CauTIOn:

 

Use a marker that can be removed from the 

finished floor after installation.  

13.

Position the skirt 

(only) and align it with the centerlines on 

the finished floor.  Use the four existing 3/8” holes located 
in the bottom four corners of the skirt

 

to mark where to 

drill the pilot holes for the four locating studs.  If installing 
on a wooden floor, 1/4” [6mm] holes are required, and a 
5/16” nut to install the locating studs into the wooden floor.  
When installing on a cement slab, 3/8” [9.5mm] holes are 
required.  

see figure 3.

  After marking the hole locations, 

remove the skirt and set aside.

14.

Dry fit the drain and overflow to the bath.

  

a.  Dry fit the drain and overflow to the bath.  Use the 

instructions  included  with  the  drain  and  overflow  to 
determine proper fit.  It is recommended that 

flex

 PVC 

pipe be used between the overflow and drain. This will 
assure there is enough clearance between the bath 
shell and the skirt for the drain.

b.  Position bath in place and attach the drain and overflow 

to  the  floor  drain  “P”  trap.   

CauTIOn:

 

Only  dry  fit 

the drain and overflow tee to the “P” trap at this 

time.  

figure  2

figure  4

c.  Disconnect the drain and overflow from the bath and 

leave  the  drain  assembly  free  standing  in  the  “P” 
trap.  

15.

align the drain with the center line on the template. 

Refer to  

figure 4.

  

16. 

Permanently attach the drain tee to the “P” trap.  

17. 

remove the template from the floor.

18.

Install the skirt locating studs

 into the four positions in the 

floor.  See 

figure 5

.  

19.

attach faucet accessories 

to the bath (if applicable).  

 

CauTIOn:

 

There is not enough room to mount a deck 

mounted diverter valve on the deck of the bath.  

  If a hand-held shower is desired consider a floor mounted 

faucet or a faucet with an above deck diverter.  

If  a  floor  mounted  faucet  is  desired,  be  sure  to  install 
the faucet to allow for sufficient overhang into the well 
of the bath.  This will ensure an unobstructed water flow 
out of the faucet when filling the bath.  Follow the faucet 
manufacturers installation instructions.

20. 

flex plumbing.  

Attach stainless steel flex plumbing to the 

figure  5

INSTALLATION INSTRUCTIONS (cont.)

1 38 "

1 38 "

Cutout C

Cutout A

Cutout B

Cutout B

Cutout A

Cutout B

Floor Drain

Location

Bath Drain

(Ref Only)

Bath Drain

(Ref Only)

Sump Area

Location

(for 

RE630PS

 Only)

Sump Area

Location

(for 

RC630PS

 Only)

Water Inlet

Stub-Out

Location

Water Inlet

Stub-Out

Location

 

Floor Drain

Location

Remote Blower

Tubing Floor

Cutout Location

Skirt

Template

Locating Stud

Pilotholes (x4)

3/8" Holes (x4)

8"

6"

Locating Stud Bolts (x4)

Remote Blower

Tubing Floor

Location

Water Inlet

Stub-Out

Location

Stub-Out (x2)

Sump Area

Location

Drain

Overflow

(PVC Flex Pipe)

Overflow

Floor

figure  3

Summary of Contents for forma AirMasseur RC553PS

Page 1: ...er s responsibility Damage sustained in transit is the responsibility of the carrier If damage is discovered If the carton shows sign of damage inspect the product before accepting and describe the pr...

Page 2: ...ions have been indicated on the template Choose the water inlet stub out position that is preferable for your installation 9 Remove the template and cut out the floor CAUTION The floor drain location...

Page 3: ...rain assembly free standing in the P trap 15 Align the drain with the center line on the template Refer to Figure 4 16 Permanently attach the drain tee to the P trap 17 Remove the template from the fl...

Page 4: ...oses may be purchased from Jason International Inc 20 Test all connections for leaks REMOTE MOUNTING of air blower The Jason AirMasseur system has been factory installed following E T L guidelines Dur...

Page 5: ...e 6 10 Remove blocks and place bath and skirt assembly in position Jason baths are designed to be supported at the base of the bath If the floor is smooth and level the bath s Level INSTALLATION INSTR...

Page 6: ...CODES MUST BE OBSERVED Where there are no local codes the National Electric Code NEC and Uniform Plumbing Code UPC shall be observed It is the responsibility of the installer owner to determine speci...

Page 7: ...ing a quality plastic polish like Novus Plastic Polish No 2 available from the Jason Dealer It is always preferable to protect the acrylic surface during installation to minimize cleanup and prevent s...

Page 8: ...ems the power cord for the Blower control box must be plugged into a 120v 15 amp GFCI dedicated circuit NOTE This diagram Figure 10 also applies to 50 Hz 240v controls and power supply systems Except...

Page 9: ...TRUCTIONS section of this owner s manual before its first use and periodically thereafter All Jason air baths are pre plumbed at the factory WARNING Before operating refer to the instructions pertaini...

Page 10: ...ture Remote Control In addition to the main control touchpad installed on the bath deck a floating waterproof Universal Remote Control is provided with all Signature Edition AirMasseur baths This remo...

Page 11: ...he Option icon is used to operate an optional LED light if installed Press the icon for less than two 2 seconds to turn the lights Off or On Hold the icon for more than two 2 seconds to change modes T...

Page 12: ...e correct control box See the CONTROL BOX CONNECTIONS section Remote Control The Signature Edition control system includes a waterproof floatingUniversalRemoteControl Itcontrolsallbathfunctions plus a...

Page 13: ...iquid detergent solution i e glass cleaner and a soft wet cloth or sponge Do not run the air system with foaming cleaners or soaps Rinse the bath thoroughly after cleaning SURFACE MAINTENANCE Areas wi...

Page 14: ...inserted into the outlet c Keypad is disconnected c Check and reconnect if necessary Blower shuts off by itself or before time elapses a Blower motor overheated and thermal protection device deactiva...

Page 15: ...the possibility of drowning Never use the therapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers...