background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 1 of 15

 

 

 

 

Customer Service :  800.255.5766 

Jason International, Inc.

 

8328 MacArthur Drive

North Little Rock, AR 72118
www.jasoninternational.com

Copyright © 2010 Jason International.

“TO BE REMOVED FOR USE BY THE OCCUPANT.”

49-1011-203

Date    04/11

Owner’s Manual

rC/re630Ps & rC553Ps forma

 airMasseur

®

 Bath

InsTallaTIOn, OPeraTIOn, anD MaInTenanCe

Owner’s reCOrD

Dealer: 

Date Purchased: 

Date Installed: 

Installer: 

PlaCe serIal nuMBer CarD wITh 

PrODuCT COnfIguraTIOn In ThIs BOx

InsPeCTIOn

Inspect the unit prior to installation. In the event of a 

problem, DO NOT install the unit.

  

All components are factory assembled to the bath and the 
unit is water tested and inspected prior to leaving Jason 
International, Inc.

If the carton shows sign of damage, inspect the product 
before accepting and describe the problem on the Bill of 
Lading.

NOTe: Transportation and insurance from Jason’s 

factory are the buyer’s responsibility.

Damage sustained in transit is the responsibility of the 

carrier.

 If damage is discovered, 

If  the  carton  shows  sign  of  damage,  inspect 

the product before accepting and describe the 

problem on the Bill of lading.

the carrier must be immediately notified in writing with a 
request for a representative to inspect the unit. Failure of 
the carrier to respond should be reported to the seller and 
carrier. Always file a freight claim promptly.

The installer is responsible for insuring that the unit is 
free from defects or shipping damage. In the event of a 
problem, DO NOT install the unit. 
Jason International is not responsible for damage that 
might have been avoided by inspection or testing prior to 
installation.

Damage to the unit during installation will not be covered 
by warranty and is the responsibility of the installer. ALL 
WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE 
MUST BE MADE PRIOR TO INSTALLATION. Inspect 
plumbing and bath surface for missing or damaged 
components. Alert your dealer of any discrepancies.

To protect the unit from damage keep the bath in the 
carton until ready for installation.

Summary of Contents for forma AirMasseur RC553PS

Page 1: ...er s responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered If the carton shows sign of damage inspect the product before accepting and describe the pr...

Page 2: ...ions have been indicated on the template Choose the water inlet stub out position that is preferable for your installation 9 Remove the template and cut out the floor CAUTION The floor drain location...

Page 3: ...rain assembly free standing in the P trap 15 Align the drain with the center line on the template Refer to Figure 4 16 Permanently attach the drain tee to the P trap 17 Remove the template from the fl...

Page 4: ...oses may be purchased from Jason International Inc 20 Test all connections for leaks REMOTE MOUNTING of air blower The Jason AirMasseur system has been factory installed following E T L guidelines Dur...

Page 5: ...e 6 10 Remove blocks and place bath and skirt assembly in position Jason baths are designed to be supported at the base of the bath If the floor is smooth and level the bath s Level INSTALLATION INSTR...

Page 6: ...CODES MUST BE OBSERVED Where there are no local codes the National Electric Code NEC and Uniform Plumbing Code UPC shall be observed It is the responsibility of the installer owner to determine speci...

Page 7: ...ing a quality plastic polish like Novus Plastic Polish No 2 available from the Jason Dealer It is always preferable to protect the acrylic surface during installation to minimize cleanup and prevent s...

Page 8: ...ems the power cord for the Blower control box must be plugged into a 120v 15 amp GFCI dedicated circuit NOTE This diagram Figure 10 also applies to 50 Hz 240v controls and power supply systems Except...

Page 9: ...TRUCTIONS section of this owner s manual before its first use and periodically thereafter All Jason air baths are pre plumbed at the factory WARNING Before operating refer to the instructions pertaini...

Page 10: ...ture Remote Control In addition to the main control touchpad installed on the bath deck a floating waterproof Universal Remote Control is provided with all Signature Edition AirMasseur baths This remo...

Page 11: ...he Option icon is used to operate an optional LED light if installed Press the icon for less than two 2 seconds to turn the lights Off or On Hold the icon for more than two 2 seconds to change modes T...

Page 12: ...e correct control box See the CONTROL BOX CONNECTIONS section Remote Control The Signature Edition control system includes a waterproof floatingUniversalRemoteControl Itcontrolsallbathfunctions plus a...

Page 13: ...iquid detergent solution i e glass cleaner and a soft wet cloth or sponge Do not run the air system with foaming cleaners or soaps Rinse the bath thoroughly after cleaning SURFACE MAINTENANCE Areas wi...

Page 14: ...inserted into the outlet c Keypad is disconnected c Check and reconnect if necessary Blower shuts off by itself or before time elapses a Blower motor overheated and thermal protection device deactiva...

Page 15: ...the possibility of drowning Never use the therapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers...

Reviews: