUTION Not Suitable for Field Installed Heater ATTENTION la temperature ambiante sous la baignoire où l équipement est installé ne doit pas dépasser 50 C AVERTISSEMENT Toute modification de l équipement n est pas recommandé et annulera la garantie du fabricant DANGER RISQUE DE CHOC ÉLECTRIQUE Connecter uniquement à un circuit protégé par un disjoncteur GFCI Dans l éven...

Page 5: ...ther used as a hydrotherapy bath soaking bath or just taking a shower NOTE If the unit fails to operate check the breaker panel to ensure that the circuit breaker is on Check the GFCI by testing and resetting it If the unit still fails to operate refer to the Trouble Shooting Guide section of this manual If the unit still fails to operate and is out of warranty contact an authorized service techni...

Page 6: ...ollowing procedures should be followed Note Do no remote mount the blower more than 15 feet 4 5m away from the air inlet of the bath Choose a location as close as possible to the bath to ensure maximum efficiency 1 The installer must determine the layout of the piping exact remote mount location and service access before beginning any work Use 1 5 ABS or PVC plastic tubing Locate the blower in an ...

Page 7: ...ughly after cleaning SURFACE MAINTENANCE Area with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jason dealer followed by an application of acrylic paste wax Buff the surface with a clean soft cloth Do not use sandpaper steel wool or abrasive rubbing compounds If scratches are too deep to rub out o...

Page 8: ...mum of 72 F 22 C 3 Drain and Overflow Install the drain and overflow assembly to the bath shell according to the instructions provided with the drain and position the bath in the area of intended installation Finish plumbing rough in of drain and overflow assembly At this time considerations should be made for the position and mounting of the faucet set as well as all related plumbing 4 Level Inst...

Page 9: ...ace of this bath has been provided with a protective film which helps protect the bath during shipment and installation If the bath is tiled in remove the necessary portion of the film when installing the tile Additional protection may also be required to protect the acrylic surface during installation Protect the acrylic bath surface from damage during installation with a suitable material i e ca...

Page 10: ... and not interrupted by a switch Never use a switch in conjunction with a control device This will VOID THE MANUFACTURER S WARRANTY The pumps are supplied with an electrical bonding lug to allow connection of a solid copper bonding conductor between the unit and other electrical equipment and exposed metal in the area as may be required by local code Note The air blower s exterior housing is made ...

Page 11: ... If no voltage control is defective b Motor is not plugged into control box b Make sure plug is fully inserted into the control box outlet c Air switch Plastic air tubing disconnected or broken c Check and reconnect if necessary Equipment does not manually shut off a Control defective a Refer to installer dealer Equipment shuts off by itself or before set time elapses a Motor overheated and therma...

Page 12: ...ent of equipment shall be F O B point of shipment This warranty shall not apply to any merchandise which has been subject to accident alteration abuse misuse abrasives corrosion and or electrolysis improper voltage supply misapplication careless handling improper installation maintenance abnormal chemical conditions nor does this warranty cover stains discoloration or the fading of color due to im...

Reviews: