ELECTRICAL
NOTe:
The bath is designed for indoor use only. The
electrical equipment must not be exposed to direct or
indirect water or moisture contact. The electrical equipment
must also be protected from dust and other airborne debris
before, during, and after installation.
Standard Edition AirMasseur
®
The blower is prewired to its control box. The control box
has a 36” cord with a plug end. The AirMasseur
®
control box
is mounted on a stand. This stand is temporarily secured
to the packing board for shipping. During installation, the
control box and mount must be positioned horizontally and
located to permit access for inspection and servicing. The
AirMasseur
®
control box must be plugged into a dedicated
120v (volt), 15A (amp), 60Hz (hertz), Ground Fault Circuit
Interrupter (GFCI) protected circuit.
Signature Edition AirMasseur
®
The blower is prewired to its control box with a 36” cord.
The AirMasseur
®
control box is mounted on a stand. During
installation, the control box and mount must be positioned
horizontally and located to permit access for inspection and
servicing. The AirMasseur
®
control box must be connected
to a dedicated 240v (volt), 15A (amp), 60Hz (hertz), Ground
Fault Circuit Interrupter (GFCI) protected circuit.
INsTall serVICe CONNeCTION aT leasT 6” aBOVe suB
FLOOR.
A licensed electrician must provide the “dedicated” electrical
service protected by a GFCI. The location of the GFCI
must be at least five (5) feet away from the inside surface
of the bath and accessible for regular testing.
Use copper
conductors only.
DaNGer — rIsK OF eleCTrIC sHOCK:
Connect only to a
circuit protected by a Ground Fault Circuit Interrupter (GFCI).
In the unlikely occurrence of a current imbalance in the
power conductors, the GFCI will interrupt the power to the
bath.
GrOuNDING Is reQuIreD
The unit should be installed by a qualified service representative
and properly grounded.
WARNING: The electrical service to the GFCI must not be interrupted
by any control device.
Likewise, the electrical service from the
GFCI to the bath control should be direct and not interrupted
by a switch. Never use a switch in conjunction with a control
device. This will
VOID THE MANUFACTURER’S WARRANTY.
DANGER: Do not alter the factory installed wiring.
All building
materials and wiring should be routed away from the blower
body or other heat-producing components of the unit.
all lOCal aND sTaTe eleCTrICal aND PluMBING CODes
MUST BE OBSERVED.
Where there are no local codes the
National Electric Code (NEC)
and
Uniform Plumbing Code (UPC)
shall be observed. It is the responsibility of the installer/owner
to determine specific code compliance prior to installation of
the product.
NOTe:
In the Commonwealth of Massachusetts,
installation is to be done by a Massachusetts licensed
plumber.