GENERAL OPERATING INSTRUCTIONS

INTRODUCTION

This  manual  contains  all  of  the  information  needed  for  the 

proper installation and operation of your Jason AirMasseur

®

 

bath.  The  AirMasseur

®

  bath  has  been  designed  to  give 

you  years  of  relaxing  trouble-free  service,  provided  the 

unit  is  maintained  and  operated  in  accordance  with  these 

instructions.

Thoroughly clean and disinfect the unit as described in the 

CleaNING

 section of the 

user MaINTeNaNCe INsTruCTIONs

 on  

page 13 before its first use and periodically thereafter.

All Jason air baths are pre-plumbed at the factory.

WARNING: Before operating refer to the instructions pertaining to the 

risk of fire, electric shock, or injury to persons.

fILLING AND DRAINING

Close the drain and fill the bath with water to at least 10” below 

the bath deck. The inlet temperature should not exceed 40°C 

(104°F) as this could damage the acrylic surface.

When the bath is in use, turn the unit 

Off

 before draining the 

water. The bath unit and its plumbing are designed to drain 

after each use whether used as an air bath, soaking bath, or 

just taking a shower.

bLOwER

The  blower  generates  the  warm  air  and  pushes  it  through 

the air jets. Blowers provided on Jason air baths are factory 

tested when assembled and retested after installation on the 

AirMasseur

®

 bath.

STANDARD EDITION AUTOMATIC PURGE

Fifteen minutes after the control has shut off and the bath is 

completely drained, the blower will start again for a 2-minute 

purge cycle that dries the air channel. Note that the blower light 

will flash during the 15-minute pause before the purge cycle 

begins. Once the purge cycle begins, all indicators will light and 

the keypad operation will be disabled for two (2) minutes.

SIGNATURE EDITION AUTOMATIC PURGE

Twenty (20) minutes after the control has shut off and the bath 

is completely drained, the blower will start again for a 2-minute 

purge  cycle  that  dries  the  air  channel.  Note  that  the  LCD 

display will read “PURGE” and begin to countdown the 10 or 

20 minute pause before the purge cycle begins. The readout 

will display “PURGE ON” during the purge cycle. 

Any  time  during  the  pause  before  the  purge  cycle  begins, 

pressing and holding the Blower Speeds icon will reduce the 

pause  from  20  minutes  to  10  minutes.  During  the  2-minute 

purge, pressing the “Blower On/Off” icon will stop the purge.

SIGNATURE EDITION DAILY PURGE

The  Daily  Purge  can  be  activated  through  the  customized 

settings  of  the  Signature  Edition  touchpad.  When  activated 

the daily purge will start the blower for 2-minutes at the same 

time everyday to dry out the air channel. See ‘Operating the 

Signature Edition AirMasseur

®

 Touchpad’ section on page 12 

for details on activating this setting.

INITALIZATION Of SIGNATURE EDITION CONTROL 
SYSTEM

The blower junction box must be connected to its dedicated 

service prior to filling the bath with water. This will assure the 

control box is properly initialized. (See Figure 12 on page 9.)

SIGNATURE  EDITION  UNIVERSAL  REMOTE 
CONTROL

In addition to the main control console installed on the bath 

deck,  a  floating,  waterproof  Universal  Remote  Control  is 

provided  with  all  Signature  Edition  AirMasseur

®

  baths.  This 

remote control is capable of operating the same functions as 

the bath’s main control console, plus the bather may remotely 

operate a TV, DVD, CD, etc. Refer to the Instruction Manual 

provided with the remote control for detailed instructions.

NOTe:

 If the unit fails to operate, check the breaker panel to 

insure that the circuit breaker is on. Check the GFCI by testing 

and  resetting  it.  If  the  unit  still  fails  to  operate,  refer  to  the 

Trouble Shooting Guide section on page 14 of this manual. 

If the unit still fails to operate and is out of warranty, contact 

an  authorized  service  technician  for  repair.  If  the  unit  is  in 

warranty, contact JASON Technical Services at 800-255-5766. 

DO NOT ATTEMPT TO RESOLVE THE PROBLEM.

Summary of Contents for Forma AirMasseur AC635P

Page 1: ...llation will not be covered by warranty and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE 49 1000 113 Date 11 07 MUST BE MADE PRIOR TO INSTALLATION Inspect plumbing and bath surface for missing or damaged components Alert your dealer of any discrepancies To protect the unit from damage keep the unit in its carton until ready for installation EQUIPMENT ACCESS ...

Page 2: ...ed according to the instructions herein 5 Aninstallationtemplateisprovidedtolocatethefloordrain location sump area location remote blower tubing floor cutout location water inlet stub out location mounting holes and skirt center lines Tape the template to the sub floor in its desired location 6 Mark on the sub floor the sump area location the water inlet stub out location and the remote blower tub...

Page 3: ...netheproperfittothebath NOTE Itisrecommended that the Geberit drain and overflow model 150 176 be used If any other drain is used it may not conform to these instructions Drain Not Included This drain can be purchased from Figure 3 any authorized Jason International Inc dealer Position the bath in place and attach the drain and overflow to the floor drain P trap CAUTION Only dry fit the drain and ...

Page 4: ...OTE MOUNTING of air blower Do not remote mount the blower and control box more than 15 feet away from the air inlet of the bath Choose a location as close as possible to the bath to assure maximum efficiency 1 The installer is to determine the layout of the piping exact remote mount location and service access before beginning any work Use1 5 ABSorPVCplastictubing Locatethecontrolbox with the blow...

Page 5: ... Instructions section on page 11 or 12 for testing Faucetry connections should also be tested for leaks at this time 9 Remove the 2 x 4 boards and lower the bath into the skirt WARNING When you lower the bath into the skirt do not allow the hose sections to bind Align the drain and overflow with the corresponding bath holes and the bath brackets with the pre drilled holes in the skirt See Figure 8...

Page 6: ...edwiththeuseofawood edge trowel Paint or tar stains may need to be removed with a cleaner such as paint thinner turpentine or isopropyl alcohol rubbing alcohol Never allow the cleaner to soak against the surface for long periods of time Always rinse the surface immediately following the use of cleaners NOTE Follow the manufacturers instructions for safely using these or similar products If the sur...

Page 7: ... 6 ABOVE SUB FLOOR A licensed electrician must provide the dedicated electrical service protected by a GFCI The location of the GFCI must be at least five 5 feet away from the inside surface of the bath and accessible for regular testing Use copper conductors only DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit Interrupter GFCI In the unlikely occurrence...

Page 8: ...bath from bacteria viruses etc while leaving the plumbing lines clean and fresh The ozone system works automatically in conjunction with the blower motor TOUCHPAD FEATURES A main control touchpad mounted on the bath deck features an LCD readout which alternately indicates the water temperature 5 F and air bath time remaining The touchpad operates all functions of the blower as well as the LED Mood...

Page 9: ...th industry The blower control box must be properly connected for the bath to function correctly THE BLOWER CONTROL BOX The blower keypad LED light ozone sanitation unit and temperature sensor must be plugged into the proper receptacles for correct operation of the AirMasseur system See Figure 12 for connections A The junction box for the blower control box must be connected into a 240v 15 amp GFC...

Page 10: ...and the bath is completely drained the blower will start again for a 2 minute purge cycle that dries the air channel Note that the LCD display will read PURGE and begin to countdown the 10 or 20 minute pause before the purge cycle begins The readout will display PURGE ON during the purge cycle Any time during the pause before the purge cycle begins pressing and holding the Blower Speeds icon will ...

Page 11: ...by a slow flashing light Pressing the icon again will change the blower to Pulse mode This is indicated by a rapid light flash Pressing the icon a third time moves the blower back to Constant mode Blower Speeds Icon The Blower Speeds icon is used to increase or decrease the blower speed once the blower is on Press and hold the icon to decrease the blower speed until the desired inten sity is reach...

Page 12: ...his function has a 2 hour timer and remembers the last mode The LCD displays Light On or Light Off while the key is pressed for less than 2 seconds Light Cycle is displayed if pressed for more than 2 seconds OPTION ICON This key is reserved for future options CUSTOMIZED SETTINGS The12characterLCDdisplaycanbecustomizedbypressing the Blower and Blower Speeds icons simultaneously for 5 seconds while ...

Page 13: ...olution i e glass cleaner and a soft wet cloth or sponge Do not run the air system with foaming cleaners or soaps Rinse the bath thoroughly after cleaning SURFACE MAINTENANCE Areas with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jason dealer followed by an application of acrylic paste wax Buff t...

Page 14: ...fuses and replace if bad b Make sure plug is fully inserted into the outlet c Check and reconnect if necessary Blower shut off by itself or before time elapses a Blower motor overheated and thermal protection device deactivated motor possibly low voltage b GFCI tripped a Check that blower has sufficient ventillation and that the intake into the blower is not blocked Clear and allow the motor to co...

Page 15: ...ng Never use the therapy bath while under the influence of alcohol anticoagulants stimulants antihis tamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication should consult a physicia...