background image

Jason International, Inc.  •  

 

501.771.4477  

    

Page 15 of 16

    

Customer Service :  800.255.5766 

Copyright © 2014 Jason International.

IMPORTANT SAFETY INSTRUCTIONS

InsTruCTIOns PerTaInIng TO THe rIsk OF FIre, eleCTrIC sHOCk, Or InJurY TO Per-

sOns.

This manual contains information and instructions for proper operation and maintenance of your therapy bath.  Failure to follow these 
instructions could result in personal injury, electrical shock, or fire.

warnIng: when using this unit, basic precautions should always be followed, including the following:

reaD anD FOllOw all InsTruCTIOns CareFullY

Danger:

 

TO reDuCe THe rIsk OF InJurY FOllOw THese PreCauTIOns: 

a.

  Do not permit children to use this product unless they are closely supervised at all times.

B.

  Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufac-

turer.

C.

  The water in a  therapy bath should never exceed 40°C (104°F). Water temperatures between 38°C (100°F) and 40°C (104°F) are 

considered safe for a healthy adult. Use time should be limited to approximately 30 minutes, followed by a shower to cool down. 
Longer exposures may result in hyperthermia. The symptoms of this condition are nausea, dizziness and fainting, and it can be 
fatal. Lower water temperatures are recommended for extended use (exceeding 10 -15 minutes) and for young children.

D.

  Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, 

pregnant or possibly pregnant women should limit therapy bath water temperatures to 38°C (100°F).

e.

 The use of drugs or alcoholic beverages before or during therapy bath use may lead to unconsciousness with the 

possibility of drowning. Never use the therapy bath while under the influence of alcohol, anticoagulants, stimulants,  
antihistamines, vasoconstrictors, vasodilators, hypnotics, narcotics, or tranquilizers.

F.

  Persons with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should 

consult a physician before using a therapy bath.

g.

  Persons using medication should consult a physician before using a therapy bath since some medication may induce drowsiness 

while other medication may affect heart rate, blood pressure, and circulation.

Danger:

 

 

To reduce the risk of injury, enter and exit the bath slowly. 

Do not operate this unit unless the suction cover is attached over 

the suction inlet fitting and the jet assemblies are installed.  There should be at least two (2) inches of water above the highest jet 
location during therapy bath operation.

 neVer run unIT DrY.

warnIng:

 

Never operate electrically connected devices in or near the bath. Never drop or insert any object into any opening.

This unit must be connected to a supply circuit that is protected by a GFCI. Such a device should be installed by a licensed electrician 
and should be tested on a regular basis (at least monthly). To test the GFCI push the 

TesT

 button. The GFCI should interrupt the 

power. Push the 

reseT

 button and the power should be restored. If the GFCI fails to operate in this manner, there is the possibility 

of an electric shock. 

DO nOT use. 

Disconnect the unit and have the problem corrected by a qualified service technician. 

To avoid the possibility of personal injury and discoloration of the acrylic surface, the inlet water temperature should not exceed 
40°C (104°F). The bath should be drained after each use. Each bather should start their bath with fresh water. Do not use oil base 
additives in your therapy bath.

CauTIOn: 

Do not use harsh abrasives or solvents for cleaning this unit.

InsTaller/Owner Bears all resPOnsIBIlITY TO COMPlY wITH all sTaTe  

anD lOCal CODes wHen InsTallIng THIs PrODuCT.

saVe THese InsTruCTIOns

Summary of Contents for HSC650

Page 1: ...ge In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been avoided by inspection or testing prior to installation If the carton shows s...

Page 2: ...ructions herein SeeUSERMAINTENANCEINSTRUCTIONSsectionofthis owner smanualforhumidityandmoldpreventionsuggestions prior to Installation 1 TheHomeSpabathisequippedwithseparatebathpumps and blower suppor...

Page 3: ...1 1 4 OVERLOAD PROTECTOR 1 5A TIME DELAY FUSE 1 4 x 1 1 4 TO MEDIA DEVICE REAR LEFT TO MEDIA DEVICE FRONT LEFT TO MEDIA DEVICE REAR RIGHT TO MEDIA DEVICE FRONT RIGHT NOTE THE NEGATIVE TERMINAL IS IDEN...

Page 4: ...g If the unit leaks with the unions hand tight then loosen the union s and check the O ring seal to ensure it is properly seated INSTALLATION INSTRUCTIONS cont 12 The acrylic surface of this bath has...

Page 5: ...w piping to the elbow of the existing piping INSTALLATION INSTRUCTIONS cont ELECTRICAL Electrical Power Supply These instructions are written assuming 60Hz 120V power supply Special notations are also...

Page 6: ...d that is temporarily secured to the packing board for shipping These boxes must remain on the control box bracket so that the two boxes can communicate properly through their infared communication fe...

Page 7: ...igure 4 Home Spa Control box connections C Eight pin mini DIN terminal for the Home Spa U1 keypad D Six pin mini DIN terminal for LED light E Six pin mini DIN terminal for installation of the water se...

Page 8: ...Refer to the Instruction Manual provided with the remote control for detailed instructions Automatic Purge Twenty 20 minutes after the control has shut off the blower will start again for a two minute...

Page 9: ...on on the Air Whirlpool bath These pumps are of efficient design incorporating high quality long life seals which provide superior service However should the pump need service suction and discharge un...

Page 10: ...r simply press and release to change the setting to Constant Wave Pulse or Off A 20 minute decreasing timer will be initiated when the blower motor starts Press and hold the Blower icon to cycle throu...

Page 11: ...mperature display from F Fahrenheit to C Celsius Product Test Diagnostics AfterselectingtheProductTestoptionfromthemenu theunit will perform a series of tests to confirm correct installation of compon...

Page 12: ...ur serial number proof of purchase and model number This will insure a quick response on warranty items The serial number can be foundonthefrontpageofthismanualoronthesmallcardadhered to the back of t...

Page 13: ...uit between bath and blower breaker box b Refer to installer dealer c Other items are connected to the same circuit c Refer to installer dealer Blower does not shut off a Defective keypad or timer a R...

Page 14: ...tion or discharge blocked a Remove obstruction b Suction air leak System usu ally surges b Make sure union is tight on suction side of the purmp Pump does not manually shutoff a Defective keypad or co...

Page 15: ...of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure cir...

Page 16: ...rnational Inc 501 771 4477 Page 16 of 16 Customer Service 800 255 5766 Copyright 2014 Jason International Jason International Inc 8328 MacArthur Drive North Little Rock Arkansas 72118 www jasoninterna...