Jason International, Inc. •
501.771.4477
Page 10 of 18
Customer Service : 800.255.5766
Copyright © 2011 Jason International.
SIgNATURe eDITION MICROSILK-WhIRLPOOL
PARTS LIST
MicroSilk Pump Unit
MicroSilk Control Box
Pump
Pump Control Box
Keypad
Keypad Cable
Control Box Stand
Water Level/Temp Sensor
LED Light Assembly
LED Light Cable
Vacuum Sensor
Ozone Sanitation Unit
Heater
Jason’s Signature Edition MicroSilk-Whirlpool system is the
most advanced bath manufactured by Jason International,
Inc. and features the ultimate in luxury bathing for the leisure
bath industry. The MicroSilk and pump control boxes must
be properly connected for the bath to function correctly.
INITALIZATION OF SIgNATURe eDITION CONTROL
SySTeM
The pump and MicroSilk junction box must be connected to
its dedicated service prior to filling the bath with water.
This
will assure the control box is properly initialized.
The MIRCROSILK CONTROL bOX
The MicroSilk unit must be plugged into the proper receptacle
for correct operation of the MicroSilk-Whirlpool system. See
Figure 12
for connections: (I) The MicroSilk pump’s power
cord will need to be plugged into the control box (H). Refer
to the
ELECTRICAL
section of this manual for connecting
the pump to the control box.
The PUMP CONTROL bOX
The Pump, Keypad, LED light, Ozone Sanitation Unit, Vac-
uum Switch, and Water Level/Temperature Sensor must be
plugged into the proper receptacles for correct operation of the
MicroSilk-Whirlpool system. See
Figure 12
for connections:
(A) The junction box for the pump/MicroSilk control boxes
and heater must be connected into a 240v, 20 amp GFCI
dedicated circuit. (B) Pre-wired power cords to pump (C) and
ozone unit (G). Eight-pin mini-DIN terminal for installation of
Air-Whirlpool keypad (F). Six-pin mini-DIN terminals for the
water/temperature sensor (D), and LED light (E) to the pump
control box. (J) Two-pin terminal for installation of the vacuum
switch to the water/temperature sensor.
SIgNATURe eDITION MICROSILK
TM
-WhIRLPOOL
PReMIeR eDITION MICROSILK-WhIRLPOOL
PARTS LIST
MicroSilk Pump Unit
MicroSilk Control Box
Pump
Pump Control Box
Control Box Stand
Water Level/Vacuum Sensor
Keypad
Keypad Cable
LED Light Assembly
LED Light Cable
Ozone Sanitation Unit
Figure 11
CONTROL bOX CONNeCTIONS (cont.)
NOTE: This diagram (Figure 11) also applies to 50 hz,
240v pumps, controls, and power supply systems. Ex-
cept that the MicroSilk and Whirlpool pump junction
boxes must be connected into one dedicated 240v, 20
Amp GFCI circuit.
NOTE: This diagram (Figure 12) also applies to 50 hz,
240v pumps, controls, and power supply systems.
Figure 12