OPERATING ThE SIGNATURE EDITION AIRMASSEUR

®

 

TOUChPAD

fEATURES

The Jason Signature Edition Digital AirMasseur

®

 touchpad 

is used to access all of the functions of the control box used 

in a Jason Signature Edition AirMasseur

®

 bath. 

OPERATING INSTRUCTIONS:

bLOwER ON/Off, MODES ICON

To control the operation of the Blower, simply press and hold 

the key to change the setting to Constant, Wave, Pulse or 

Off. A 20 minute decreasing timer will be initiated when the 

blower motor starts. Press and release the Blower icon once 

to display the current blower mode and speed. The Blower 

icon should remain lit as long as the bath is connected to a 

power supply. The LCD will display “Const Air” and blower 

speed,  “Wave  Air”  and  blower  speed,  or  “Pulse  Air”  and 

blower speed, while the key is pressed. The time remaining 

on the purge cycle is displayed after the bath has drained. 

“Purge  Stop”  is  displayed  while  the  Blower  On/Off  key  is 

pressed during the purge cycle. This action will terminate 

the purge cycle. The mode settings will be remembered on 

the next startup.

bLOwER SPEEDS ICON

Hold the key in Constant mode to go from High to Low then 

release and hold again to go from Low to High. Hold the key 

in Wave and Pulse mode to go from High to Medium and 

Medium to High. The system remembers the last speed setting 

on the next startup. The icon will light up when the blower is 

running. The LED displays the blower speed from “10” (Low) 

or “55” (Med) to “99” (High) while the key is pressed. You 

can reduce the auto purge idle time from 20 minutes to 10 

minutes, by pressing and holding the Blower Speeds key for 

more than 5-seconds during the purge idle period.

LED LIGhT (LIGhT ICON)

Hold the key for less than 2 seconds to turn the lights off 

or  on.  Hold  the  key  for  more  than  2  seconds  to  change 

modes. The Light icon should remain lit as long as the bath 

is connected to a power supply. This function has a 2 hour 

timer and remembers the last mode. The LCD displays “Light 

On” or “Light Off” while the key is pressed for less than 2 

seconds. “Light Cycle” is displayed if pressed for more than 

2 seconds. 

OPTION ICON

This key is reserved for future options.

CUSTOMIZED SETTINGS

The 12 character LCD display can be customized by pressing 

the Blower and Blower Speeds icons simultaneously for 5 

seconds, while the system is Off. Note: The Blower Speeds 

icon  will  not  be  illuminated  during  this  process.  Use  the 

above figure to locate the icon. A menu will be displayed to 

choose the following: Purge 24, (starts blower every 24 hours 

for 2 minutes at the time the purge was set); Product Test 

Diagnostics; Temperature (F or C); and Language (English 

or Spanish).

MENU INSTRUCTIONS

Use  the  Blower  icon  to  scroll  through  the  different  menu 

items.  Use  the  Blower  Speeds  icon  to  change  an  option. 

For example, press and release the Blower icon to change 

from Purge 24 to Product Test; press and release again to 

arrive at the Temperature option. Then press and release 

the Blower Speeds icon to change the temperature display 

from F (Fahrenheit) to C (Celsius).

PRODUCT TEST DIAGNOSTICS

After selecting the Product Test option from the menu, the unit 

will perform a series of tests to confirm correct installation of 

components. The test will begin by displaying the configuration 

number,  followed  by  the  software  revision  number.  Next, 

the display will test the Temperature and Low Water Level 

sensor (ITW-209). Next, each of the six (6) icon buttons will 

begin to light. Press the illuminated button to proceed to the 

next icon. After the icon test, the blower will start for two (2) 

seconds on the high setting. Lastly, the LED Light unit will 

be tested. If you receive an error on any of the tests, confirm 

proper installation of the component to the correct control 

box. (See Figure 12 on page 9.)

REMOTE CONTROL

The Signature Edition control system includes a waterproof 

floating universal remote. It controls all bath functions plus 

a TV, DVD, CD, etc. which can be heard through the Sound 
Immersion Transducers (optional).

Figure 14

Blower On/Off, Modes

Blower Speeds

LED Light

IR for Remote

Summary of Contents for Forma AirMasseur AC635P

Page 1: ...llation will not be covered by warranty and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE 49 1000 113 Date 11 07 MUST BE MADE PRIOR TO INSTALLATION Inspect plumbing and bath surface for missing or damaged components Alert your dealer of any discrepancies To protect the unit from damage keep the unit in its carton until ready for installation EQUIPMENT ACCESS ...

Page 2: ...ed according to the instructions herein 5 Aninstallationtemplateisprovidedtolocatethefloordrain location sump area location remote blower tubing floor cutout location water inlet stub out location mounting holes and skirt center lines Tape the template to the sub floor in its desired location 6 Mark on the sub floor the sump area location the water inlet stub out location and the remote blower tub...

Page 3: ...netheproperfittothebath NOTE Itisrecommended that the Geberit drain and overflow model 150 176 be used If any other drain is used it may not conform to these instructions Drain Not Included This drain can be purchased from Figure 3 any authorized Jason International Inc dealer Position the bath in place and attach the drain and overflow to the floor drain P trap CAUTION Only dry fit the drain and ...

Page 4: ...OTE MOUNTING of air blower Do not remote mount the blower and control box more than 15 feet away from the air inlet of the bath Choose a location as close as possible to the bath to assure maximum efficiency 1 The installer is to determine the layout of the piping exact remote mount location and service access before beginning any work Use1 5 ABSorPVCplastictubing Locatethecontrolbox with the blow...

Page 5: ... Instructions section on page 11 or 12 for testing Faucetry connections should also be tested for leaks at this time 9 Remove the 2 x 4 boards and lower the bath into the skirt WARNING When you lower the bath into the skirt do not allow the hose sections to bind Align the drain and overflow with the corresponding bath holes and the bath brackets with the pre drilled holes in the skirt See Figure 8...

Page 6: ...edwiththeuseofawood edge trowel Paint or tar stains may need to be removed with a cleaner such as paint thinner turpentine or isopropyl alcohol rubbing alcohol Never allow the cleaner to soak against the surface for long periods of time Always rinse the surface immediately following the use of cleaners NOTE Follow the manufacturers instructions for safely using these or similar products If the sur...

Page 7: ... 6 ABOVE SUB FLOOR A licensed electrician must provide the dedicated electrical service protected by a GFCI The location of the GFCI must be at least five 5 feet away from the inside surface of the bath and accessible for regular testing Use copper conductors only DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit Interrupter GFCI In the unlikely occurrence...

Page 8: ...bath from bacteria viruses etc while leaving the plumbing lines clean and fresh The ozone system works automatically in conjunction with the blower motor TOUCHPAD FEATURES A main control touchpad mounted on the bath deck features an LCD readout which alternately indicates the water temperature 5 F and air bath time remaining The touchpad operates all functions of the blower as well as the LED Mood...

Page 9: ...th industry The blower control box must be properly connected for the bath to function correctly THE BLOWER CONTROL BOX The blower keypad LED light ozone sanitation unit and temperature sensor must be plugged into the proper receptacles for correct operation of the AirMasseur system See Figure 12 for connections A The junction box for the blower control box must be connected into a 240v 15 amp GFC...

Page 10: ...and the bath is completely drained the blower will start again for a 2 minute purge cycle that dries the air channel Note that the LCD display will read PURGE and begin to countdown the 10 or 20 minute pause before the purge cycle begins The readout will display PURGE ON during the purge cycle Any time during the pause before the purge cycle begins pressing and holding the Blower Speeds icon will ...

Page 11: ...by a slow flashing light Pressing the icon again will change the blower to Pulse mode This is indicated by a rapid light flash Pressing the icon a third time moves the blower back to Constant mode Blower Speeds Icon The Blower Speeds icon is used to increase or decrease the blower speed once the blower is on Press and hold the icon to decrease the blower speed until the desired inten sity is reach...

Page 12: ...his function has a 2 hour timer and remembers the last mode The LCD displays Light On or Light Off while the key is pressed for less than 2 seconds Light Cycle is displayed if pressed for more than 2 seconds OPTION ICON This key is reserved for future options CUSTOMIZED SETTINGS The12characterLCDdisplaycanbecustomizedbypressing the Blower and Blower Speeds icons simultaneously for 5 seconds while ...

Page 13: ...olution i e glass cleaner and a soft wet cloth or sponge Do not run the air system with foaming cleaners or soaps Rinse the bath thoroughly after cleaning SURFACE MAINTENANCE Areas with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jason dealer followed by an application of acrylic paste wax Buff t...

Page 14: ...fuses and replace if bad b Make sure plug is fully inserted into the outlet c Check and reconnect if necessary Blower shut off by itself or before time elapses a Blower motor overheated and thermal protection device deactivated motor possibly low voltage b GFCI tripped a Check that blower has sufficient ventillation and that the intake into the blower is not blocked Clear and allow the motor to co...

Page 15: ...ng Never use the therapy bath while under the influence of alcohol anticoagulants stimulants antihis tamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication should consult a physicia...