Jäspi VLK
Operating instructions
30
Technical table
Jäspi VLK
15
30
60
60-3
Declared tap profile
D
M
M
M
Standard efficiency
B
B
C
C
Water heating energy efficiency
%
35
35
37
37
Annual electricity consumption
kWh
527
528
1381
1381
Thermostat temperature - factory setting
°C
68
68
67
67
Volume
litres
15
30
60
60
Output 40 °C water
litres
21
35
72
72
Net weight without package and filler
kg
10.9
15.07
18.8
18.8
Required fuse
A
10
Voltage:
V (AC) 230V 1N PE 230V 1N PE 230V 1N PE
230 V 1N
PE: 1 kW /
400 V 2 PE:
3 kW
Enclosure rating
IPX4
Output
kW
2
2
2
3
Design pressure
Bar
10
Heating time to 45°C
h
0.3
0.6
1.2
0.8
Heating time to 80°C
h
0.6
1.2
2.4
1.6
Thermal energy content at 80°C
kWh
1.2
2.4
4.8
4.8
HVAC no.
5260130
5260131
5260132
5260133
Jäspi VLK
100
100-3
160
Declared tap profile
W
W
W
Standard efficiency
C
C
C
Water heating energy efficiency
%
37
37
37
Annual electricity consumption
kWh
2766
2766
4496
Thermostat temperature - factory setting
°C
67
67
65
Volume
litres
90
90
160
Output 40 °C water
litres
138.1
138.1
170
Net weight without package and filler
kg
25.5
25.5
37.1
Required fuse
A
Voltage:
V (AC) 230V 1N PE
230 V 1N
PE: 1 kW /
400 V 2 PE:
3 kW
230 V 1N
PE: 1 kW /
400 V 2 PE:
3 kW
Enclosure rating
Output
kW
2
3
3
Design pressure
Bar
Heating time to 45°C
h
2.0
1.4
2.2
Heating time to 80°C
h
4.0
2.7
4.3
Thermal energy content at 80°C
kWh
8.1
8.1
12.9
HVAC no.
5260134
5260135
5260136
Summary of Contents for VLK 15
Page 1: ...J SPI VLK FI K YTT OHJE SE BRUKSANVISNING EN OPERATING INSTRUCTIONS Kaukora Oy 2021...
Page 32: ...J spi VLK 32 Energiamerkinn t Energim rkning...
Page 33: ...J spi VLK 33...
Page 34: ...J spi VLK 34 Tuotteiden energiamerkinn t ladattavissa my s osoitteesta www j spi fi...
Page 35: ...J spi VLK 35...
Page 36: ...Kaukora Oy 2021 D115394 4...