background image

Jason International, Inc.  •  

 

501.771.4477  

    

Page 18 of 24

 

   

Customer Service :  800.255.5766 

Copyright © 2013 Jason International.

MICROSILK

®

 OPERATION

STANDARD AND PREMIER EDITION MICROSILK

®

 

The Jason Standard Edition MicroSilk

®

 bath includes a 

Microbubble generator unit, an electronic control, and a 
20-minute timer.

The Jason Premier Edition MicroSilk

®

 bath provides all the 

features of the Standard Edition with the included benefits 
of an LED Chromatherapy Mood Light, and an Ozone 
Sanitation system.

Standard/Premier Touchpad 
One main control touchpad mounted on the bath deck 
features several icons used by the bather to control the 
MicroSilk

®

 unit and LED mood light. A built-in timer shuts 

the pump off 20 minutes after being activated.

SIGNATURE EDITION MICROSILK

®

 

The Jason Signature Edition MicroSilk bath includes a 
Microbubble generator unit; Chromatherapy mood light, 
Automatic Ozone System that will be operated any time 
the pump is powered; a digital control with LCD-display 
window; low water and temperature sensors;  
and a 20-minute timer.

Signature Touchpad 
A main control touchpad mounted on the bath deck fea-
tures an LCD readout which alternately indicates the water 
temperature (+/- 5° F) and time remaining. The Signature 
Edition touchpad allows the bather to control the MicroSilk

®

 

pump and LED mood light. A built-in timer shuts off the 
pump 20 minutes after being activated.

OPERATING INSTRUCTIONS, FEATURES, AND CONTROLS (cont.)

Signature Remote Control 
In addition to the main control touchpad installed on the 
bath deck, a floating, waterproof Universal Remote Control 
is provided with all Signature Edition MicroSilk

®

 baths. This 

remote control provides the same control functions as the 
bath’s main control console, plus the bather may remotely 
operate a TV, DVD, VCR, CD, etc. Refer to the Instruc-
tion Manual provided with the remote control for detailed 
instructions.

Port 
A strategically placed MicroSilk

®

 port is provided for com-

plete enjoyment of your bath.

MicroSilk

®

 Unit 

The MicroSilk

®

 unit generates oxygen-rich microbubbles 

that fill the bath. MicroSilk

®

 units provided on Jason baths 

are factory tested when assembled and again retested 
after installation on the bath.

Filling and Draining 
Close the drain and fill the bath with water at least two (2) 
inches (50mm) above the jet. The inlet temperature should 
not exceed 104°F (40°C). When bath is in use, turn the unit 
Off before draining the water. The bath unit and its plumb-
ing are designed to drain after each use whether used as a 
hydrotherapy bath, soaking bath, or just taking a shower.

NOTE: If the unit fails to operate, check the breaker 
panel to ensure that the circuit breaker is on. Check 
the GFCI by testing and resetting it. Also check the 
water level in the bath; it must be above the water 
level sensor located on the sidewall of the bath for the 
pump to operate. If the unit still fails to operate, refer 
to the Trouble Shooting Guide section of this manual. 
If the unit still fails to operate and is out of warranty, 
contact an authorized service technician for repair.  
If the unit is within the warranty period,  
contact JASON Technical Services at 800-255-5766. 
DO NOT ATTEMPT TO RESOLVE THE PROBLEM.

Summary of Contents for forma AirMasseur RE630PS

Page 1: ...responsible for insuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit If the carton shows sign of damage inspect the product before accepting...

Page 2: ...e AEC carton aside to be installed later 4 Cardboard bath well protector Each bath is provided with a cardboard bath well protector that should be kept in the unit throughout the bathroom construction...

Page 3: ...four existing 3 8 holes located in the bottom four corners of the skirt to mark where to drill the pilot holes for the four locating studs If installing on a wooden floor 1 4 6mm holes are required a...

Page 4: ...IR BLOWER section of this manual before proceeding to the next step 20 Reattach the skirt to the bath by positioning the skirt on the bath and fastening the 5 16 nut and washers to the 5 16 leveling b...

Page 5: ...ted by any control device Likewise the electrical service from the GFCI to the bath control should be direct and not interrupted by a switch Never use a switch in conjunction with a control device Thi...

Page 6: ...nature Edition AirMasseur Control Box The blower junction box must be connected into a dedicated 240v 15A 50 or 60Hz GFCI protected circuit See Figure 9a Control Box Light Cable Check Valve Blower Blo...

Page 7: ...routed away from the equipment or other heat producing compo nents of the unit Figure 10 Standard Premier Edition MicroSilk m MICROSILK Control Box Dedicated 120V 50 or 60 Hz GFCI Protected Service G...

Page 8: ...e blower s check valve Use screws to attach the pipe to the check valve and route the hose to the remote blower tubing floor cutout location CAUTION Do NOT use ABS or PVC glue near the blower it could...

Page 9: ...NSTALLATION INSTRUCTIONS cont ACRYLIC EQUIPMENT CABINET INSTALLATION The Jason Acrylic Equipment Cabinet AEC can be used to house the bath equipment that cannot be remote mounted away from the bath Th...

Page 10: ...the appropriate barb using the clamp provided Assure the line will allow proper drainage to the bath fitting The hose must have a continuous drop from the barb to the fitting See Figure 14c Figure 14...

Page 11: ...olish No 2 available from the Jason Dealer It is always preferable to protect the acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the...

Page 12: ...pt that the Blower junction box must be connected into one dedicated 240v 15 Amp GFCI circuit PREMIER EDITION AIRMASSEUR Jason s Premier Edition AirMasseur system incorporates all the features of the...

Page 13: ...ord to ozone unit Figure 17 NOTE This diagram Figure 17 also applies to 50 Hz 240v controls and power supply systems MICROSILK CONTROL BOX CONNECTIONS STANDARD EDITION MICROSILK Jason s Standard Editi...

Page 14: ...r LED light G Ozone Unit pre wired to control box PREMIER EDITION MICROSILK Jason s Premier Edition MicroSilk system incorporates all the features of the Standard Edition system and includes the benef...

Page 15: ...er is powered a digital control with LCD display window low water and temperature sensors and a 20 minute timer Signature Touchpad A main control touchpad mounted on the bath deck features a LCD reado...

Page 16: ...LED light if installed Press the icon for less than two 2 seconds to turn the lights Off or On Hold the icon for more than two 2 seconds to change modes This function has a two 2 hour timer and remem...

Page 17: ...TIONS section Remote Control The Signature Edition control system includes a waterproof floating Universal Remote Control It controls all bath functions plus a TV DVD CD etc which can be heard through...

Page 18: ...ol touchpad installed on the bath deck a floating waterproof Universal Remote Control is provided with all Signature Edition MicroSilk baths This remote control provides the same control functions as...

Page 19: ...icon is used to activate the MicroSilk unit and the 20 minute timer Press the icon the first time to start the MicroSilk unit Press the icon again to shut off the MicroSilk unit LED Light Icon The LED...

Page 20: ...ote Use the above figure to locate the icons A menu will be displayed to choose the following Product Test Diagnostics Temperature F or C and Language English or Spanish Menu Instructions Use the top...

Page 21: ...ass cleaner and a soft wet cloth or sponge Do not run the hydrotherapy system with foaming cleaners or soaps Rinse the bath thoroughly after cleaning USER MAINTENANCE INSTRUCTIONS SURFACE MAINTENANCE...

Page 22: ...overheated and thermal protection device deactivated motor possibly low voltage b GFCI tripped a Check that blower has sufficient ventilation and that the intake into the blower is not blocked Clear...

Page 23: ...ice deactivated motor Possibly low voltage b GFCI tripped c Water level fell below recommended level a Make sure motor air cooling vents are not blocked clear and allow motor to cool down Check servic...

Page 24: ...trictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physici...

Reviews: