background image

Jason International, Inc.  •  

 

501.771.4477  

    

Page 20 of 24

 

   

Customer Service :  800.255.5766 

Copyright © 2013 Jason International.

The Jason Signature Edition MicroSilk

®

 digital touchpad is 

used to access all the functions of the MicroSilk

®

 bath. 

OPERATING INSTRUCTIONS

MicroSilk

®

 On/Off  Icon

To control the operation of the MicroSilk

®

 pump motor, 

press and release for each setting: ON or OFF.  A  
20-minute decreasing timer will be initiated when the 
pump motor starts. Press and hold the Pump icon to cycle 
through each pump setting. The Pump icon lights when 
the water is at operating level and the LCD displays  
“System Ready”. The LCD will display “Pump On”, or 
“Pump Off” when the key is pressed. It also toggles  
between Temperature and Timer at 5 second intervals. 
“Low Water” is displayed for 5 seconds if no water is 
detected.

LED Light Icon
Hold the key for less than two (2) seconds to turn the 
lights Off or On. Hold the key for more than two (2) 
seconds to change modes. The Light icon should remain 
lit as long as the bath is connected to a power supply. 
This function has a two-hour timer and remembers the 
last mode. The LCD displays “Light On” or “Light Off” 
while the key is pressed for less than two (2) seconds, 
“Light Cycle” is displayed if pressed for more than two (2) 
seconds.

Customized Settings

The 12-character LCD display can be customized 
by pressing the two Diagnostic Function icons 
simultaneously for five (5) seconds, while the system 
is off. Note: Use the above figure to locate the icons. A 
menu will be displayed to choose the following: Product 
Test Diagnostics, Temperature (°F or °C) and Language 
(English or Spanish).

Menu Instructions

Use the top Diagnostic Function icon to scroll through the 
different menu items. Use the bottom Diagnostic Function 
icon to change an option. For example, press and 
release the top icon to change from Product Test to the 
Temperature option. Press and release the bottom icon to 
change the temperature display from °F (Fahrenheit) to °C 
(Celsius).

Product Test Diagnostics

After selecting the Product Test option from the menu, 
the unit will perform a series of tests to confirm correct 
installation of components. The test will begin by 
displaying the configuration number, followed by the 
software revision number. Next, the display will then test 
the Temperature and Low Water level sensor (ITW-209). 
Next, each of the six (6) icon buttons will begin to light. 
Press the illuminated button to proceed to the next icon. 
After the icon test, the LED Light unit will be tested. If 
you receive an error on any of the tests, confirm proper 
installation of component to the correct control box. (See 
the CONTROL BOX CONNECTIONS section). 

Remote Control

The Signature Edition control system includes a 
waterproof floating Universal Remote Control. It controls 
all bath functions plus a TV, DVD, CD, etc., which can 
be heard through the Sound Immersion Transducers 
(optional).

SIGNATURE EDITION  

MICROSILK

®

 TOUCHPAD

m

IR for Remote

LED Light

For Diagnostic Functions

For Diagnostic Functions

MicroSilk™ On/Off

Display Panel

®

OPERATING INSTRUCTIONS, FEATURES, AND CONTROLS (cont.)

Summary of Contents for forma AirMasseur RE630PS

Page 1: ...responsible for insuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit If the carton shows sign of damage inspect the product before accepting...

Page 2: ...e AEC carton aside to be installed later 4 Cardboard bath well protector Each bath is provided with a cardboard bath well protector that should be kept in the unit throughout the bathroom construction...

Page 3: ...four existing 3 8 holes located in the bottom four corners of the skirt to mark where to drill the pilot holes for the four locating studs If installing on a wooden floor 1 4 6mm holes are required a...

Page 4: ...IR BLOWER section of this manual before proceeding to the next step 20 Reattach the skirt to the bath by positioning the skirt on the bath and fastening the 5 16 nut and washers to the 5 16 leveling b...

Page 5: ...ted by any control device Likewise the electrical service from the GFCI to the bath control should be direct and not interrupted by a switch Never use a switch in conjunction with a control device Thi...

Page 6: ...nature Edition AirMasseur Control Box The blower junction box must be connected into a dedicated 240v 15A 50 or 60Hz GFCI protected circuit See Figure 9a Control Box Light Cable Check Valve Blower Blo...

Page 7: ...routed away from the equipment or other heat producing compo nents of the unit Figure 10 Standard Premier Edition MicroSilk m MICROSILK Control Box Dedicated 120V 50 or 60 Hz GFCI Protected Service G...

Page 8: ...e blower s check valve Use screws to attach the pipe to the check valve and route the hose to the remote blower tubing floor cutout location CAUTION Do NOT use ABS or PVC glue near the blower it could...

Page 9: ...NSTALLATION INSTRUCTIONS cont ACRYLIC EQUIPMENT CABINET INSTALLATION The Jason Acrylic Equipment Cabinet AEC can be used to house the bath equipment that cannot be remote mounted away from the bath Th...

Page 10: ...the appropriate barb using the clamp provided Assure the line will allow proper drainage to the bath fitting The hose must have a continuous drop from the barb to the fitting See Figure 14c Figure 14...

Page 11: ...olish No 2 available from the Jason Dealer It is always preferable to protect the acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the...

Page 12: ...pt that the Blower junction box must be connected into one dedicated 240v 15 Amp GFCI circuit PREMIER EDITION AIRMASSEUR Jason s Premier Edition AirMasseur system incorporates all the features of the...

Page 13: ...ord to ozone unit Figure 17 NOTE This diagram Figure 17 also applies to 50 Hz 240v controls and power supply systems MICROSILK CONTROL BOX CONNECTIONS STANDARD EDITION MICROSILK Jason s Standard Editi...

Page 14: ...r LED light G Ozone Unit pre wired to control box PREMIER EDITION MICROSILK Jason s Premier Edition MicroSilk system incorporates all the features of the Standard Edition system and includes the benef...

Page 15: ...er is powered a digital control with LCD display window low water and temperature sensors and a 20 minute timer Signature Touchpad A main control touchpad mounted on the bath deck features a LCD reado...

Page 16: ...LED light if installed Press the icon for less than two 2 seconds to turn the lights Off or On Hold the icon for more than two 2 seconds to change modes This function has a two 2 hour timer and remem...

Page 17: ...TIONS section Remote Control The Signature Edition control system includes a waterproof floating Universal Remote Control It controls all bath functions plus a TV DVD CD etc which can be heard through...

Page 18: ...ol touchpad installed on the bath deck a floating waterproof Universal Remote Control is provided with all Signature Edition MicroSilk baths This remote control provides the same control functions as...

Page 19: ...icon is used to activate the MicroSilk unit and the 20 minute timer Press the icon the first time to start the MicroSilk unit Press the icon again to shut off the MicroSilk unit LED Light Icon The LED...

Page 20: ...ote Use the above figure to locate the icons A menu will be displayed to choose the following Product Test Diagnostics Temperature F or C and Language English or Spanish Menu Instructions Use the top...

Page 21: ...ass cleaner and a soft wet cloth or sponge Do not run the hydrotherapy system with foaming cleaners or soaps Rinse the bath thoroughly after cleaning USER MAINTENANCE INSTRUCTIONS SURFACE MAINTENANCE...

Page 22: ...overheated and thermal protection device deactivated motor possibly low voltage b GFCI tripped a Check that blower has sufficient ventilation and that the intake into the blower is not blocked Clear...

Page 23: ...ice deactivated motor Possibly low voltage b GFCI tripped c Water level fell below recommended level a Make sure motor air cooling vents are not blocked clear and allow motor to cool down Check servic...

Page 24: ...trictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physici...