background image

Service Guide 

JATCO Environmental Protection Tanks 

J-5000 SM-P 

2

00 

ABV

*INSTRUMENTATION GAS IS MANDATORY FOR SUPPLY GAS*

Listed below are a series of steps to follow if the JATCO tank fails to dump properly. 

The tank supply gas must have adequate 

volume

 and pressure. For best operation use 1” pipe for 

the tank supply gas plumed as close to the tank as possible. Then reduce down to the tubing 

connections 

(C)

 and 

(

J

)

 on the JATCO tank.  

Be sure there is an adequate supply of volume and gas pressure (70-75 psi), to the inlet 

connection on the level control

ler

 

(

C

)

, and (

2

00psi

 max

) to the 3-way ball valve supply 

(

J

)

. If 

there is enough pressure at the supply connections, press down on the manual dump plunger 

(F)

. This should cause the tank to manually dump, then vent through 

(H)

 when the cycle is 

complete. If the JATCO tank fails to dump manually, remove pilot signal connector tubing to 3-

way ball valve’s actuator 

(G)

 to test for pilot signal from level control 

(D)

. If the level control is 

not sending a pilot signal to the actuator when depressing manual dump plunger, removal and or 

inspection of level control will be necessary and proceed to next step. If pilot signal pressure is 

present but actuator fails to operate, usually the pilot signal will escape from the actuator vent 

orifice. This indicates O-ring failure in the actuator and replacement may be necessary. The 

actuator does have a repair kit mainly consisting of O-rings.

Step #2 the side mount level controller has very few moving parts. If the valve is not operating 
properly, remove and inspect travel of float arm. If no obstruction is visually present but the 
float arm does not travel freely then removal of float arm is necessary. To remove float arm 
carefully drive float arm retaining pin out with a hammer and punch. Then inspect magnet and 
chamber for debris. If there is no obstruction with float arm assembly or tubing connections, 
replacement may be necessary.  

244 NW 111th   •   Oklahoma City, Ok. 73114 •  405/755-4100 •  405/755-4101 Fax 

244 NW 111th   •   Oklahoma City, Ok. 73114 •  405/755-4100 •  405/755-4101 Fax 