background image

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 2 of 5

  

 

 

Customer Service :  800.255.5766 

INSTALLATION  INSTRUCTIONS

INSTALLATION

Follow these instructions to install the soaking bath vessel, 

overflows, fill spouts, and faucetry. Electrical connection is 

not needed.  

see the user MaINTeNaNCe INsTruCTIONs on page  4 for humidity 

and mold prevention suggestions prior to Installation. 

1. 

Finish Frame

a. 

Construct a finish frame under the bath rim

 to support the 

bath lip and keep the bath deck level, which will assist 

any water draining from the deck of the bath into the 

well of the bath. This frame is not intended to support 

the full bath weight. 

 

If a

 

lateral skirt is to be used on the bath, the bath deck must 

be leveled at the correct clearance from the support foundation 

(flooring)  depending  on  the  model,  or  the  skirt  will  not  fit 

properly.

 

apply  100%  silicone

  with  water  resistant  properties 

between the water resistant backer board and the deck 

of the bath.  

see Figure 1.

 

  NOTe: 

Soaking  bath  vessels  without  an  integral  tile 

flange or tile flange kit (TFK) are not to be installed 

against the wall.

  NOTe: 

If you have purchased a model with an integral 

skirt and tile flange; factory installed lateral skirt; integral 

tile flange;  or an optional tile flange kit, modify the 

framing to support the bath lip as shown in

 Figure 2.

  

2. 

Rough-in the plumbing for the drain and overflow assembly.  

At 

this time also plan for the position and mounting of the 

faucet  set  as  well  as  all  related  plumbing.  All  overflow 

drains, fill spouts, and valves must be installed according 

to the instructions in this manual. 

3. 

level the bath and remove packing board:

a. 

Install the bath level for proper drainage. 

Jason baths are 

designed to be supported under the entire base of the 

bath. If the floor is smooth and level, the bath’s Level-

Form™ base will provide proper drainage and support

 

(see 

Figure 2

).  Mortar is required when the subfloor is 

not smooth and level; when additional sound insulation 

is desired; and/or when the bath is installed in a drop-in 

application.  In alcove installations a bed of mortar is 

recommended to aid in leveling the bath.  

NOTe:

  Do 

not use sand to install or level the bath.

b. 

remove the packing board before installing the bath

. Some  

soaking bath models may be shipped with a packing 

board  which  must  be  removed  before  installation.  

Detach the packing board from the bath. 

4. 

Protect the acrylic bath surface from damage during installation 

with a suitable material, 

i.e.

,

 cardboard and/or plastic film. 

5. 

Install the drain

 and overflow 

assembly

 onto the bath according 

to the instructions provided with the assemblies.  Position 

the bath in the area of intended installation.  

SPECIFICATIONS TABLE

INTeGrITY COlleCTION

 

Overall 

Operating 

Floor

 

Dimension 

Capacity 

loading

       Model 

L x W x H (In.) 

GAL. 

lbs/ft

2

 

B3060

60 x 30 x 20.5

29

45.6

B3260

60 x 32 x 20.5

32

45.4

B3260 SL/SR

60 x 32 x 20.5

32

47.1

B3660

60 x 36 x 20.5

37

43.9

B3660 SL/SR

60 x 36 x 20.5

37

45.8

B3666

66 x 36 x 20.5

39

41.5

B3672

72 x 36 x 20.5

45

42.0

B3672 SL/SR

72 x 36 x 20.5

45

43.9

B4260

60 x 42 x 20.5

44

42.2

B4260 SL/SR

60 x 42 x 20.5

44

44.3

B4272

72 x 42 x 20.5

49

38.1

B4272 SL/SR

72 x 42 x 20.5

49

38.9

C6060

60 x 60 x 20.5

54

40.0

D3260

60 x 32 x 20.5

36

48.6

J4260

60 x 42 x 20.5

43

42.4

J4266

66 x 42 x 20.5

46

40.3

J4272

72 x 42 x 20.5

49

38.5

L4872

72 x 48 x 20.5

56

36.8

N3660

60 x 36 x 20.5

44

53.7

N4260

60 x 42 x 20.5

49

45.3

N4272

72 x 42 x 20.5

52

45.0 

V4266

66 x 42 x 20.5

43

41.4

V4272

72 x 42 x 20.5

46

40.1

W4266

66 x 42 x 20.5

40

39.7

Reviews: