background image

© 2021 Jason® Hydrotherapy  • 501.771.4477

Page 1 of 28

Customer Service :  800.255.5766

“TO BE REMOVED FOR USE BY THE OCCUPANT.”

49-1020-003

Date   05/2021

OWNER’S MANUAL

forma

®

 and Designer Collection Baths  

INSTALLATION, OPERATION, AND MAINTENANCE

Jason

®

 Hydrotherapy

 

8328 MacArthur Drive

North Little Rock, AR 72118

www.jasoninternational.com

MADE IN THE U.S.A.

 

OWNER’S RECORD

Dealer: 

Date Purchased: 

Date Installed: 

Installer: 

PLACE SERIAL NUMBER CARD WITH 

PRODUCT CONFIGURATION IN THIS BOX

INSPECTION

Inspect the unit prior to installation.  In the event of a 

problem, DO NOT install the unit.

All components are factory assembled to the bath and the 

unit is water tested and inspected prior to leaving Jason 

International, Inc.

NOTE: Transportation and insurance from Jason’s 

factory are the buyer’s responsibility.

Damage sustained in transit is the responsibility of 

the carrier.

  If damage is discovered, the carrier must 

be immediately notified in writing with a request for a 

representative to inspect the unit.  Failure of the carrier 

to respond should be reported to the seller and carrier.  

Always file a freight claim promptly.

The installer is responsible for insuring that the unit is 

free from defects or shipping damage.  

In the event of a 

problem, DO NOT install the unit.

Jason

®

 Hydrotherapy is not responsible for damage that 

might have been avoided by inspection or testing prior to 

installation.
Damage to the unit during installation will not be covered 

by warranty and is the responsibility of the installer.

If the carton shows sign of damage, inspect 

the product before accepting and describe the 

problem on the Bill of Lading.

ALL WARRANTY CLAIMS ON ACRYLIC SURFACE 

DAMAGE MUST BE MADE PRIOR TO INSTALLATION. 

Inspect plumbing and bath surface for missing or damaged 

components. Alert your dealer of any discrepancies. 
To protect the unit from damage keep the bath in the 

carton until ready for installation.

EQUIPMENT ACCESS

In accordance with Building Codes, service access to 

all hydrotherapy bath equipment, controls and electrical 

connections must be provided during installation 

(Recommended minimum 28” x 17” [71 x 43 cm]). 

Insufficient access will hinder repair and maintenance. 

Warranty service will not cover costs of providing 

equipment access.
The Specification Sheet for this bath contains additional 

technical information.  This sheet can be provided by your 

dealer or accessed online at www.jasoninternational.com.

Summary of Contents for KT525 SR

Page 1: ...romptly The installer is responsible for insuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason Hydrotherapy is not responsible for dama...

Page 2: ...2021 Jason Hydrotherapy 501 771 4477 Page 2 of 28 Customer Service 800 255 5766 NOTES...

Page 3: ...timulants antihistamines vasoconstric tors vasodilators hypnotics narcotics or tranquilizers F Lower water temperatures are recommended for extended use exceeding 10 15 minutes and for young children...

Page 4: ...es et pour les jeunes enfants F Puisque les temp ratures excessives ont un potentiel lev pour les f tus durant les premiers mois de la grossesse les femmes enceintes ou possiblement enceintes doivent...

Page 5: ...cant DANGER Ne pas modifier le c blage install en usine Tous les mat riaux de construction et c blage doivent tre loi gn s de toutes sources de chaleur moduites par le abin ATTENTION Garder les cheveu...

Page 6: ...Trouble Shooting Guide section of this manual If the unit still fails to operate and is out of warranty contact an authorized service technician for repair If the unit is within the warranty period co...

Page 7: ...ature sensors and Jason s Bluetooth Sound Immersion system WHIRLPOOL FEATURES Jason s Whirlpool hydrotherapy bath utilizes Perfect Pressure Perfect Flow jets that are directed at key muscle groups all...

Page 8: ...ONS cont STANDARD EDITION ELECTRONIC CONTROLS ICONS POWER Icon WHIRLPOOL Icon WP MW AW AIRMASSEUR Icon AM MA AW MICROSILK Icon MS MW MA LED Icon Optional PILLOW Icon Optional WP MW AW Blower SPEED Ico...

Page 9: ...een all the colors A single press of the icon will progress the light to the next mode or color Press and hold the icon to cycle through the FADE mode release the icon to choose any custom color Order...

Page 10: ...solid GREEN This purge cycle can be canceled by pressing and holding the power button for five 5 seconds Starting the AirMasseur will turn OFF any other therapy equipment running at that time MicroSi...

Page 11: ...t in timer shuts off the therapy equipment twenty 20 minutes after being activated Customized User Settings Menu The Signature Edition system offers many features that can be customized through the Se...

Page 12: ...the six 6 buttons will begin to light Press the illuminated button to proceed to the next icon The LED light will be tested next Select the check mark to verify the appropriate Red Green or Blue color...

Page 13: ...can be canceled by selecting the CANCEL button Starting the AirMasseur will turn OFF any other therapy equipment running at that time The PILLOW icon is used to activate the neck jets when the Jetted...

Page 14: ...h thoroughly after cleaning SURFACE MAINTENANCE Area with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e No vus Plastic Polish No 2 available at...

Page 15: ...aining To verify use a level on top of the deck on both ends and front of the bath Jason baths are designed to be support ed at the base of the bath If the floor is smooth and level the bath s Level F...

Page 16: ...the area of intended installa tion cut the equipment support strap s to allow the equip ment to rest firmly level with the bottom of the bath on the floor We recommend securing the equipment mounts t...

Page 17: ...air inlet of the bath Choose a loca tion as close as possible to the bath to ensure maximum efficiency 1 The installer must determine the layout of the piping exact remote mount location and service...

Page 18: ...and exposed metal in the area as may be required by local code Note The air blower s exterior housing is made of all plastic ma terials and does not require a bonding conductor Grounding is required...

Page 19: ...ICL 297 Female Nema Load Connections Not Used Ozone Male Nema Line Connection Keypad IDU 264 LED Cable CBL 366 LED Cable CBL 366 Keypad Cable CBL 372 WP Pump Male Nema Line Connection To Dedicated 120...

Page 20: ...Bluetooth Sound Immersion Included on Signature Edition AIRMASSEUR AM SYSTEM Notes Asinglededicated120v 60hz20AGFCI protected service is required for all bath equipment Additional options may require...

Page 21: ...372 WP Pump To Dedicated 120V 60Hz 20A GFCI Protected Service LWL Temp Sensor ITW 209 1 2 Male Nema Line Connection Blower Male Nema Line Connection To Dedicated 120V 60Hz 20A GFCI Protected Service...

Page 22: ...ted120v 60hz20AGFCI protected service is required for all bath equipment Additional options may require multi ple outlets be installed on the single service Optional Thermo Comfort Surface Heater Heat...

Page 23: ...L Temp Sensor ITW 209 1 2 Male Nema Line Connection Male Nema Line Connection To Dedicated 120V 60Hz 20A GFCI Protected Service Heater MS Pump TRANSDUCER BLACK RED BLACK RED BLUETOOTH AMPLIFIER Option...

Page 24: ...Male Nema Line Connection Light ASW Display ICL Light Water Detect Power LED Config Switch Load 2 Load 1 LEDs ICL 297 Female Nema Load Connections Ozone Male Nema Line Connection Keypad IDU 264 LED C...

Page 25: ...2021 Jason Hydrotherapy 501 771 4477 Page 25 of 28 Customer Service 800 255 5766 NOTES...

Page 26: ...ers and GFCI if tripped Check fuses and replace if bad Check voltage at motor when control is on If no voltage control is defective b Make sure plug is fully inserted into the control box outlet c Che...

Page 27: ...er recently using the bathtub and its equipment b Purge cycle has started with no apparent warning a No action is needed This is a normal feature to help keep the air channel dry and sanitary b Follow...

Page 28: ...e free from defects in workmanship and materials as provided in the enclosed Warranty Statement and Warranty validation card The pre addressed warranty registration card MUST be filled out by the purc...

Reviews: