DTC P0710 A/T FLUID TEMPERATURE SENSOR CIRCUIT
AT-121
[RE4F04B]
D
E
F
G
H
I
J
K
L
M
A
B
AT
Revision: November 2006
2006 Altima
5.
DETECT MALFUNCTIONING ITEM
1.
Remove oil pan.
2.
Check the following items:
–
A/T fluid temperature sensor
Check resistance between two terminals while changing temper-
ature as shown in figure.
–
Harness of terminal cord assembly for short or open
OK or NG
OK
>> GO TO 7.
NG
>> Repair or replace damaged parts.
6.
CHECK INPUT SIGNAL OF A/T FLUID TEMPERATURE SENSOR (WITHOUT CONSULT-II)
Without CONSULT-II
1.
Start engine.
2.
Check voltage between TCM terminal 47 and ground while
warming up A/T.
OK or NG
OK
>> GO TO 7.
NG
>> GO TO 3.
7.
CHECK DTC
Perform
AT-116, "Diagnostic Trouble Code (DTC) Confirmation Procedure"
OK or NG
OK
>> INSPECTION END
NG
>> GO TO 8.
8.
CHECK TCM INSPECTION
1.
Perform TCM input/output signal inspection.
2.
If NG, recheck TCM pin terminals for damage or loose connection with harness connector.
OK or NG
OK
>> INSPECTION END
NG
>> Repair or replace damaged parts.
Temperature
Resistance (Approx.)
20 (68)
25k
Ω
80 (176)
0.3k
Ω
SAT298F
Temperature
Voltage (Approx.)
Cold [20
°
C (68
°
F)]
→
Hot [80
°
C (176
°
F)]
1.5V
→
0.5V
WCIA0462E