This manual contains all of the information needed for the 
proper operation of this Integrity

®

 Whirlpool bath. The Whirlpool 

bath has been designed to provide years of relaxing trouble-
free service, provided the unit is maintained and operated in 
accordance with these instructions.

Thoroughly  clean  and  disinfect  the  unit  as  described  in 
the 

CLEANING

  section  of  the 

USER  MAINTENANCE 

INSTRUCTIONS

 section of this owner’s manual before its 

first use and periodically thereafter.

CAUTION:

 Keep hair, towels, and clothing away from the 

suction  fitting  whenever  the  Whirlpool  equipment  is  On. 
Never  operate  the  equipment  with  the  suction  cover  off, 
doing  so  voids  the  manufacturer’s  warranty--it  is  a  safety 
cover designed to eliminate the potential of hair and body 
entrapment.

All  Jason  Integrity

®

  Whirlpool  baths  are  pre-plumbed  at 

the factory with standard equipment.  Standard equipment 
includes five (5) or more directional hydrotherapy jets, and 
an air actuated On/Off switch.

WARNING: Before operating refer to the instructions at 

the end of this owner’s manual pertaining to the risk of 

fire, electric shock, or injury to persons.

FILLING AND DRAINING

Close the drain and fill the bath with water at least two (2) inches 
(50mm) above the jets. The inlet temperature should not exceed 
40°C (104°F) as this could damage the acrylic surface. 

CAUTION:  NEVER  RUN  THE  WHIRLPOOL  PUMP 

WITHOUT ENOUGH WATER IN THE BATH TO COVER 

THE JETS.

Before starting the pump, direct the jet nozzles downward 
to prevent the possibility of water splashing from the bath.  
When bath is in use, turn the unit Off before draining the 
water. The bath unit and its plumbing are designed to drain 
after each use whether used as a hydrotherapy bath, soaking 
bath, or just taking a shower.

AIR ON/OFF BUTTON

The Air On/Off button provides a safe 
and convenient method for controlling 
the  Whirlpool  bath.  The  Air  On/Off 
button is factory mounted onto the bath 
prior to shipment. 

See Figure 3

 for the 

location of the Air On/Off button (air 
actuator) on the Whirlpool bath. Fill the 
bath to at least two (2) inches above 
the highest jet and press the Air On/
Off button to start the whirlpool pump. 
Press the Air On/Off button again to 
stop the whirlpool pump.

NOTE: 

If the unit fails to operate, check the breaker panel 

to insure that the circuit breaker is On. Check the ground 
fault circuit interrupter (GFCI) by testing and resetting it. If 
the unit still fails to operate contact an authorized service 
technician  for  repair. 

DO  NOT  ATTEMPT  TO  RESOLVE 

THE PROBLEM.

JETS

Five or more strategically placed whirlpool jets are provided 
for complete enjoyment of the bath. The jets are specially 
designed for maximum whirlpool action with direction and flow 
control. Changing the direction of the jets will concentrate the 
massaging jet stream to the area of preference and turning 
the flange of the jet will adjust the amount of flow. 

PUMP

The pump provided on Integrity

®

 Whirlpool baths is factory 

tested when assembled onto the bath. The pump is designed to 
incorporate high quality, long-life seals which provide superior 
service. However, should the pump need service, use the 
suction and discharge unions provided for easy removal. 

Summary of Contents for Integrity A6060

Page 1: ...y of the installer ALL WARRANTY CLAIMS ON ACRYLIC SURFACE DAMAGE MUST BE MADE PRIOR TO INSTALLATION Inspect plumbing and bath surface for missing or damaged components Alert your dealer of any discrep...

Page 2: ...x 43 254 J4260 60 x 42 x 20 5 43 1 36 x 17 36 3 152 x 107 x 52 162 91 x 43 177 J4266 66 x 42 x 20 5 46 1 36 x 17 41 9 168 x 107 x 52 174 91 x 43 204 J4272 72 x 42 x 20 5 49 1 36 x 17 33 2 183 x 107 x...

Page 3: ...the bath in the area of intended installation 4 Finishplumbingrough inofdrainandoverflowassembly At this time considerations should be made for the position and mounting of the faucet set as well as a...

Page 4: ...FCIwillinterrupt the power to the bath WARNING TheelectricalservicetotheGFCImustnotbe interrupted by any control device Likewise the electrical service from the GFCI to the bath control should be dire...

Page 5: ...ce for long periods of time Always rinse the surface immediately following the use of cleaners 3 Follow the manufacturer s instructions for safe use of cleaning products If the surface becomes scratch...

Page 6: ...JETS Before starting the pump direct the jet nozzles downward to prevent the possibility of water splashing from the bath When bath is in use turn the unit Off before draining the water The bath unit...