FEATURES AND CONTROLS
Signature touchpad
A main control touchpad mounted on the bath deck features a
LCD readout which alternately indicates the water temperature
(+/- 5°F) and time remaining. The Signature Edition touchpad
allows the bather to control the blower, pump, LED mood light
and optional jetted neck pillow. A built in timer shuts the pump
and blower off 20 minutes after being activated.
Signature automatic Purge
Twenty (20) minutes after the control has shut off and the bath
is completely drained, the blower will start again for a two
minute purge cycle that dries the air channel. Note that the LCD
display will read “PURGE” and begin to countdown the 10 or
20 minute pause before the purge cycle begins. The readout
will display “PURGE ON” during the purge cycle. Any time
during the pause before the purge cycle begins, pressing and
holding the Blower Speeds icon will reduce the pause from 20
minutes to 10 minutes. During the two-minute purge, pressing
the “Blower On/Off” icon will stop the purge.
Signature daily Purge
The daily purge can be activated through the customized
settings of the Signature Edition touchpad. When activated,
the daily purge will start the blower for two-minutes at the
same time every day to dry the air channel. See ‘Operating the
Signature Edition AirMasseur Touchpad’ section for details on
activating this setting.
Signature remote Control
In addition to the main control touchpad installed on the
bath deck, a floating, waterproof Universal Remote Control
is provided with all Signature Edition AirMasseur
®
baths.
This remote control provides the same control functions
as the bath’s main control console, plus the bather may
remotely operate a TV, DVD, VCR, CD, etc. Refer to the
Instruction Manual provided with the remote control for
detailed instructions.
Blower
The blower generates warm air and pushes it through the
air jets. Blowers provided on Jason Air-Masseur® baths
are factory tested when assembled and again retested after
installation on the bath.
Filling and draining
Close the drain and fill the bath with water at least two (2)
inches (50mm) above the jets. The inlet temperature should
not exceed 40°C (104°F) as this could damage the acrylic
surface. When bath is in use, turn the unit Off before draining
the water. The bath unit and its plumbing are designed to drain
after each use whether used as a hydrotherapy bath, soaking
bath, or just taking a shower.
NOTe:
If the unit fails to operate, check the breaker panel to
insure that the circuit breaker is on. Check the GFCI by testing
and resetting it. Also check the water level in the bath; it must
be above the water level sensor located on the sidewall of the
bath for the pump to operate. If the unit still fails to operate,
refer to the Trouble Shooting Guide section of this owner’s
manual. If the unit still fails to operate and is out of warranty,
contact an authorized service technician for repair. If the
unit is within the warranty period, contact JASON Technical
Services at 800-255-5766. DO NOT ATTEMPT TO RESOLVE
THE PROBLEM.