Jason International, Inc. •
501.771.4477
Page 7 of 24
Customer Service : 800.255.5766
Copyright © 2013 Jason International.
5. MicroSilk Equipment
The MicroSilk equipment will be shipped separate
from the bath with the AEC Equipment Cabinet. Follow
the instructions for the AEC EQUIPMENT CABINET
INSTALLATION section of this owner’s manual. The
control box has a 36" (91cm) cord with plug end (junc-
tion box connection for 240v). The MicroSilk control
box is mounted on a stand.
Standard/Premier Edition MicroSilk
®
Control Box
(120v). The MicroSilk control must be plugged into a
dedicated 120v, 20A, 60Hz, GFCI protected circuit.
See Figure 10.
INSTALLATION INSTRUCTIONS (cont.)
Standard/Premier Edition MicroSilk
®
Control Box
(240v). The MicroSilk control must be plugged into a
dedicated 240v, 15A, 60Hz, GFCI protected circuit.
See Figure 10.
Signature Edition MicroSilk
®
Control Box (240v).
The MicroSilk control must be plugged into a dedicated
240v, 15A, 60Hz, GFCI protected circuit.
See Figure 10a.
DANGER: Do not alter the factory installed wiring. All
building materials and wiring should be routed away
from the equipment or other heat-producing compo-
nents of the unit.
Figure 10
Standard/Premier Edition
MicroSilk
®
m
MICROSILK™
Control Box
Dedicated
120V, 50 or 60 Hz
GFCI Protected
Service
Ground
L2
L1
Dedicated
240V, 50 or 60 Hz
GFCI Protected
Service
L2
L1
GROUND
DEDICATED
240V,50 or 60 Hz
GFCI PROTECTED
SERVICE
NOTE: USE THE ABOVE
DIAGRAM FOR 240V, 50Hz
OR 60Hz SYSTEMS.
Control Box
Ground - Green Wire
Neutral - White Wire
Hot - Black Wire
Control Box
Dedicated
120V, 50 or 60 Hz
GFCI Protected
Service
Ground
L2
L1
Dedicated
240V, 50 or 60 Hz
GFCI Protected
Service
L2
L1
GROUND
DEDICATED
240V,50 or 60 Hz
GFCI PROTECTED
SERVICE
NOTE: USE THE ABOVE
DIAGRAM FOR 240V, 50Hz
OR 60Hz SYSTEMS.
Control Box
Ground - Green Wire
Neutral - White Wire
Hot - Black Wire
Figure 10a
Signature
Edition MicroSilk
®
m
AIRMASSEUR
®
& MICROSILK
®
SIGNATURE EDITION ONLY
L2-WHITE WITH
RED MARK
L1-BLACK
GND-GREEN
FROM BLOWER CONTROL
FROM MICROSILK CONTROL
L2
240 V
L1
NO CONNECTION
(LOAD NEUTRAL)
BREAKER BOX
Note: The load neutral terminal is not used. There should be no connection to the load neutral
terminal on the GFCI circuit breaker. The green wire (GND-GREEN) is the equipment ground
and should be connected to the neutral bus found in the main breaker box.
BREAKER BOX CONNECTIONS