INSTALLATION

Remove  the  product  from  its  packaging.   

read  the  entire 

instructions prior to installing this product. 

 

see user MaInTenanCe InsTruCTIOns section of this owner’s 

manual  for  humidity  and  mold  prevention  suggestions  prior  to 

Installation. 

1. 

remove the packing board from the skirt 

by placing the bath 

and  skirt  assembly  upside  down  and  remove  the  four 
press-in fasteners.

   see figure1.

CauTIOn:  Place bath deck on a surface that will not scratch the 

acrylic surface of the bath.

2. 

Disassemble the bath from its skirt 

by removing the four nuts 

and washers located at the bottom of the bath with a 1/2” 
open ended wrench.  Lift the skirt out of the bath.  Place 
the skirt and the bath in an upright position next to each 
other.

  

 See

 figure 1. 

 

3. 

set aside the template, tubing with 2 clamps,

 

and locating stud 

kit,

 these will be used later.  

4. 

Blower Carton.

  Remove the blower with stand, check valve, 

and  remote  control  (when  supplied)  from  the  separate 
blower carton.  

5. 

Key Pad and sani Design Cleaning system Kit

.  Set aside to 

be installed later.

6.

 

Cardboard bath-well protector.

  Each bath is provided with a 

cardboard bath-well protector that should be kept in the 
unit throughout the bathroom construction process.  

 

nOTe: 

 Overflow drains, fill spouts, and valves must 

be installed according to the instructions herein.

7. 

Installation template.  

An installation template is provided to 

locate the floor drain position, sump area position, remote 
blower-tubing  floor  cutout  position,  water  inlet  stub-out 
position, and skirt center lines.  Tape the template to the 
sub-floor in the desired location.  

8. 

Mark  on  the  sub-floor

  the  sump  area  position,  the  water 

inlet stub-out position, and the remote blower-tubing floor 
cut out position.  One remote blower tubing, floor cutout 
position and three (3) water inlet stub-out positions have 
been indicated on the template.  Choose the water inlet 
stub-out position that is preferable for your installation.  

9. 

remove the template and cut out the floor.

 

CauTIOn:

  

The floor drain location must be installed according 

to the template.  This location is critical to the proper installation 

of this product.  

 

nOTe:  

You must keep the template, it will be needed 

during the next step of the installation process. See 

figure 2

.

nOTe:  

The skirt is designed to accommodate both an 

end drain (Re630PS) and a center drain (RC630PS) 

model. Refer to 

figure  2

 to determine which cut-outs 

are designed for use with your particular model.

10 

after the finished floor is installed,

  position  the  installation 

template on the finished floor.  Place the template to line 
up  with  the  existing  floor  drain  location  and  orient  the 
template to the desired position.  

nOTe:

  The sump area location cutout, remote blower 

tubing floor location cutout, and water inlet  stub-out 

location  must line up with the template.  

nOTe:

 The keypad and Sani-Design

tm

 cleaning system 

have not been installed.  See the forma

TM

 Collection 

field Installation Instructions

 for the AirMasseur

®

 keypad 

and Sani-Design

TM

 cleaning system.

11.

Tape  the  template  to  the  finished  floor

  using  care  to  align 

both center lines and assure that the template is laying 
flat on the floor.  

12.

Transfer the center lines of the template to the finished floor. 

figure  1

INSTALLATION   INSTRUCTIONS

TABLE 1 - SPECIFICATIONS

Model

Overall 

Dimension 

l x w x h (in.)

l x w x h (cm)

Operating

Capacity

gal 

liters

Blower

hP

Min. size

access

w x h (in.)

w x h (cm)

floor

loading

lbs/ft

2

Kg/M

2

RE630PS

72 x 36 x 22

53

1

36 x 17

54.6 lbs

183 x 91 x 56

200

91 x 43

267 kg

RC630PS

72 x 36 x 22

50

1

36 x 17

53 lbs

183 x 91 x 56

189

91 x 43

259 kg

RC553PS

36 x 66 x 22

45

1

36 x 17

53.8 lbs

91 x 168 x 56

170

91 x 43

249

Remote Control

(When Supplied)

Control Box

(Signature Edition)

Blower with Stand

and Check Valve

Bath-Well Protector

Template

Tubing with

Clamps

Packing Board

Skirt

Bath

Keypad

Locating

Studs Kit

Sani Design

Cleaning 

System Kit

5/16" Nut and

Washer (x4)

Press-in

Fasteners (x4)

Stabilizing Nut

and Washer (x4)

Summary of Contents for forma AirMasseur RC553PS

Page 1: ...er s responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered If the carton shows sign of damage inspect the product before accepting and describe the pr...

Page 2: ...ions have been indicated on the template Choose the water inlet stub out position that is preferable for your installation 9 Remove the template and cut out the floor CAUTION The floor drain location...

Page 3: ...rain assembly free standing in the P trap 15 Align the drain with the center line on the template Refer to Figure 4 16 Permanently attach the drain tee to the P trap 17 Remove the template from the fl...

Page 4: ...oses may be purchased from Jason International Inc 20 Test all connections for leaks REMOTE MOUNTING of air blower The Jason AirMasseur system has been factory installed following E T L guidelines Dur...

Page 5: ...e 6 10 Remove blocks and place bath and skirt assembly in position Jason baths are designed to be supported at the base of the bath If the floor is smooth and level the bath s Level INSTALLATION INSTR...

Page 6: ...CODES MUST BE OBSERVED Where there are no local codes the National Electric Code NEC and Uniform Plumbing Code UPC shall be observed It is the responsibility of the installer owner to determine speci...

Page 7: ...ing a quality plastic polish like Novus Plastic Polish No 2 available from the Jason Dealer It is always preferable to protect the acrylic surface during installation to minimize cleanup and prevent s...

Page 8: ...ems the power cord for the Blower control box must be plugged into a 120v 15 amp GFCI dedicated circuit NOTE This diagram Figure 10 also applies to 50 Hz 240v controls and power supply systems Except...

Page 9: ...TRUCTIONS section of this owner s manual before its first use and periodically thereafter All Jason air baths are pre plumbed at the factory WARNING Before operating refer to the instructions pertaini...

Page 10: ...ture Remote Control In addition to the main control touchpad installed on the bath deck a floating waterproof Universal Remote Control is provided with all Signature Edition AirMasseur baths This remo...

Page 11: ...he Option icon is used to operate an optional LED light if installed Press the icon for less than two 2 seconds to turn the lights Off or On Hold the icon for more than two 2 seconds to change modes T...

Page 12: ...e correct control box See the CONTROL BOX CONNECTIONS section Remote Control The Signature Edition control system includes a waterproof floatingUniversalRemoteControl Itcontrolsallbathfunctions plus a...

Page 13: ...iquid detergent solution i e glass cleaner and a soft wet cloth or sponge Do not run the air system with foaming cleaners or soaps Rinse the bath thoroughly after cleaning SURFACE MAINTENANCE Areas wi...

Page 14: ...inserted into the outlet c Keypad is disconnected c Check and reconnect if necessary Blower shuts off by itself or before time elapses a Blower motor overheated and thermal protection device deactiva...

Page 15: ...the possibility of drowning Never use the therapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers...