background image

© 2021 Jason® Hydrotherapy  • 501.771.4477

Page 6 of 28

Customer Service :  800.255.5766

FEATURES, CONTROLS AND OPERATING INSTRUCTIONS (cont.)

FEATURES, CONTROLS AND OPERATING INSTRUCTIONS

INTRODUCTION

This manual contains all of the information needed for 

the proper installation and operation for your Jason bath.  

The bath has been designed to give you years of relaxing 

trouble-free service, provided the unit is maintained and 

operated in accordance with these instructions.

Thoroughly clean and disinfect the unit as described in 

the CLEANING section of the 

USER MAINTENANCE 

INSTRUCTIONS 

section of this owner’s manual before its 

first use and periodically thereafter.

CAUTION:

 Keep hair, towels and clothing away from any 

installed suction fitting whenever the equipment is ON.  

Never operate the equipment with the suction cover off, 

doing so voids the manufacturer’s warranty—it is a safety 

cover designed to eliminate the potential of hair and body 

entrapment.

All Jason baths are pre-plumbed at the factory.

WARNING: Before operating, refer to the instructions 

at the beginning of this owner’s manual pertaining to 

the risk of fire, electric shock or injury to persons.

Filling and Draining

Close the drain and fill the bath with water to the desired 

level (at least two (2) inches (50mm) above the jet). The 

inlet temperature should not exceed 104°F (40°C). When 

bath is in use, turn the unit OFF before draining the water. 

The bath unit and its plumbing are designed to drain after 

each use whether used as a hydrotherapy bath, soaking 

bath, or just taking a shower.

NOTE:

 If the unit fails to operate, check the breaker panel 

to ensure that the circuit breaker is on. Check the GFCI by 

testing and resetting it. If the unit still fails to operate, refer 

to the Trouble Shooting Guide section of this manual. If the 

unit still fails to operate and is out of warranty, contact an 

authorized service technician for repair. If the unit is within 

the warranty period, contact JASON Technical Services 

at 800-255-5766. 

DO NOT ATTEMPT TO RESOLVE THE 

PROBLEM.

FEATURES 

Jason offers the finest in soaking hydrotherapy baths but 

also offers the option for more hydrotherapy choices with 

Jason MicroSilk

®

 or AirMasseur

®

 therapy units.  Please 

consult your product configuration label on the front of this 

manual to learn what hydrotherapy experiences await you.

MICROSILK

®

 FEATURES

Jason’s MicroSilk hydrotherapy bath supersaturates the 

water with negatively charged, oxygen-rich microbubbles 

which gives your skin new life. This results in increased 

oxygen levels which promotes healthy skin cell growth, 

neutralizes free radicals and encourages healing of scar 

tissue formation.

MicroSilk

®

 Unit

The MicroSilk unit generates the oxygen-rich microbubbles 

that fill the bath.  MicroSilk units provided on Jason baths 

are factory tested after installation on the bath.

MicroSilk

®

 Port

A strategically placed MicroSilk port is provided for com-

plete enjoyment of your bath.  The port can also be used to 

connect an optional MicroSilk Shower Wand.

Standard Edition MicroSilk

®

 

The Jason Standard Edition MicroSilk hydrotherapy 

includes the Microbubble Generator unit, an electronic 

control and a 20-minute timer.

Premier Edition MicroSilk

®

 

The Jason Premier Edition MicroSilk hydrotherapy pro-

vides all the features of the Standard Edition with the 

included benefits of a digital control with LCD-display 

readout, an LED Chromatherapy mood light, enhanced 

user control options and an Automatic Ozone Sanitation 

system.

Signature Edition MicroSilk

®

 

The Jason Signature Edition MicroSilk hydrotherapy pro-

vides all the benefits of the Premier Edition as well as low 

water/temperature sensors and Jason’s Bluetooth Sound 

Immersion system.

Summary of Contents for KT525 SR

Page 1: ...romptly The installer is responsible for insuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason Hydrotherapy is not responsible for dama...

Page 2: ...2021 Jason Hydrotherapy 501 771 4477 Page 2 of 28 Customer Service 800 255 5766 NOTES...

Page 3: ...timulants antihistamines vasoconstric tors vasodilators hypnotics narcotics or tranquilizers F Lower water temperatures are recommended for extended use exceeding 10 15 minutes and for young children...

Page 4: ...es et pour les jeunes enfants F Puisque les temp ratures excessives ont un potentiel lev pour les f tus durant les premiers mois de la grossesse les femmes enceintes ou possiblement enceintes doivent...

Page 5: ...cant DANGER Ne pas modifier le c blage install en usine Tous les mat riaux de construction et c blage doivent tre loi gn s de toutes sources de chaleur moduites par le abin ATTENTION Garder les cheveu...

Page 6: ...Trouble Shooting Guide section of this manual If the unit still fails to operate and is out of warranty contact an authorized service technician for repair If the unit is within the warranty period co...

Page 7: ...ature sensors and Jason s Bluetooth Sound Immersion system WHIRLPOOL FEATURES Jason s Whirlpool hydrotherapy bath utilizes Perfect Pressure Perfect Flow jets that are directed at key muscle groups all...

Page 8: ...ONS cont STANDARD EDITION ELECTRONIC CONTROLS ICONS POWER Icon WHIRLPOOL Icon WP MW AW AIRMASSEUR Icon AM MA AW MICROSILK Icon MS MW MA LED Icon Optional PILLOW Icon Optional WP MW AW Blower SPEED Ico...

Page 9: ...een all the colors A single press of the icon will progress the light to the next mode or color Press and hold the icon to cycle through the FADE mode release the icon to choose any custom color Order...

Page 10: ...solid GREEN This purge cycle can be canceled by pressing and holding the power button for five 5 seconds Starting the AirMasseur will turn OFF any other therapy equipment running at that time MicroSi...

Page 11: ...t in timer shuts off the therapy equipment twenty 20 minutes after being activated Customized User Settings Menu The Signature Edition system offers many features that can be customized through the Se...

Page 12: ...the six 6 buttons will begin to light Press the illuminated button to proceed to the next icon The LED light will be tested next Select the check mark to verify the appropriate Red Green or Blue color...

Page 13: ...can be canceled by selecting the CANCEL button Starting the AirMasseur will turn OFF any other therapy equipment running at that time The PILLOW icon is used to activate the neck jets when the Jetted...

Page 14: ...h thoroughly after cleaning SURFACE MAINTENANCE Area with minor scratches or dull surfaces can be restored by applying commercially available plastic polish i e No vus Plastic Polish No 2 available at...

Page 15: ...aining To verify use a level on top of the deck on both ends and front of the bath Jason baths are designed to be support ed at the base of the bath If the floor is smooth and level the bath s Level F...

Page 16: ...the area of intended installa tion cut the equipment support strap s to allow the equip ment to rest firmly level with the bottom of the bath on the floor We recommend securing the equipment mounts t...

Page 17: ...air inlet of the bath Choose a loca tion as close as possible to the bath to ensure maximum efficiency 1 The installer must determine the layout of the piping exact remote mount location and service...

Page 18: ...and exposed metal in the area as may be required by local code Note The air blower s exterior housing is made of all plastic ma terials and does not require a bonding conductor Grounding is required...

Page 19: ...ICL 297 Female Nema Load Connections Not Used Ozone Male Nema Line Connection Keypad IDU 264 LED Cable CBL 366 LED Cable CBL 366 Keypad Cable CBL 372 WP Pump Male Nema Line Connection To Dedicated 120...

Page 20: ...Bluetooth Sound Immersion Included on Signature Edition AIRMASSEUR AM SYSTEM Notes Asinglededicated120v 60hz20AGFCI protected service is required for all bath equipment Additional options may require...

Page 21: ...372 WP Pump To Dedicated 120V 60Hz 20A GFCI Protected Service LWL Temp Sensor ITW 209 1 2 Male Nema Line Connection Blower Male Nema Line Connection To Dedicated 120V 60Hz 20A GFCI Protected Service...

Page 22: ...ted120v 60hz20AGFCI protected service is required for all bath equipment Additional options may require multi ple outlets be installed on the single service Optional Thermo Comfort Surface Heater Heat...

Page 23: ...L Temp Sensor ITW 209 1 2 Male Nema Line Connection Male Nema Line Connection To Dedicated 120V 60Hz 20A GFCI Protected Service Heater MS Pump TRANSDUCER BLACK RED BLACK RED BLUETOOTH AMPLIFIER Option...

Page 24: ...Male Nema Line Connection Light ASW Display ICL Light Water Detect Power LED Config Switch Load 2 Load 1 LEDs ICL 297 Female Nema Load Connections Ozone Male Nema Line Connection Keypad IDU 264 LED C...

Page 25: ...2021 Jason Hydrotherapy 501 771 4477 Page 25 of 28 Customer Service 800 255 5766 NOTES...

Page 26: ...ers and GFCI if tripped Check fuses and replace if bad Check voltage at motor when control is on If no voltage control is defective b Make sure plug is fully inserted into the control box outlet c Che...

Page 27: ...er recently using the bathtub and its equipment b Purge cycle has started with no apparent warning a No action is needed This is a normal feature to help keep the air channel dry and sanitary b Follow...

Page 28: ...e free from defects in workmanship and materials as provided in the enclosed Warranty Statement and Warranty validation card The pre addressed warranty registration card MUST be filled out by the purc...

Reviews: