background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 8 of 12

 

 

 

 

Customer Service :  800.255.5766 

FEATURES

The Jason Signature Edition Air-Whirlpool digital touchpad is 

used to access all the functions of the two (2) control boxes 

used on the Jason Signature Edition Air-Whirlpool bath. The 

Air-Whirlpool’s  3-speed  whirlpool  pump  can  be  operated 

simultaneously or separately from the blower.

WHIRLPOOL ON/OFF, SPEED CONTROL

To control the operation of the whirlpool pump motor, press 

and hold for each setting: High, Medium, Low, or Off. A 20 

minute decreasing timer will be initiated when the pump motor 

starts. Press and release the Pump icon once to display the 

current pump setting. The Pump icon lights when the water is 

at operating level and the LCD displays “System Ready”. The 

LCd will display “pump Off”, “pump High”, “pump Medium”, or 

“Pump Low” when the key is pressed. It also toggles between 

Temperature and Timer at 5 second intervals.  “Low Water” 

is displayed for 5 seconds if no water is detected.  

OPTION (“O” ICON)

This key is reserved for future options.

BLOWER ON/OFF, MODES 

To control the operation of the blower, simply press and hold 

the key to change the setting to Constant, Wave, Pulse or 

Off. A 20 minute decreasing timer will be initiated when the 

blower motor starts. Press and release the Blower icon once 

to display the current blower mode and speed. The Blower 

icon should remain lit as long as the bath is connected to a 

power supply. The LCD will display “Const Air” and blower 

speed, “Wave Air” and blower speed, or “Pulse Air” and blower 

speed, while the key is pressed. The time remaining on the 

purge cycle is displayed after the bath has drained. “Purge 

Stop” is displayed while the key is pressed during the purge 

cycle. This action will terminate the purge cycle. The mode 

settings will be remembered on the next startup.

BLOWER SPEEDS

Hold the key in Constant mode to go from High to Low then 

release and hold again to go from Low to High. Hold the key in 

Wave and pulse mode to go from High to Medium and Medium 

to High. The system remembers the last speed setting on 

the next startup. The Blower Speeds icon will light up when 

the blower is running. The LED displays the blower speed 

from “10” (Low) or “55”(Med) to “99” (High) while the key is 

pressed. You can reduce the auto purge idle time from 20 

minutes to 10 minutes, by pressing and holding the key for 

more than 5-seconds during the purge idle period.

LED LIGHT 

Hold the key for less than two (2) seconds to turn the lights 

Off or On. Hold the key for more than two (2) seconds to 

change modes. The Light icon should remain lit as long as 

the bath is connected to a power supply. This function has 

a two-hour timer and remembers the last mode. The LCD 

displays “Light On” or “Light Off while the key is pressed 

for less than two (2) seconds, “Light Cycle” is displayed if 

pressed for more than two (2) seconds. 

CUSTOMIZED SETTINGS

The 12 character LCD display can be customized by pressing 

the  Blower  and  Blower  Speeds  icon  simultaneously  for 

five (5) seconds, while the system is off. 

NOTe

: The Blower 

Speeds icon will not be illuminated during this process. Use 

the above figure to locate the icons and LCd display. A menu 

will be displayed to choose the following: Purge 24, (starts 

the blower every 24 hours for two (2) minutes at the time 

the purge was set), Product Test Diagnostics, Temperature 

(F or C) and Language (English or Spanish).

MENU INSTRUCTIONS

Use  the  Blower  icon  to  scroll  through  the  different  menu 

items. Use the Blower Speeds icon to change an option. 

For example, press and release the Blower icon to change 

from Purge 24 to Product Test, press and release again to 

arrive  at  the  Temperature  option.  Press  and  release  the 

Blower Speeds icon to change the temperature display from 

F (Fahrenheit) to C (Celsius).

PRODUCT TEST DIAGNOSTICS

After selecting the Product Test option from the menu, the unit 

will perform a series of tests to confirm correct installation of 

OPERATING THE SIGNATURE  EDITION 

AIR-WHIRLPOOL TOUCHPAD

IR  FO R  R EM O TE

BLO W ER  O N /O FF, M O D ES

BLO W ER  SPEED S

O PTIO N

O

LED  LIG H T

JASON

W H IR LPO O L O N /O FF, SPEED  C O N TR O L

SIG N ATU R E ED ITIO N  AIR -W H IR LPO O L (FO R M A)

S Y S T E M

 R E ADY

Summary of Contents for forma Series

Page 1: ...by warranty and is the responsibility of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INSTALLATION Inspect Owner s Manual forma Air Whirlpool Baths INSTALLATION OP...

Page 2: ...lower and pump mount s to rest firmly on the floor The bottom of the blower and pump mount s must be secured and level with the bottom of the bath We recommend securing the blower and pump mounts to t...

Page 3: ...ons are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the unions hand tight then loosen the unions s and check the O ring sea...

Page 4: ...r GFCI In the unlikely occurrence of a current imbalance in the power conductors the GFCI will interrupt the power to the bath GROUNDING IS REQUIRED Theunitshouldbeinstalledbyaqualifiedservicerepresen...

Page 5: ...he same time everyday See Operating the Signature Edition Air Whirlpool Touchpad on pages 8 9 REMOTE CONTROL FEATURES In addition to the main control touchpad installed on the bath deck a floating wat...

Page 6: ...box must be plugged into a 120v 15 amp GFCI dedicated circuit H Pre wired power cord to the blower I Air whirlpool control box connections SIGNATURE EDITION AIR WHIRLPOOL PARTS LIST Pump Pump Control...

Page 7: ...jets Blowers provided on Jason Air Whirlpool baths are factory tested when assembled and again retested after installation on the Air Whirlpool bath STANDARD EDITION AUTOMATIC PURGE Fifteen minutes af...

Page 8: ...mandMedium to High The system remembers the last speed setting on the next startup The Blower Speeds icon will light up when the blower is running The LED displays the blower speed from 10 Low or 55 M...

Page 9: ...again to increase the blower speed until the desired intensity is reached The blower will return to its highest speed on any mode change Option The Option icon is used to operate an optional LED ligh...

Page 10: ...commercially available plastic polish i e Novus Plastic Polish No 2 available at your Jason dealer followed by an application of acrylic paste wax Buff the surface with a clean soft cloth Do not use s...

Page 11: ...le was disabled a Remove power to the bath either by the circuit breaker or by unplugging and replugging the blower from the supply outlet PumpSystem of Air Whirlpool Bath Symptoms Possible Causes Rec...

Page 12: ...tors hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a...