INSTALLATION INSTRUCTIONS (cont.)

eLeCTRICAL

ELECTRICAL  POWER  SUPPLY:

    These  instructions  are 

written assuming 60Hz, 120v (or 240v for Signature Edition) 
power  supply.    Special  notations  are  also  included  for  the 
Export versions of the pump, control equipment, and power 
supply.

Danger:

WARNING

vERIFICATION OF ELECTRICAL REqUIRE-

MENTS MUST BE MADE BEFORE INSTALLATION. RE-

FER TO ThE EqUIPMENT LABELS FOR vOLTAGE AND 

FREqUENCY REqUIREMENTS.

NOTE:    verify  that  the  electrical  system  of  the  bath 

matches the 120v (or 240v for Signature Edition) power 

supply.

NOTE:  The  bath  is  designed  for  indoor  use  only.  The 

electrical  equipment  must  not  be  exposed  to  direct 

or  indirect  water  or  moisture  contact.  The  electrical 

equipment must also be protected from dust and other 

airborne debris before, during, and after installation.

1.  Electrical Service: A licensed electrician must provide the 

“dedicated” electrical service protected by a GFCI. The 
location of the GFCI must be at least five (5) feet (152 cm) 
away from the inside surface of the bath, accessible for 
regular testing. Use copper conductors only.

DANGER — RISK OF ELECTRIC ShOCK: 

Connect only 

to a circuit protected by a Ground Fault Circuit Interrupter 
(GFCI). In the unlikely occurrence of a current imbalance 
in the power conductors, the GFCI will interrupt the power 
to the bath.

WARNING:  ThE  ELECTRICAL  SERvICE  TO  ThE 

GFCI  MUST  NOT  BE  INTERRUPTED  BY  ANY 

CONTROL  DEvICE.  LIKEWISE,  ThE  ELECTRICAL 

SERvICE FROM ThE GFCI TO ThE BATh CONTROL 

ShOULD BE DIRECT AND NOT INTERRUPTED BY A 

SWITCh. NEvER USE A SWITCh IN CONJUNCTION 

WITh  A  CONTROL  DEvICE.  ThIS  WILL  vOID  ThE 

MANUFACTURER’S WARRANTY.

2. 

GROUNDING  IS  REqUIRED.

    The  unit  should  be 

installed by a qualified service representative and properly 
grounded.

3.  INSTALL SERVICE CONNECTION AT LEAST 6” (15cm) 

ABOVE SUB FLOOR.

ALL LOCAL AND STATE ELECTRICAL AND PLUMBING 

CODES  MUST  BE  OBSERvED.

 

Where  there  are  no 

local  codes  the  National  Electric  Code  (NEC)  and 

Uniform Plumbing Code (UPC) shall be observed. It is 

the responsibility of the installer/owner to determine 

specific code compliance prior to installation of the 

product.

NOTE:  In  the  Commonwealth  of  Massachusetts, 

installation is to be done by a Massachusetts licensed 

plumber.

4. 

Standard/Premier  Edition  MicroSilk™-Whirlpool 

Control  Box  (120v).

  The  MicroSilk  generator  unit  is 

shipped separate from the bath. Follow the instructions 
for  the 

MicroSilk  Pump  Assembly  Field  Installation

 

in  the 

INSTALLATION

  section  of  this  owner’s  manual 

(instructions  are  also  packaged  with  the  MicroSilk  unit 
packaging).  The  pump  is  prewired  to  the  control  box. 
The control boxes have a 36” (91cm) cord with plug end. 
The MicroSilk and pump control boxes are mounted on a 
stand that is temporarily secured to the packing board for 
shipping.  These  boxes  must  remain  on  the  control  box 
bracket so that the two boxes can communicate properly 
through  their  infrared  communication  feature.  During 
installation, the control box bracket and controls must be 
positioned horizontally and located to permit access for 
inspection  and  servicing.  The  MicroSilk  pump’s  power 
cord will need to be plugged into the control box.  Connect 
the pump’s male NEMA plug to the female NEMA plug of 
the control box’s load line.  The MicroSilk control must be 
plugged into a dedicated 120v, 20A, 60Hz, GFCI protected 
circuit and the pump control must be plugged into another 
dedicated 120v, 20A, 60Hz, GFCI protected circuit. 

(See 

Figure 9)

On Standard Edition baths, if an optional 1kw (kilowatt) 
heater is operated with this control, then the pump control 
and  heater  must  be  wired  into  a  dedicated  30A  (amp) 
service. NOTE: The pump and MicroSilk dedicated circuits 
must only power their specified controls.

5. 

Standard/Premier  Edition  MicroSilk™  Control 

Box  (240v).

  The  MicroSilk  generator  unit  is  shipped 

separate  from  the  bath.  Follow  the  instructions  for  the 

MicroSilk  Pump  Assembly  Field  Installation

  in 

the 

INSTALLATION 

section  of  this  owner’s  manual 

(instructions  are  also  packaged  with  the  MicroSilk  unit 
packaging).  The  pump  is  prewired  to  the  control  box. 
The control boxes have a 36” (91cm) cord with plug end. 
The MicroSilk and pump control boxes are mounted on a 
stand that is temporarily secured to the packing board for 
shipping.  These  boxes  must  remain  on  the  control  box 
bracket so that the two boxes can communicate properly 
through  their  infrared  communication  feature.  During 
installation, the control box bracket and controls must be 
positioned horizontally and located to permit access for 
inspection and servicing. The MicroSilk pump’s power cord 
will need to be plugged into the control box.  Connect the 
pump’s male J+J plug to the female J+J plug of the control 
box’s load line.  The MicroSilk control must be plugged into 

Summary of Contents for forma AC553

Page 1: ... responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered the carrier must be immediately notified in writing with a request for a representative to inspect the unit Failure of the carrier to respond should be reported to the seller and carrier Always file a freight claim promptly If the carton shows sign of damage inspect the product before accepting...

Page 2: ...o the minimum recommended access panel size in Table 1 Specifications Table 1 Specifications 66 x 36 x 22 39 36 x 17 in 53 0 168 x 91 x 56 148 91 x 43 cm 259 72 x 36 x 22 49 36 x 17 in 55 3 183 x 91 x 56 185 91 x 43 cm 270 72 x 42 x 22 56 36 x 17 in 51 7 183 x 107 x 56 212 91 x 43 cm 252 66 x 36 x 22 44 36 x 17 in 56 3 168 x 91 x 56 167 91 x 43 cm 275 60 x 60 x 20 5 55 36 x 17 in 48 4 152 x 152 x ...

Page 3: ... related plumbing If a Jason Double CascadeTM is provided please refer to the included instructions and install at this time 5 Remove the packing board before installing the bath The bath is equipped with separate bath equipment sup port bases which are joined for shipment with packing boards Detach the packing board from the bath and from underneath the equipment WARNING Anymodificationtotheequip...

Page 4: ...form maintenance while system is running The Jason MicroSilk system has been factory assembled followingETLandIAPMOguidelines Forshippingpurposes the MicroSilk Pump Assembly is packaged separately and disconnected from the bath Note Verify the MicroSilk Pump Assembly is the same unit that was provided for the bath being installed The serialnumberlistedonthelabelprovidedontheMicroSilk Pump Assembly...

Page 5: ...end is angled to allow for proper drainage Figure 6 6 Clamp the MicroSilk Suction Line to the MicroSilk Suction Barb using the clamp provided on the tubing Assure the MicroSilk Suction Line will allow proper drainage to the suction See Figure 8 The suction hose must have a continuous drop from the suction barb to the suction fitting Caution Confirm all tubing is fully engaged on its respective bar...

Page 6: ...nsed plumber 4 Standard Premier Edition MicroSilk Whirlpool Control Box 120v The MicroSilk generator unit is shipped separate from the bath Follow the instructions for the MicroSilk Pump Assembly Field Installation in the Installation section of this owner s manual instructions are also packaged with the MicroSilk unit packaging The pump is prewired to the control box The control boxes have a 36 9...

Page 7: ...tallation the control box bracket and controls must be positioned horizontally and located to permit access for inspection and servicing The MicroSilk pump s power cord will need to be plugged into the control box Connect the pump s male J J plug to the female J J plug of the control box s load line The MicroSilk and pump junction box must be plugged into a dedicated 240v 20A 50 or 60 Hz GFCI prot...

Page 8: ... acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks Before water testing the bath make sure any pump unions 1 are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the...

Page 9: ...es all the features of the Standard Edition system and includes the benefits of a combination pump heater ozone sanitation system and an LED Chromatherapy light To assure that your bath functions properly the pump control box must be properly connected NOTE For 120v systems the power cord for the Micro Silk control box must be plugged into a 120v 20 amp GFCIdedicatedcircuit ThepowercordfortheWhirl...

Page 10: ...is manual for connecting the pump to the control box THE PUMP CONTROL BOX The Pump Keypad LED light Ozone Sanitation Unit Vac uum Switch and Water Level Temperature Sensor must be pluggedintotheproperreceptaclesforcorrectoperationofthe MicroSilk Whirlpool system See Figure 12 for connections A The junction box for the pump MicroSilk control boxes and heater must be connected into a 240v 20 amp GFC...

Page 11: ...udes both a Microbubble generator unit and a whirlpool bath system The whirlpool bath system includes a quiet 1 1 2 HP 3 speed pump Automatic 1 5kW Heater Chromatherapy mood light Automatic Ozone System that will be operated any time the pump is powered a digital control with LCD display window low water and temperature sensors flow and pressure sensors to ensure proper pump operation and a 20 min...

Page 12: ...will keep the system running properly Never operate the system without the pre filter internal filter screen and suction cover installed OPERATING INSTRUCTIONS FEATURES AND CONTROLS cont Filling and Draining Close the drain and fill the bath with water at least two 2 inches 50mm above the jets The inlet temperature should not exceed 40 C 104 F as this could damage the acrylic surface When bath is ...

Page 13: ...ol icon is used to activate the whirlpool pump and the 20 minute timer Pressing the icon the first time starts the pump Pressing the icon again will shut the pump off MicroSilk On Off Icon The MicroSilk icon is used to activate the MicroSilk pump and the 20 minute timer Pressing the icon the first time starts the pump Pressing the icon again will shut the pump off m MICROSILK wHIRLPOOL LED Light W...

Page 14: ...yed for 5 seconds if no water is detected Vacuum Error is displayed if the MicroSilk suction is blocked LED Light Icon Hold the key for less than two 2 seconds to turn the lights Off or On Hold the key for more than two 2 seconds to change modes The Light icon should remain lit as long as the bath is connected to a power supply This function has a two hour timer and remembers the last mode The LCD...

Page 15: ...installed is well vented and allows enough ventilation and air circulation to dry the bathroom environment within a short time after taking a bath or shower 2 If your bath or shower unit is tiled in use units with an integral tile flange or make sure a tile flange kit or a similar mechanical barrier is installed to prevent shower spray splash or overflow to leak behind the bathtub 3 Make sure the ...

Page 16: ...er b Refer to installer dealer Pump operates but water is not being pumped a Suction or discharge blocked b Suction air leak System usually surges a Remove obstruction b Make sure connection is tight on suction side of the pump Pump does not manually shut off a Digital or Touch Control defective a Refer to installer dealer Pump shuts off by itself or before set time elapses a Internal filter restr...

Page 17: ...eated and thermal protection device deactivated motor Possibly low voltage b GFCI tripped c Water fell below recommended level a Make sure motor air cooling vents are not blocked Clear and allow motor to cool down Check service wire size b Refer to installer dealer c Fill to recommended level 2 above jets Pump does not turn off after set time elapses a Wiring error or control problem a Refer to in...

Page 18: ...soconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication should consult a physician before using a therapy bath since some medication may induce drowsiness while other medication may affect hea...