background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 5 of 9

  

 

 

Customer Service :  800.255.5766 

INSTALLATION INSTRUCTIONS (cont.)

cord. Connect the pump to a GFCI (Ground Fault Circuit 
Interupter) with 240v (volt), 15A (amp), 60HZ (hertz) elec-
trical service with a service ground receptacle dedicated 
for use by this bath.

6.

 Export Integrity Whirlpool Control Box (120v,50Hz): 

This Whirlpool bath is provided with an Air On/Off switch. 
The pump is pre-wired to a control box which has a 36” 
cord. Connect the pump to a GFCI (Ground Fault Circuit 
Interupter) with 120v (volt), 20A (amp), 50HZ (hertz) elec-
trical service with a service ground receptacle dedicated 
for use by this bath.

7. 

Export Integrity Whirlpool Control Box (240v,50Hz): 

This Whirlpool bath is provided with an Air On/Off switch. 
The pump is pre-wired to a control box which has a 36” 
cord. Connect the pump to a GFCI (Ground Fault Circuit 
Interupter) with 240v (volt), 15A (amp), 50HZ (hertz) elec-
trical service with a service ground receptacle dedicated 
for use by this bath.

DANGER: Do not alter the factory installed wiring.

 

All building materials and wiring should be routed away 
from the pump or other heat-producing components of 
the unit.

CLEANING

1. 

Remove all loose debris.

 Construction plaster or excess 

grout can be removed with  the use of a wood (edge) 
trowel.

2. 

Paint  or  tar  stains

  may  need  to  be  removed  with  a 

cleaner such as paint thinner, turpentine, or isopropyl 
alcohol  (rubbing  alcohol).  Never  allow  the  cleaner  to 
soak against the acrylic surface for long periods of time. 

Always rinse the surface immediately following the 

use of cleaners.

3.  Follow  the  manufacturer’s  instructions  for  safe  use  of 

cleaning products. If the surface becomes scratched or 
dulled, it may be restored by using a quality plastic polish, 
like Novus Plastic Polish No. 2 (available from the Jason 
Dealer). 

It is always preferable to protect the acrylic 

surface during installation to minimize cleanup and 

prevent surface damage.

WATER TESTING

Before finishing the installation, it is recommended that the 
bath be water tested and the plumbing tested for leaks. 

1. 

Before water testing the bath

, make sure any pump 

unions are hand tight. Do not over tighten or use a pipe 
wrench. This will damage the unions and cause leaking. 
If the unit leaks with the unions hand tight, then loosen 
the unions(s) and check the O-ring seal to ensure it is 
properly seated.

2. 

Fill and operate the bath.

 Close the drain and fill the 

bath with water to at least 10 inches [25 cm] below the 
bath deck. The inlet temperature should not exceed 104°F 
(40°C) as this could damage the acrylic surface. Refer 
to the FILLING AND DRAINING section of this owner’s 
manual for more information.

NEVER  RUN  THE  WHIRLPOOL  PUMP  WITHOUT 

ENOUGH  WATER  IN  THE  BATH  TO  COVER  THE 

JETS.

3.  Before starting the pump, direct the jet nozzles downward 

to prevent the possibility of water splashing from the bath.  
Refer to the 

OPERATING INSTRUCTIONS, FEATURES, 

AND CONTROLS

 section of this Owner’s Manual.

4.  

Inspect the plumbing for leaks.

5. 

Turn the equipment Off and then drain the water.

 The 

bath unit and its plumbing are designed to drain after each 
use whether used as a whirlpool bath, air bath, soaking 
bath, or when taking a shower.

Summary of Contents for Integrity A6060

Page 1: ...y of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INSTALLATION Inspect plumbing and bath surface for missing or damaged components Alert your dealer of any discrep...

Page 2: ...x 43 254 J4260 60 x 42 x 20 5 43 1 36 x 17 36 3 152 x 107 x 52 162 91 x 43 177 J4266 66 x 42 x 20 5 46 1 36 x 17 41 9 168 x 107 x 52 174 91 x 43 204 J4272 72 x 42 x 20 5 49 1 36 x 17 33 2 183 x 107 x...

Page 3: ...the bath in the area of intended installation 4 Finishplumbingrough inofdrainandoverflowassembly At this time considerations should be made for the position and mounting of the faucet set as well as a...

Page 4: ...FCIwillinterrupt the power to the bath WARNING TheelectricalservicetotheGFCImustnotbe interrupted by any control device Likewise the electrical service from the GFCI to the bath control should be dire...

Page 5: ...ce for long periods of time Always rinse the surface immediately following the use of cleaners 3 Follow the manufacturer s instructions for safe use of cleaning products If the surface becomes scratch...

Page 6: ...JETS Before starting the pump direct the jet nozzles downward to prevent the possibility of water splashing from the bath When bath is in use turn the unit Off before draining the water The bath unit...

Page 7: ...RE WORK IS STARTED HUMIDITY Warning Avoid high humidity levels in your home Mold mildew fungi and bacteria which may be harmful to health thrive in areas with continued high humidity levels therefore...

Page 8: ...o the company within thirty 30 days from the occurrence thereof Written permission must be obtained by the retailer or distributor from the Company before any equipment claimed defective is returned f...

Page 9: ...cs narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a hydrotherap...

Reviews: