IMPORTANT SAFETY INSTRUCTIONS

InsTruCTIOns PerTaInIng TO The rIsK Of fIre, eleCTrIC shOCK, Or InJurY TO 

PersOns.

This manual contains information and instructions for proper operation and maintenance of your therapy bath.  Failure to 
follow these instructions could result in personal injury, electrical shock, or fire.

warnIng:  when  using  this  unit,  basic  precautions  should  always  be  followed,  including  the 

following:

reaD anD fOllOw all InsTruCTIOns CarefullY

Danger:

 

TO reDuCe The rIsK Of InJurY fOllOw These PreCauTIOns: 

a.

  Do not permit children to use this product unless they are closely supervised at all times.

B.

  Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the 

manufacturer.

C.

  The water in a  therapy bath should never exceed 40°C (104°F). Water temperatures between 38°C (100°F) and 40°C 

(104°F) are considered safe for a healthy adult. Use time should be limited to approximately 30 minutes, followed by a 
shower to cool down. Longer exposures may result in hyperthermia. The symptoms of this condition are nausea, dizzi-
ness and fainting, and it can be fatal. Lower water temperatures are recommended for extended use (exceeding 10 -15 
minutes) and for young children.

D.

  Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, 

pregnant or possibly pregnant women should limit therapy bath water temperatures to 38°C (100°F).

e.

  The  use  of  drugs  or  alcoholic  beverages  before  or  during  therapy  bath  use  may  lead  to  unconsciousness  with  the 

possibility of drowning. Never use the therapy bath while under the influence of alcohol, anticoagulants, stimulants,  
antihistamines, vasoconstrictors, vasodilators, hypnotics, narcotics, or tranquilizers.

f.

  Persons with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes 

should consult a physician before using a therapy bath.

g.

  Persons using medication should consult a physician before using a therapy bath since some medication may induce 

drowsiness while other medication may affect heart rate, blood pressure, and circulation.

Danger:

 

 

To reduce the risk of injury, enter and exit the bath slowly. 

Do not operate this unit unless the suction cover is at-

tached over the suction inlet fitting and the jet assemblies are installed.  There should be at least two (2) inches of water 
above the highest jet location during therapy bath operation.

 neVer run unIT DrY.

warnIng:

 

Never operate electrically connected devices in or near the bath. Never drop or insert any object into any opening.

This unit must be connected to a supply circuit that is protected by a GFCI. Such a device should be installed by a licensed 
electrician and should be tested on a regular basis (at least monthly). To test the GFCI push the 

TesT

 button. The GFCI 

should interrupt the power. Push the 

reseT

 button and the power should be restored. If the GFCI fails to operate in this 

manner, there is the possibility of an electric shock. 

DO nOT use. 

Disconnect the unit and have the problem corrected by a 

qualified service technician. 
To avoid the possibility of personal injury and discoloration of the acrylic surface, the inlet water temperature should not 
exceed 40°C (104°F). The bath should be drained after each use. Each bather should start their bath with fresh water. Do 
not use oil base additives in your therapy bath.

CauTIOn: 

Do not use harsh abrasives or solvents for cleaning this unit.

InsTaller/Owner Bears all resPOnsIBIlITY TO COMPlY wITh all sTaTe  

anD lOCal CODes when InsTallIng ThIs PrODuCT.

saVe These InsTruCTIOns

 

Jason InternatIonal, Inc.

8328 MacArthur Drive  •  North Little Rock  •  Arkansas  •  72118

www.jasoninternational.com 

Summary of Contents for forma AC553

Page 1: ... responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered the carrier must be immediately notified in writing with a request for a representative to inspect the unit Failure of the carrier to respond should be reported to the seller and carrier Always file a freight claim promptly If the carton shows sign of damage inspect the product before accepting...

Page 2: ...o the minimum recommended access panel size in Table 1 Specifications Table 1 Specifications 66 x 36 x 22 39 36 x 17 in 53 0 168 x 91 x 56 148 91 x 43 cm 259 72 x 36 x 22 49 36 x 17 in 55 3 183 x 91 x 56 185 91 x 43 cm 270 72 x 42 x 22 56 36 x 17 in 51 7 183 x 107 x 56 212 91 x 43 cm 252 66 x 36 x 22 44 36 x 17 in 56 3 168 x 91 x 56 167 91 x 43 cm 275 60 x 60 x 20 5 55 36 x 17 in 48 4 152 x 152 x ...

Page 3: ... related plumbing If a Jason Double CascadeTM is provided please refer to the included instructions and install at this time 5 Remove the packing board before installing the bath The bath is equipped with separate bath equipment sup port bases which are joined for shipment with packing boards Detach the packing board from the bath and from underneath the equipment WARNING Anymodificationtotheequip...

Page 4: ...form maintenance while system is running The Jason MicroSilk system has been factory assembled followingETLandIAPMOguidelines Forshippingpurposes the MicroSilk Pump Assembly is packaged separately and disconnected from the bath Note Verify the MicroSilk Pump Assembly is the same unit that was provided for the bath being installed The serialnumberlistedonthelabelprovidedontheMicroSilk Pump Assembly...

Page 5: ...end is angled to allow for proper drainage Figure 6 6 Clamp the MicroSilk Suction Line to the MicroSilk Suction Barb using the clamp provided on the tubing Assure the MicroSilk Suction Line will allow proper drainage to the suction See Figure 8 The suction hose must have a continuous drop from the suction barb to the suction fitting Caution Confirm all tubing is fully engaged on its respective bar...

Page 6: ...nsed plumber 4 Standard Premier Edition MicroSilk Whirlpool Control Box 120v The MicroSilk generator unit is shipped separate from the bath Follow the instructions for the MicroSilk Pump Assembly Field Installation in the Installation section of this owner s manual instructions are also packaged with the MicroSilk unit packaging The pump is prewired to the control box The control boxes have a 36 9...

Page 7: ...tallation the control box bracket and controls must be positioned horizontally and located to permit access for inspection and servicing The MicroSilk pump s power cord will need to be plugged into the control box Connect the pump s male J J plug to the female J J plug of the control box s load line The MicroSilk and pump junction box must be plugged into a dedicated 240v 20A 50 or 60 Hz GFCI prot...

Page 8: ... acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks Before water testing the bath make sure any pump unions 1 are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the...

Page 9: ...es all the features of the Standard Edition system and includes the benefits of a combination pump heater ozone sanitation system and an LED Chromatherapy light To assure that your bath functions properly the pump control box must be properly connected NOTE For 120v systems the power cord for the Micro Silk control box must be plugged into a 120v 20 amp GFCIdedicatedcircuit ThepowercordfortheWhirl...

Page 10: ...is manual for connecting the pump to the control box THE PUMP CONTROL BOX The Pump Keypad LED light Ozone Sanitation Unit Vac uum Switch and Water Level Temperature Sensor must be pluggedintotheproperreceptaclesforcorrectoperationofthe MicroSilk Whirlpool system See Figure 12 for connections A The junction box for the pump MicroSilk control boxes and heater must be connected into a 240v 20 amp GFC...

Page 11: ...udes both a Microbubble generator unit and a whirlpool bath system The whirlpool bath system includes a quiet 1 1 2 HP 3 speed pump Automatic 1 5kW Heater Chromatherapy mood light Automatic Ozone System that will be operated any time the pump is powered a digital control with LCD display window low water and temperature sensors flow and pressure sensors to ensure proper pump operation and a 20 min...

Page 12: ...will keep the system running properly Never operate the system without the pre filter internal filter screen and suction cover installed OPERATING INSTRUCTIONS FEATURES AND CONTROLS cont Filling and Draining Close the drain and fill the bath with water at least two 2 inches 50mm above the jets The inlet temperature should not exceed 40 C 104 F as this could damage the acrylic surface When bath is ...

Page 13: ...ol icon is used to activate the whirlpool pump and the 20 minute timer Pressing the icon the first time starts the pump Pressing the icon again will shut the pump off MicroSilk On Off Icon The MicroSilk icon is used to activate the MicroSilk pump and the 20 minute timer Pressing the icon the first time starts the pump Pressing the icon again will shut the pump off m MICROSILK wHIRLPOOL LED Light W...

Page 14: ...yed for 5 seconds if no water is detected Vacuum Error is displayed if the MicroSilk suction is blocked LED Light Icon Hold the key for less than two 2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds to change modes The Light icon should remain lit as long as the bath is connected to a power supply This function has a two hour timer and remembers the last mode The LCD...

Page 15: ...installed is well vented and allows enough ventilation and air circulation to dry the bathroom environment within a short time after taking a bath or shower 2 If your bath or shower unit is tiled in use units with an integral tile flange or make sure a tile flange kit or a similar mechanical barrier is installed to prevent shower spray splash or overflow to leak behind the bathtub 3 Make sure the ...

Page 16: ...er b Refer to installer dealer Pump operates but water is not being pumped a Suction or discharge blocked b Suction air leak System usually surges a Remove obstruction b Make sure connection is tight on suction side of the pump Pump does not manually shut off a Digital or Touch Control defective a Refer to installer dealer Pump shuts off by itself or before set time elapses a Internal filter restr...

Page 17: ...eated and thermal protection device deactivated motor Possibly low voltage b GFCI tripped c Water fell below recommended level a Make sure motor air cooling vents are not blocked Clear and allow motor to cool down Check service wire size b Refer to installer dealer c Fill to recommended level 2 above jets Pump does not turn off after set time elapses a Wiring error or control problem a Refer to in...

Page 18: ...soconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication should consult a physician before using a therapy bath since some medication may induce drowsiness while other medication may affect hea...

Reviews: