Jason International, Inc. •
501.771.4477
Page 4 of 9
Customer Service : 800.255.5766
ELECTRICAL
Electrical Power Supply:
These instructions are written
assuming 60Hz, 120v power supply. Special notations
are also included for export versions of the pump, control
equipment, and power supply.
WARNING: Verification of electrical requirements MUST
be made before installation. Refer to the equipment labels
for voltage and frequency requirements.
NOTE:
Verify that the electrical service matches either the
120v or 240v system requirements for this bath.
NOTE:
The bath is designed for indoor use only. The electri-
cal equipment must not be exposed to direct or indirect water
or moisture contact. The electrical equipment must also be
protected from dust and other airborne debris before, during,
and after installation.
1.
Electrical Service:
A licensed electrician must provide
the “dedicated” electrical service protected by a GFCI.
The location of the GFCI must be at least five (5) feet (152
cm) away from the inside surface of the bath, accessible
for regular testing. Use copper conductors only.
DANGER — RISK OF ELECTRIC SHOCK:
Connect
only to a circuit protected by a Ground Fault Circuit In-
terrupter (GFCI). In the unlikely occurrence of a current
imbalance in the power conductors, the GFCI will interrupt
the power to the bath.
WARNING:
The electrical service to the GFCI must not be
interrupted by any control device. Likewise, the electrical
service from the GFCI to the bath control should be direct
and not interrupted by a switch. Never use a switch in
conjunction with a control device.
This will VOID THE
MANUFACTURER’S WARRANTY.
2.
GROUNDING IS REQUIRED
The unit should be installed by a qualified service
representative and properly grounded.
3.
INSTALL SERVICE CONNECTION AT LEAST 6” (15cm)
ABOVE SUB FLOOR.
ALL LOCAL AND STATE ELECTRICAL AND PLUMB-
ING CODES MUST BE OBSERVED
. Where there are no
local codes the
National Electric Code (NEC) and Uni-
form Plumbing Code (UPC)
shall be observed. It is the
responsibility of the installer/owner to determine specific
code compliance prior to installation of the product.
NOTE:
In the Commonwealth of Massachusetts, in-
stallation is to be done by a Massachusetts licensed
plumber.
4.
Integrity Whirlpool Control Box (120v,60Hz):
This
Whirlpool bath is provided with an Air On/Off switch.
The pump is pre-wired to a control box which has a 36”
cord. Connect the pump to a GFCI (Ground Fault Circuit
Interupter) with 120v (volt), 20A (amp), 60HZ (hertz) elec-
trical service with a service ground receptacle dedicated
for use by this bath.
5.
Export Integrity Whirlpool Control Box (240v,60Hz):
This Whirlpool bath is provided with an Air On/Off switch.
The pump is pre-wired to a control box which has a 36”
INSTALLATION INSTRUCTIONS (cont.)
Figure 3