background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 12 of 15

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2010 Jason International.

OPERATING INSTRUCTIONS, FEATURES, AND CONTROLS (cont.)

SIGNATURE EDITION AIRMASSEUR

®

 

TOUChPAD

The Jason Signature Edition Digital AirMasseur

®

 touchpad is used to access all of the functions of the control box used in 

a Jason Signature Edition AirMasseur

®

 bath. 

Customized Settings

The 12 character LCD display can be customized by pressing 
the Blower and Blower Speeds icons simultaneously for five 
(5) seconds, while the system is Off. 

note: 

The Blower Speeds 

icon will not be illuminated during this process. Use the above 
figure to locate the icon. A menu (see below) will be displayed 
to choose the following: Purge 24, (starts the blower every 
24 hours for two (2) minutes at the time the purge was set); 
Product Test Diagnostics (see below); Temperature (Fahrenheit 
or Celsius); and Language (English or Spanish).

Menu Instructions

Use  the  Blower  icon  to  scroll  through  the  different  menu 
items.  Use  the  Blower  Speeds  icon  to  change  an  option. 
For example, press and release the Blower icon to change 
from Purge 24 to Product Test; press and release again to 
arrive at the Temperature option. Then press and release the 
Blower Speeds icon to change the temperature display from 
F (Fahrenheit) to C (Celsius).

Product Test Diagnostics

After selecting the Product Test option from the menu, the unit 
will perform a series of tests to confirm correct installation of 
components. The test will begin by displaying the configuration 
number, followed by the software revision number. Next, the 
display will test the Temperature and Low Water Level sensor 
(ITW-209). Next, each of the six (6) icons will begin to light. 
Press the illuminated icon to proceed to the next icon. After the 
icon test, the blower will start for two (2) seconds on the High 
setting. Lastly, the LED Light unit will be tested. If you receive 
an error on any of the tests, confirm proper installation of the 
component to the correct control box.  (See the 

CONTROL 

BOX CONNeCTIONS

 section).

Remote Control

The Signature Edition control system includes a waterproof 
floating Universal Remote Control. It controls all bath functions 
plus a TV, DVD, CD, etc. which can be heard through the 
optional Sound Immersion Transducers (optional).

Blower On/Off, Modes

Blower Speeds

LED Light

IR for Remote

OPERATING INSTRUCTIONS

Blower On/Off and Modes Icon

To control the operation of the blower, simply press and release 
to change the setting to Constant, Wave, Pulse or Off. A 20 
minute  decreasing  timer  will  be  initiated  when  the  blower 
motor starts. Press and hold the Blower icon to cycle though 
blower modes. The Blower icon should remain lit as long as 
the bath is connected to a power supply. The LCD will display 
“Const Air” and blower speed, “Wave Air” and blower speed, 
or  “Pulse  Air”  and  blower  speed,  while  the  key  is  pressed. 
The time remaining on the purge cycle is displayed after the 
bath has drained. “Purge Stop” is displayed while the key is 
pressed during the purge cycle. This action will terminate the 
purge cycle. The mode settings will be remembered on the 
next startup.

Blower Speeds Icon

Hold the key in Constant mode to go from High to Low then 
release and hold again to go from Low to High. Hold the key in 
Wave and Pulse mode to go from High to Medium and Medium 
to High. The system remembers the last speed setting on the 
next startup. The Blower Speeds icon will light up when the 
blower is running. The LED displays the blower speed from 
“10” (Low) or “55”(Med) to “99” (High) while the key is pressed. 
You can reduce the auto purge idle time from 20 minutes to 
10 minutes, by pressing and holding the key for more than 
5-seconds during the purge idle period.

LED Light Icon

Hold the icon for less than two (2) seconds to turn the lights Off 
or On. Hold the icon for more than two (2) seconds to change 
modes. The Light icon should remain lit as long as the bath 
is connected to a power supply. This function has a two (2) 
hour timer and remembers the last mode. The LCD displays 
“Light On” or “Light Off” while the icon is pressed for less than 
two (2) seconds. “Light Cycle” is displayed if pressed for more 
than two (2) seconds. 

Summary of Contents for forma AirMasseur RC553PS

Page 1: ...er s responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered If the carton shows sign of damage inspect the product before accepting and describe the pr...

Page 2: ...ions have been indicated on the template Choose the water inlet stub out position that is preferable for your installation 9 Remove the template and cut out the floor CAUTION The floor drain location...

Page 3: ...rain assembly free standing in the P trap 15 Align the drain with the center line on the template Refer to Figure 4 16 Permanently attach the drain tee to the P trap 17 Remove the template from the fl...

Page 4: ...oses may be purchased from Jason International Inc 20 Test all connections for leaks REMOTE MOUNTING of air blower The Jason AirMasseur system has been factory installed following E T L guidelines Dur...

Page 5: ...e 6 10 Remove blocks and place bath and skirt assembly in position Jason baths are designed to be supported at the base of the bath If the floor is smooth and level the bath s Level INSTALLATION INSTR...

Page 6: ...CODES MUST BE OBSERVED Where there are no local codes the National Electric Code NEC and Uniform Plumbing Code UPC shall be observed It is the responsibility of the installer owner to determine speci...

Page 7: ...ing a quality plastic polish like Novus Plastic Polish No 2 available from the Jason Dealer It is always preferable to protect the acrylic surface during installation to minimize cleanup and prevent s...

Page 8: ...ems the power cord for the Blower control box must be plugged into a 120v 15 amp GFCI dedicated circuit NOTE This diagram Figure 10 also applies to 50 Hz 240v controls and power supply systems Except...

Page 9: ...TRUCTIONS section of this owner s manual before its first use and periodically thereafter All Jason air baths are pre plumbed at the factory WARNING Before operating refer to the instructions pertaini...

Page 10: ...ture Remote Control In addition to the main control touchpad installed on the bath deck a floating waterproof Universal Remote Control is provided with all Signature Edition AirMasseur baths This remo...

Page 11: ...he Option icon is used to operate an optional LED light if installed Press the icon for less than two 2 seconds to turn the lights Off or On Hold the icon for more than two 2 seconds to change modes T...

Page 12: ...e correct control box See the CONTROL BOX CONNECTIONS section Remote Control The Signature Edition control system includes a waterproof floatingUniversalRemoteControl Itcontrolsallbathfunctions plus a...

Page 13: ...iquid detergent solution i e glass cleaner and a soft wet cloth or sponge Do not run the air system with foaming cleaners or soaps Rinse the bath thoroughly after cleaning SURFACE MAINTENANCE Areas wi...

Page 14: ...inserted into the outlet c Keypad is disconnected c Check and reconnect if necessary Blower shuts off by itself or before time elapses a Blower motor overheated and thermal protection device deactiva...

Page 15: ...the possibility of drowning Never use the therapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers...