T h e   J a s o n   S i g n a t u r e   E d i t i o n   M i c r o S i l k -

Whirlpool  digital  touchpad  is  used  to  access  all  the 

functions  of  the  two  (2)  control  boxes  used  on  the 

Jason  Signature  Edition  MicroSilk-Whirlpool  bath.  

 

NOTE: It is not recommended to operate the MicroSilk 

system at the same time as the Whirlpool system as this 

could diminish the effects of the MicroSilk system.

OPeRATINg INSTRUCTIONS
Whirlpool On/Off Icon

To control the operation of the whirlpool pump motor, press 

and release for each setting: High, Medium, Low, or Off. (For 

50Hz controls: ON or OFF) A 20 minute decreasing timer will 

be initiated when the pump motor starts. Press and hold the 

Pump icon to cycle through each pump setting. The Pump 

icon lights when the water is at operating level and the LCD 

displays “System Ready”. The LCD will display “Pump Off”, 

“Pump High”, “Pump Medium”, or “Pump Low” when the key 

is pressed. It also toggles between Temperature and Timer 

at 5 second intervals. “Low Water” is displayed for 5 seconds 

if no water is detected.

Jetted Neck Pillow Icon [Optional]

To control the operation of the jetted neck pillow, press and 

release for each setting, you can set for a constant flow on 

both jets, a pulsing flow on both jets, or a pulsing alternating 

flow between jets. Press and hold the Pillow icon to cycle 

though the various pillow settings. The Pillow icon will light 

whenever the pump is running. The solenoids will open for 

two (2) minutes to drain during the purge cycle countdown. 

The  LCD  will  display  “Pillow  On”,  “Pillow  Pulse1”,  “Pillow 

Pulse2”, or “Pillow Off” while the key is pressed.

MicroSilk On/Off

To control the operation of the MicroSilk pump motor, press 

and release for each setting: ON or OFF.  A 20 minute de-

creasing timer will be initiated when the pump motor starts. 

Press and hold the Pump icon to cycle through each pump 

setting. The Pump icon lights when the water is at operating 

level and the LCD displays “System Ready”. The LCD will 

display “Pump On”, or “Pump Off” when the key is pressed. 

It also toggles between Temperature and Timer at 5 second 

intervals. “Low Water” is displayed for 5 seconds if no water 

is  detected.  “Vacuum  Error”  is  displayed  if  the  MicroSilk 

suction is blocked.

LeD Light Icon

Hold the key for less than two (2) seconds to turn the lights 

Off or On. Hold the key for more than two (2) seconds to 

change modes. The Light icon should remain lit as long as 

the bath is connected to a power supply. This function has 

a two-hour timer and remembers the last mode. The LCD 

displays “Light On” or “Light Off while the key is pressed 

for less than two (2) seconds, “Light Cycle” is displayed if 

pressed for more than two (2) seconds.

Customized Settings

The 12 character LCD display can be customized by pressing 

the two Diagnostic Function icons simultaneously for five (5) 

seconds, while the system is off. 

Note :

 Use the above figure 

to locate the icons. A menu will be displayed to choose the 

following: Product Test Diagnostics, Temperature (F or C) 

and Language (English or Spanish).

Menu Instructions

Use the top Diagnostic Function icon to scroll through the 

different menu items. Use the bottom Diagnostic Function 

icon to change an option. For example, press and release 

the top icon to change from Product Test to the Temperature 

option. Press and release the bottom icon to change the 

temperature display from F (Fahrenheit) to C (Celsius).

Product Test Diagnostics

After  selecting  the  Product  Test  option  from  the  menu, 

the  unit  will  perform  a  series  of  tests  to  confirm  correct 

installation of components. The test will begin by displaying 

the configuration number, followed by the software revision 

number.  Next,  the  auxiliary  control  box  will  be  tested  to 

ensure proper IR communication. The display will then test 

the  Temperature  and  Low  Water  level  sensor  (ITW-209). 

Next, each of the six (6) icon buttons will begin to light. Press 

the illuminated button to proceed to the next icon. After the 

icon test, the pump will start for two (2) seconds on the High 

setting. Lastly, the LED Light unit will be tested. If you receive 

an error on any of the tests, confirm proper installation of 

component to the correct control box.  (See the 

CONTROL 

BOX CONNECTIONS 

section). 

Remote Control

The Signature Edition control system includes a waterproof 

floating Universal Remote Control. It controls all bath functions 

plus a TV, DVD, CD, etc. which can be heard through the 

Sound Immersion Transducers (optional).

SIgNATURe eDITION  

MICROSILK

TM

-WhIRLPOOL TOUChPAD

MicroSilk On/Off

Pillow On/Off

Whirlpool On/Off

LeD Light

Summary of Contents for forma AC553

Page 1: ... responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered the carrier must be immediately notified in writing with a request for a representative to inspect the unit Failure of the carrier to respond should be reported to the seller and carrier Always file a freight claim promptly If the carton shows sign of damage inspect the product before accepting...

Page 2: ...o the minimum recommended access panel size in Table 1 Specifications Table 1 Specifications 66 x 36 x 22 39 36 x 17 in 53 0 168 x 91 x 56 148 91 x 43 cm 259 72 x 36 x 22 49 36 x 17 in 55 3 183 x 91 x 56 185 91 x 43 cm 270 72 x 42 x 22 56 36 x 17 in 51 7 183 x 107 x 56 212 91 x 43 cm 252 66 x 36 x 22 44 36 x 17 in 56 3 168 x 91 x 56 167 91 x 43 cm 275 60 x 60 x 20 5 55 36 x 17 in 48 4 152 x 152 x ...

Page 3: ... related plumbing If a Jason Double CascadeTM is provided please refer to the included instructions and install at this time 5 Remove the packing board before installing the bath The bath is equipped with separate bath equipment sup port bases which are joined for shipment with packing boards Detach the packing board from the bath and from underneath the equipment WARNING Anymodificationtotheequip...

Page 4: ...form maintenance while system is running The Jason MicroSilk system has been factory assembled followingETLandIAPMOguidelines Forshippingpurposes the MicroSilk Pump Assembly is packaged separately and disconnected from the bath Note Verify the MicroSilk Pump Assembly is the same unit that was provided for the bath being installed The serialnumberlistedonthelabelprovidedontheMicroSilk Pump Assembly...

Page 5: ...end is angled to allow for proper drainage Figure 6 6 Clamp the MicroSilk Suction Line to the MicroSilk Suction Barb using the clamp provided on the tubing Assure the MicroSilk Suction Line will allow proper drainage to the suction See Figure 8 The suction hose must have a continuous drop from the suction barb to the suction fitting Caution Confirm all tubing is fully engaged on its respective bar...

Page 6: ...nsed plumber 4 Standard Premier Edition MicroSilk Whirlpool Control Box 120v The MicroSilk generator unit is shipped separate from the bath Follow the instructions for the MicroSilk Pump Assembly Field Installation in the Installation section of this owner s manual instructions are also packaged with the MicroSilk unit packaging The pump is prewired to the control box The control boxes have a 36 9...

Page 7: ...tallation the control box bracket and controls must be positioned horizontally and located to permit access for inspection and servicing The MicroSilk pump s power cord will need to be plugged into the control box Connect the pump s male J J plug to the female J J plug of the control box s load line The MicroSilk and pump junction box must be plugged into a dedicated 240v 20A 50 or 60 Hz GFCI prot...

Page 8: ... acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks Before water testing the bath make sure any pump unions 1 are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the...

Page 9: ...es all the features of the Standard Edition system and includes the benefits of a combination pump heater ozone sanitation system and an LED Chromatherapy light To assure that your bath functions properly the pump control box must be properly connected NOTE For 120v systems the power cord for the Micro Silk control box must be plugged into a 120v 20 amp GFCIdedicatedcircuit ThepowercordfortheWhirl...

Page 10: ...is manual for connecting the pump to the control box THE PUMP CONTROL BOX The Pump Keypad LED light Ozone Sanitation Unit Vac uum Switch and Water Level Temperature Sensor must be pluggedintotheproperreceptaclesforcorrectoperationofthe MicroSilk Whirlpool system See Figure 12 for connections A The junction box for the pump MicroSilk control boxes and heater must be connected into a 240v 20 amp GFC...

Page 11: ...udes both a Microbubble generator unit and a whirlpool bath system The whirlpool bath system includes a quiet 1 1 2 HP 3 speed pump Automatic 1 5kW Heater Chromatherapy mood light Automatic Ozone System that will be operated any time the pump is powered a digital control with LCD display window low water and temperature sensors flow and pressure sensors to ensure proper pump operation and a 20 min...

Page 12: ...will keep the system running properly Never operate the system without the pre filter internal filter screen and suction cover installed OPERATING INSTRUCTIONS FEATURES AND CONTROLS cont Filling and Draining Close the drain and fill the bath with water at least two 2 inches 50mm above the jets The inlet temperature should not exceed 40 C 104 F as this could damage the acrylic surface When bath is ...

Page 13: ...ol icon is used to activate the whirlpool pump and the 20 minute timer Pressing the icon the first time starts the pump Pressing the icon again will shut the pump off MicroSilk On Off Icon The MicroSilk icon is used to activate the MicroSilk pump and the 20 minute timer Pressing the icon the first time starts the pump Pressing the icon again will shut the pump off m MICROSILK wHIRLPOOL LED Light W...

Page 14: ...yed for 5 seconds if no water is detected Vacuum Error is displayed if the MicroSilk suction is blocked LED Light Icon Hold the key for less than two 2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds to change modes The Light icon should remain lit as long as the bath is connected to a power supply This function has a two hour timer and remembers the last mode The LCD...

Page 15: ...installed is well vented and allows enough ventilation and air circulation to dry the bathroom environment within a short time after taking a bath or shower 2 If your bath or shower unit is tiled in use units with an integral tile flange or make sure a tile flange kit or a similar mechanical barrier is installed to prevent shower spray splash or overflow to leak behind the bathtub 3 Make sure the ...

Page 16: ...er b Refer to installer dealer Pump operates but water is not being pumped a Suction or discharge blocked b Suction air leak System usually surges a Remove obstruction b Make sure connection is tight on suction side of the pump Pump does not manually shut off a Digital or Touch Control defective a Refer to installer dealer Pump shuts off by itself or before set time elapses a Internal filter restr...

Page 17: ...eated and thermal protection device deactivated motor Possibly low voltage b GFCI tripped c Water fell below recommended level a Make sure motor air cooling vents are not blocked Clear and allow motor to cool down Check service wire size b Refer to installer dealer c Fill to recommended level 2 above jets Pump does not turn off after set time elapses a Wiring error or control problem a Refer to in...

Page 18: ...soconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication should consult a physician before using a therapy bath since some medication may induce drowsiness while other medication may affect hea...