4. AirMasseur
®
Equipment
The AirMasseur
®
equipment may be shipped separate-
ly from the bath. The blower is prewired to the control
box. The control box has a 36" (91cm) cord with plug
end (junction box connection for 240v). The blower
control box is mounted on a stand. During installation,
the control box stand and controls must be positioned
horizontally and located to permit access for inspection
and servicing.
Standard/Premier Edition AirMasseur
®
Control Box
(120v). The blower control box must be plugged into a
dedicated 120v (volt), 15A (amp), 60Hz (hertz), Ground
Fault Circuit Interrupter (GFCI) protected circuit. See
Figure 9.
INSTALLATION INSTRUCTIONS (cont.)
Standard/Premier Edition AirMasseur
®
Control Box
(240v). The blower control box must be plugged into a
dedicated 240v (volt), 15A (amp), 50Hz (hertz), Ground
Fault Circuit Interrupter (GFCI) protected circuit. See
Figure 9.
Signature Edition AirMasseur
®
Control Box.
The blower junction box must be connected into a
dedicated 240v, 15A, 50 or 60Hz, GFCI protected
circuit. See Figure 9a.
Control Box
Light Cable
Check Valve
Blower
Blower Mount
Control Box
Keypad Cable
Light Cable
Keypad Cable
Low Water/Temp Cable
(Signature Edi
ti
on)
Check Valve
Blower
Blower Mount
Ground - Green Wire
Neutral - White Wire
Hot - Black Wire
Dedicated
120V, 50 or 60 Hz
GFCI Protected
Service
L2
L1
GROUND
DEDICATED
240V,50 or 60 Hz
GFCI PROTECTED
SERVICE
NOTE: USE THE ABOVE
DIAGRAM FOR 240V, 50Hz
OR 60Hz SYSTEMS.
L2
L1
GROUND
DEDICATED
240V,50 or 60 Hz
GFCI PROTECTED
SERVICE
O
R
Figure 9
Standard/Premier Edition
AirMasseur
®
Figure 9a
Signature Edition
AirMasseur
®
Control Box
Light Cable
Check Valve
Blower
Blower Mount
Control Box
Keypad Cable
Light Cable
Keypad Cable
Low Water/Temp Cable
(Signature Edi
ti
on)
Check Valve
Blower
Blower Mount
Ground - Green Wire
Neutral - White Wire
Hot - Black Wire
Dedicated
120V, 50 or 60 Hz
GFCI Protected
Service
L2
L1
GROUND
DEDICATED
240V,50 or 60 Hz
GFCI PROTECTED
SERVICE
NOTE: USE THE ABOVE
DIAGRAM FOR 240V, 50Hz
OR 60Hz SYSTEMS.
L2
L1
GROUND
DEDICATED
240V,50 or 60 Hz
GFCI PROTECTED
SERVICE