background image

© 2018 Jason

®

 Hydrotherapy  • tech@jasonhydrotherapy.com

Page 10 of 16

Customer Service :  800.255.5766

INSTALLATION INSTRUCTIONS (cont.)

REMOTE MOUNTING OF AIR BLOWER

The Jason AirMasseur

®

 system has been factory installed 

following ETL/UL Standard safety guidelines.  During 
installation, if remote mounting of the air blower is desired 
or required, the following procedures should be followed.

Note:

 

Do no remote mount the blower more than 15 

feet [4.5m] away from the air inlet of the bath.  Choose 
a location as close as possible to the bath to ensure 
maximum efficiency.

1. 

The installer must determine the layout of the 
piping; exact remote mount location; and service 
access before beginning any work.  Use 1.5” ABS 
or PVC plastic tubing.  Locate the blower in an area 
accessible for servicing.

2.  Note: A 15 foot extension set can be purchased from 

your Jason supplier, if needed.  To ensure proper 
functioning of the system, avoid remote mounting in 
a location which requires more than six (6) piping 
direction changes. A 90° direction change should be 
made up of two 45° elbows for maximum efficiency.

3.  If the blower has been factory installed, disconnect 

the blower from the air bath plumbing by removing 
the two (2) screws on the check valve outlet and 
disconnect the short piece of pipe between the 
check valve and the elbow by removing the two 
(2) screws in the elbow.  [Omit this step on baths 
where the blower is not factory installed and remote 
mounting is required.]

4.  Install the blower in the remote location. The remote 

mount location ambient air temperature should 
remain at approximately 72°F [22°C] for optimum air 
heating.

5.  Make sure the blower is well ventilated. The blower 

mount should be attached fi rmly to the fl oor.  Piping 
between the remote blower location and the bath 
can be insulated using a minimum of ½” [13mm] 
thick insulation.  Attach new piping to the elbow of 
the existing piping.

FIELD INSTALLATION OF THE WHIRLPOOL 
PUMP ASSEMBLY

The Jason Whirlpool system has been factory installed 
following ETL/UL Standard safety guidelines. For shipping 
purposes on some bath models, the Whirlpool pump 
assembly may be packaged separately and disconnected 
from the bath.

WARNING:  Any modification to the equipment is 
not recommended and will VOID the manufacturer’s 
warranty.

To install the Whirlpool Pump Assembly to the bath, the 
following procedures must be followed.

1. 

Before beginning any work, the installer is to 
determine the proper location of the pump unit and 
service access.

2.  Thread the discharge union onto the discharge of the 

pump.

3.  Thread the suction union fi tting onto the suction of 

the pump.

4.  Connect the Whirlpool Pump Assembly power cord 

to the Load line of the control box.

Caution:

 

 Hand-tighten unions only.  Over tightening may 

cause damage to the seals.

ischarge

Suction

Summary of Contents for Integrity K3060 SR

Page 1: ...e unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason Hydrotherapy is not responsible for damage that might have been avoided by inspection or testing...

Page 2: ...ulants stimulants antihistamines vasoconstric tors vasodilators hypnotics narcotics or tranquilizers F Lower water temperatures are recommended for extended use exceeding 10 15 minutes and for young c...

Page 3: ...minutes et pour les jeunes enfants F Puisque les temp ratures excessives ont un potentiel lev pour les f tus durant les premiers mois de la grossesse les femmes enceintes ou possiblement enceintes do...

Page 4: ...du fabricant DANGER Ne pas modifier le c blage install en usine Tous les mat riaux de construction et c blage doivent tre loign s de toutes sources de chaleur moduites par le abin ATTENTION Garder les...

Page 5: ...by testing and resetting it If the unit still fails to operate refer to the Trouble Shooting Guide section of this manual If the unit still fails to operate and is out of warranty contact an authorize...

Page 6: ...se the button AirMasseur Automatic Purge Fifteen 15 minutes after the blower is stopped the blower will start again for a two 2 minute purge cycle that dries the air channel WHIRLPOOL FEATURES Jason s...

Page 7: ...the bath thoroughly after cleaning SURFACE MAINTENANCE Area with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e Novus Plastic Polish No 2 avail...

Page 8: ...F 22 C 3 Drain and Overflow Install the drain and overflow assembly to the bath shell according to the instructions provided with the drain and position the bath in the area of intended installation...

Page 9: ...ioned in the area of intended installation cut the equipment support strap s to allow the equipment to rest firmly level with the bottom of the bath on the floor We recommend securing the equipment mo...

Page 10: ...alve and the elbow by removing the two 2 screws in the elbow Omit this step on baths where the blower is not factory installed and remote mounting is required 4 Install the blower in the remote locati...

Page 11: ...rol device Likewise the electrical service from the GFCI to the bath control should be direct and not interrupted by a switch Never use a switch in conjunction with a control device This will VOID THE...

Page 12: ...tch actuator and the air switch control box A small bead of silicone may be added to the air tubing connections to help prevent the tubing from disengaging The air switch tubing must also be installed...

Page 13: ...and the air switch control box A small bead of silicone may be added to the air tubing connections to help prevent the tubing from disengaging The air switch tubing must also be installed to allow fo...

Page 14: ...cont WHIRLPOOL WP SYSTEM This Whirlpool bath is provided with an Air On Off switch The tubing should be firmly attached to the bath s air switch actuator and the pump air switch connection A small bea...

Page 15: ...d Check voltage at motor when control is on If no voltage control is defective b Make sure plug is fully inserted into the control box outlet c Check and reconnect if necessary Equipment does not manu...

Page 16: ...serves the right to substitute new or improved equipment on any replacements The repair or replacement of equipment shall be F O B point of shipment This warranty shall not apply to any merchandise wh...