background image

Jason International, Inc.  •  

 

501.771.4477  

    

Page 17 of 24

 

   

Customer Service :  800.255.5766 

Copyright © 2013 Jason International.

Figure 9

SIGNATURE EDITION AIRMASSEUR

®

 TOUCHPAD

The Jason Signature Edition Digital AirMasseur

®

 touchpad is used to access all  

of the functions of the control box used in a Jason Signature Edition AirMasseur

®

 bath. 

Customized Settings

The 12 character LCD display can be customized 
by pressing the Blower and Blower Speeds icons 
simultaneously for five (5) seconds, while the system is 
Off. 

note: 

The Blower Speeds icon will not be illuminated 

during this process. Use the above figure to locate the 
icon. A menu (see below) will be displayed to choose the 
following: Purge 24, (starts the blower every 24 hours for 
two (2) minutes at the time the purge was set); Product 
Test Diagnostics (see below); Temperature (Fahrenheit or 
Celsius); and Language (English or Spanish).

Menu Instructions

Use the Blower icon to scroll through the different menu 
items. Use the Blower Speeds icon to change an option. 
For example, press and release the Blower icon to change 
from Purge 24 to Product Test; press and release again to 
arrive at the Temperature option. Then press and release 
the Blower Speeds icon to change the temperature display 
from F (Fahrenheit) to C (Celsius).

Product Test Diagnostics

After selecting the Product Test option from the menu, 
the unit will perform a series of tests to confirm correct 
installation of components. The test will begin by displaying 
the configuration number, followed by the software revision 
number. Next, the display will test the Temperature and 
Low Water Level sensor (ITW-209). Next, each of the six 
(6) icons will begin to light. Press the illuminated icon to 
proceed to the next icon. After the icon test, the blower will 
start for two (2) seconds on the High setting. Lastly, the 
LED Light unit will be tested. If you receive an error on any 
of the tests, confirm proper installation of the component 
to the correct control box.  (See the CONTROL BOX 
CONNECTIONS
 section).

Remote Control

The Signature Edition control system includes a waterproof 
floating Universal Remote Control. It controls all bath 
functions plus a TV, DVD, CD, etc. which can be heard 
through the optional Sound Immersion Transducers 
(optional).

Blower On/Off, Modes

Blower Speeds

LED Light

IR for Remote

OPERATING INSTRUCTIONS, FEATURES, AND CONTROLS (cont.)

OPERATING INSTRUCTIONS

Blower On/Off and Modes Icon

To control the operation of the blower, simply press and 
release to change the setting to Constant, Wave, Pulse 
or Off. A 20 minute decreasing timer will be initiated when 
the blower motor starts. Press and hold the Blower icon to 
cycle though blower modes. The Blower icon should remain 
lit as long as the bath is connected to a power supply. The 
LCD will display “Const Air” and blower speed, “Wave Air” 
and blower speed, or “Pulse Air” and blower speed, while 
the key is pressed. The time remaining on the purge cycle 
is displayed after the bath has drained. “Purge Stop” is 
displayed while the key is pressed during the purge cycle. 
This action will terminate the purge cycle. The mode settings 
will be remembered on the next startup.

Blower Speeds Icon

Hold the key in Constant mode to go from High to Low then 
release and hold again to go from Low to High. Hold the 
key in Wave and Pulse mode to go from High to Medium 
and Medium to High. The system remembers the last speed 
setting on the next startup. The Blower Speeds icon will light 
up when the blower is running. The LED displays the blower 
speed from “10” (Low) or “55"(Med) to “99” (High) while the 
key is pressed. You can reduce the auto purge idle time 
from 20 minutes to 10 minutes, by pressing and holding the 
key for more than 5-seconds during the purge idle period.

LED Light Icon

Hold the icon for less than two (2) seconds to turn the lights 
Off or On. Hold the icon for more than two (2) seconds to 
change modes. The Light icon should remain lit as long as 
the bath is connected to a power supply. This function has a 
two (2) hour timer and remembers the last mode. The LCD 
displays “Light On” or “Light Off” while the icon is pressed 
for less than two (2) seconds. “Light Cycle” is displayed if 
pressed for more than two (2) seconds. 

Summary of Contents for forma AirMasseur RE630PS

Page 1: ...responsible for insuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit If the carton shows sign of damage inspect the product before accepting...

Page 2: ...e AEC carton aside to be installed later 4 Cardboard bath well protector Each bath is provided with a cardboard bath well protector that should be kept in the unit throughout the bathroom construction...

Page 3: ...four existing 3 8 holes located in the bottom four corners of the skirt to mark where to drill the pilot holes for the four locating studs If installing on a wooden floor 1 4 6mm holes are required a...

Page 4: ...IR BLOWER section of this manual before proceeding to the next step 20 Reattach the skirt to the bath by positioning the skirt on the bath and fastening the 5 16 nut and washers to the 5 16 leveling b...

Page 5: ...ted by any control device Likewise the electrical service from the GFCI to the bath control should be direct and not interrupted by a switch Never use a switch in conjunction with a control device Thi...

Page 6: ...nature Edition AirMasseur Control Box The blower junction box must be connected into a dedicated 240v 15A 50 or 60Hz GFCI protected circuit See Figure 9a Control Box Light Cable Check Valve Blower Blo...

Page 7: ...routed away from the equipment or other heat producing compo nents of the unit Figure 10 Standard Premier Edition MicroSilk m MICROSILK Control Box Dedicated 120V 50 or 60 Hz GFCI Protected Service G...

Page 8: ...e blower s check valve Use screws to attach the pipe to the check valve and route the hose to the remote blower tubing floor cutout location CAUTION Do NOT use ABS or PVC glue near the blower it could...

Page 9: ...NSTALLATION INSTRUCTIONS cont ACRYLIC EQUIPMENT CABINET INSTALLATION The Jason Acrylic Equipment Cabinet AEC can be used to house the bath equipment that cannot be remote mounted away from the bath Th...

Page 10: ...the appropriate barb using the clamp provided Assure the line will allow proper drainage to the bath fitting The hose must have a continuous drop from the barb to the fitting See Figure 14c Figure 14...

Page 11: ...olish No 2 available from the Jason Dealer It is always preferable to protect the acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the...

Page 12: ...pt that the Blower junction box must be connected into one dedicated 240v 15 Amp GFCI circuit PREMIER EDITION AIRMASSEUR Jason s Premier Edition AirMasseur system incorporates all the features of the...

Page 13: ...ord to ozone unit Figure 17 NOTE This diagram Figure 17 also applies to 50 Hz 240v controls and power supply systems MICROSILK CONTROL BOX CONNECTIONS STANDARD EDITION MICROSILK Jason s Standard Editi...

Page 14: ...r LED light G Ozone Unit pre wired to control box PREMIER EDITION MICROSILK Jason s Premier Edition MicroSilk system incorporates all the features of the Standard Edition system and includes the benef...

Page 15: ...er is powered a digital control with LCD display window low water and temperature sensors and a 20 minute timer Signature Touchpad A main control touchpad mounted on the bath deck features a LCD reado...

Page 16: ...LED light if installed Press the icon for less than two 2 seconds to turn the lights Off or On Hold the icon for more than two 2 seconds to change modes This function has a two 2 hour timer and remem...

Page 17: ...TIONS section Remote Control The Signature Edition control system includes a waterproof floating Universal Remote Control It controls all bath functions plus a TV DVD CD etc which can be heard through...

Page 18: ...ol touchpad installed on the bath deck a floating waterproof Universal Remote Control is provided with all Signature Edition MicroSilk baths This remote control provides the same control functions as...

Page 19: ...icon is used to activate the MicroSilk unit and the 20 minute timer Press the icon the first time to start the MicroSilk unit Press the icon again to shut off the MicroSilk unit LED Light Icon The LED...

Page 20: ...ote Use the above figure to locate the icons A menu will be displayed to choose the following Product Test Diagnostics Temperature F or C and Language English or Spanish Menu Instructions Use the top...

Page 21: ...ass cleaner and a soft wet cloth or sponge Do not run the hydrotherapy system with foaming cleaners or soaps Rinse the bath thoroughly after cleaning USER MAINTENANCE INSTRUCTIONS SURFACE MAINTENANCE...

Page 22: ...overheated and thermal protection device deactivated motor possibly low voltage b GFCI tripped a Check that blower has sufficient ventilation and that the intake into the blower is not blocked Clear...

Page 23: ...ice deactivated motor Possibly low voltage b GFCI tripped c Water level fell below recommended level a Make sure motor air cooling vents are not blocked clear and allow motor to cool down Check servic...

Page 24: ...trictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physici...