fEATURES Of ThE DESIGNER AIRMASSEUR

®

 

bATh

bLOwER fEATURES

The Jason Standard Edition AirMasseur

®

 system provides 

a variable speed, controlled heated air blower with three (3) 

massage modes: continuous, wave, and pulse.

STANDARD EDITION AIRMASSEUR

®

TOUChPAD fEATURES

One main control touchpad mounted on the bath deck 

contains several icons used by the bather to control the 

blower and optional light. A built in timer shuts the blower 

off 20 minutes after being activated. A purge cycle will 

automatically start the blower again for 2 minutes, 15 

minutes after the bath has been shut off. This should be 

done in order to dry out the air channels.

bLOwER fEATURES

The Jason Signature Edition AirMasseur

®

 

air bath system 

includes a variable-speed, 1-HP air blower with heater; 

three (3) massage modes: continuous, wave, or pulse; and 

temperature sensors. A built in timer shuts the blower off 20 

minutes after being activated.
Also included is the Automatic Ozone Sanitation system to 

guard your bath from bacteria, viruses, etc. while leaving the 

plumbing lines clean and fresh.  The ozone system works 

automatically in conjunction with the blower motor.

TOUChPAD fEATURES

A  main  control  touchpad  mounted  on  the  bath  deck 

features an LCD readout which alternately indicates the 

water temperature (+/- 5°F) and air bath time remaining. 

The touchpad operates all functions of the blower as well 

as the LED Mood light. A built in timer shuts the blower 

off 20 minutes after being activated. A purge cycle will 

automatically start the blower again for two (2) minutes, 

10 to 20 minutes after the blower has been shut off. This 

should be done in order to dry out the air channels. A daily 

purge can also be set to turn the blower on at the same time 

everyday. (See the 

Customized Settings 

section on page 12).

SIGNATURE EDITION AIRMASSEUR

®

REMOTE CONTROL fEATURES

In addition to the main control touchpad installed on the 

bath deck, a floating, waterproof Universal Remote Control 

is provided with all Signature Edition AirMasseur

®

 baths. 

This remote control provides the same control functions 

as the bath’s main control console, plus the bather may 

remotely operate a TV, DVD, VCR, CD, etc. Refer to the 

Instruction Manual provided with the remote control for 

detailed instructions. 

Summary of Contents for Forma AirMasseur AC635P

Page 1: ...llation will not be covered by warranty and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE 49 1000 113 Date 11 07 MUST BE MADE PRIOR TO INSTALLATION Inspect plumbing and bath surface for missing or damaged components Alert your dealer of any discrepancies To protect the unit from damage keep the unit in its carton until ready for installation EQUIPMENT ACCESS ...

Page 2: ...ed according to the instructions herein 5 Aninstallationtemplateisprovidedtolocatethefloordrain location sump area location remote blower tubing floor cutout location water inlet stub out location mounting holes and skirt center lines Tape the template to the sub floor in its desired location 6 Mark on the sub floor the sump area location the water inlet stub out location and the remote blower tub...

Page 3: ...netheproperfittothebath NOTE Itisrecommended that the Geberit drain and overflow model 150 176 be used If any other drain is used it may not conform to these instructions Drain Not Included This drain can be purchased from Figure 3 any authorized Jason International Inc dealer Position the bath in place and attach the drain and overflow to the floor drain P trap CAUTION Only dry fit the drain and ...

Page 4: ...OTE MOUNTING of air blower Do not remote mount the blower and control box more than 15 feet away from the air inlet of the bath Choose a location as close as possible to the bath to assure maximum efficiency 1 The installer is to determine the layout of the piping exact remote mount location and service access before beginning any work Use1 5 ABSorPVCplastictubing Locatethecontrolbox with the blow...

Page 5: ... Instructions section on page 11 or 12 for testing Faucetry connections should also be tested for leaks at this time 9 Remove the 2 x 4 boards and lower the bath into the skirt WARNING When you lower the bath into the skirt do not allow the hose sections to bind Align the drain and overflow with the corresponding bath holes and the bath brackets with the pre drilled holes in the skirt See Figure 8...

Page 6: ...edwiththeuseofawood edge trowel Paint or tar stains may need to be removed with a cleaner such as paint thinner turpentine or isopropyl alcohol rubbing alcohol Never allow the cleaner to soak against the surface for long periods of time Always rinse the surface immediately following the use of cleaners NOTE Follow the manufacturers instructions for safely using these or similar products If the sur...

Page 7: ... 6 ABOVE SUB FLOOR A licensed electrician must provide the dedicated electrical service protected by a GFCI The location of the GFCI must be at least five 5 feet away from the inside surface of the bath and accessible for regular testing Use copper conductors only DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit Interrupter GFCI In the unlikely occurrence...

Page 8: ...bath from bacteria viruses etc while leaving the plumbing lines clean and fresh The ozone system works automatically in conjunction with the blower motor TOUCHPAD FEATURES A main control touchpad mounted on the bath deck features an LCD readout which alternately indicates the water temperature 5 F and air bath time remaining The touchpad operates all functions of the blower as well as the LED Mood...

Page 9: ...th industry The blower control box must be properly connected for the bath to function correctly THE BLOWER CONTROL BOX The blower keypad LED light ozone sanitation unit and temperature sensor must be plugged into the proper receptacles for correct operation of the AirMasseur system See Figure 12 for connections A The junction box for the blower control box must be connected into a 240v 15 amp GFC...

Page 10: ...and the bath is completely drained the blower will start again for a 2 minute purge cycle that dries the air channel Note that the LCD display will read PURGE and begin to countdown the 10 or 20 minute pause before the purge cycle begins The readout will display PURGE ON during the purge cycle Any time during the pause before the purge cycle begins pressing and holding the Blower Speeds icon will ...

Page 11: ...by a slow flashing light Pressing the icon again will change the blower to Pulse mode This is indicated by a rapid light flash Pressing the icon a third time moves the blower back to Constant mode Blower Speeds Icon The Blower Speeds icon is used to increase or decrease the blower speed once the blower is on Press and hold the icon to decrease the blower speed until the desired inten sity is reach...

Page 12: ...his function has a 2 hour timer and remembers the last mode The LCD displays Light On or Light Off while the key is pressed for less than 2 seconds Light Cycle is displayed if pressed for more than 2 seconds OPTION ICON This key is reserved for future options CUSTOMIZED SETTINGS The12characterLCDdisplaycanbecustomizedbypressing the Blower and Blower Speeds icons simultaneously for 5 seconds while ...

Page 13: ...olution i e glass cleaner and a soft wet cloth or sponge Do not run the air system with foaming cleaners or soaps Rinse the bath thoroughly after cleaning SURFACE MAINTENANCE Areas with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jason dealer followed by an application of acrylic paste wax Buff t...

Page 14: ...fuses and replace if bad b Make sure plug is fully inserted into the outlet c Check and reconnect if necessary Blower shut off by itself or before time elapses a Blower motor overheated and thermal protection device deactivated motor possibly low voltage b GFCI tripped a Check that blower has sufficient ventillation and that the intake into the blower is not blocked Clear and allow the motor to co...

Page 15: ...ng Never use the therapy bath while under the influence of alcohol anticoagulants stimulants antihis tamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication should consult a physicia...