Jason International, Inc. •
501.771.4477
Page 9 of 12
Customer Service : 800.255.5766
OPERATING THE STANDARD EDITION
AIR-WHIRLPOOL TOUCHPAD
FEATURES
The Jason Standard Edition Air-Whirlpool touchpad is used to
access all of the functions of the pump and blower controls.
The Air-Whirlpool’s 1-speed whirlpool pump can be operated
simultaneously or separately from the blower.
OPERATING INSTRUCTIONS
Pump On/Off
The Pump icon is used to activate the whirlpool pump and
the 20-minute timer. pressing the icon the first time starts the
pump. Pressing the icon again will shut the pump off.
Blower On/Off, Mode
The Blower icon is used to activate the blower and the 20-
minute timer. pressing the icon the first time starts the blower
in the constant high speed mode. Pressing the icon again
begins the wave mode, indicated by a slow flashing light.
Pressing the icon a third time will change the blower to pulse
mode. This is indicated by a rapid light flash.
Blower Speeds
The Blower Speeds icon is used to increase or decrease
the blower speed once the blower is on. Press and hold the
icon to decrease the blower speed until the desired intensity
is reached, then release. Press and hold the icon again
to increase the blower speed until the desired intensity is
reached. The blower will return to its highest speed on any
mode change.
Option
The Option icon is used to operate an optional LED light (if
installed). Press the icon for less than two (2) seconds to
turn the lights Off or On. Hold the icon for more than two (2)
seconds to change modes. This function has a two (2) hour
timer and remembers the last mode.
O
Blower Speeds
Option
Blower On/Off, Mode
Pump On/Off
OPERATING THE SIGNATURE EDITION AIR-WHIRLPOOL TOUCHPAD (cont.)
components. The test will begin by displaying the configuration
number, followed by the software revision number. Next,
the auxiliary control box will be tested to ensure proper IR
communication. The display will then test the Temperature
and Low Water level sensor (ITW-209). Next, each of the six
(6) icon buttons will begin to light. Press the illuminated button
to proceed to the next icon. After the icon test, the pump will
start for two (2) seconds on the high setting. Lastly, the LED
Light unit will be tested. If you receive an error on any of the
tests, confirm proper installation of component to the correct
control box. (See
Figure 4A
on page 6.)
REMOTE CONTROL
The Signature Edition control system includes a waterproof
floating Universal remote Control. It controls all bath functions
plus a TV, DVD, CD, etc. which can be heard through the
Sound Immersion Transducers (optional).